Ignore:
Timestamp:
Sep 23, 2009 9:40:33 AM (15 years ago)
Author:
raasch
Message:

in-situ AND potential density are calculated and used in the ocean version

File:
1 edited

Legend:

Unmodified
Added
Removed
  • palm/trunk/SOURCE/CURRENT_MODIFICATIONS

    r377 r388  
    125125Errors:
    126126------
     127Bugfix: Initial hydrostatic pressure profile in case of ocean runs is now
     128calculated in 5 iteration steps. (init_ocean)
     129
     130Bugfix: wrong sign in buoyancy production of ocean part in case of not using
     131the reference density (only in 3D routine production_e) (production_e)
     132
    127133Bugfix: output of averaged 2d/3d quantities requires that an avaraging
    128134interval has been set, respective error message is included (check_parameters)
     
    183189Bugfix: initial setting of time_coupling in coupled restart runs (time_integration)
    184190
    185 advec_particles, check_parameters, cpu_log, data_output_2d, data_output_3d, header, init_3d_model, init_particles, modules, netcdf, prandtl_fluxes, production_e, read_var_list, time_integration, user_last_actions, write_var_list
     191advec_particles, check_parameters, cpu_log, data_output_2d, data_output_3d, header, init_3d_model, init_particles, init_ocean, modules, netcdf, prandtl_fluxes, production_e, read_var_list, time_integration, user_last_actions, write_var_list
Note: See TracChangeset for help on using the changeset viewer.