94 | | ||Nested simulation ||03/09/2020 || || Concentration of chemical compounds reached unrealistic values. Simulation is on hold until the reason is identified and the issue is fixed. || |
| 94 | ||Nested simulation ||03/09/2020 ||01/10/2020 || Concentration of chemical compounds reached unrealistic values. This was caused by an error within the offline nesting. || |
| 95 | ||Nested simulation ||01/10/2020 ||07/10/2020 || Bug within the indoor model during spinup detected and fixed. || |
| 96 | ||Nested simulation ||07/10/2020 ||- || Update of simulation setup after discussion with the evaluation working group and Module B. Now two child domains are simulated (ERP and Steglitz). || |
| 97 | ||Nested simulation ||14/10/2020 ||30/10/2020 || Further bugs detected within the indoor model and the driver setup fixed. || |
| 98 | ||Nested simulation ||02/11/2020 ||- || Further updates of the simulation setup due to performance imbalance between parent and child. Child domains were extended and now cover more measurements (discussed with Module B). || |
| 99 | ||Nested simulation ||03/11/2020 ||13/11/2020 || Bugs and outdated data in building surface parameters fixed/updated. || |
| 100 | ||Nested simulation ||13/11/2020 ||19/11/2020 || Reading restart data takes more time than the actual simulation when using MPI shared memory method. Debugging started. For now, switching back to old restart mechanism. || |
| 101 | ||Nested simulation ||27/11/2020 ||03/12/2020 || Error/missing input data for bio-meteorology module created crash during simulation. Bugs are temporarily fixed. || |
| 102 | ||Nested simulation ||30/11/2020 || || Error in photolysis scheme: Module B detected that there is only a simple scheme available without accounting for shadowing. Simulation is on hold until discussed if higher order scheme can be used instead. || |
| 103 | ||Nested simulation ||02/12/2020 || || Building setup needs further update: air conditioning for office buildings constructed before 2000 must be turned off to give more realistic waste-heat fluxes in Berlin. || |