HTCM output
This page is part of the Human Thermal Comfort Module (HTCM) documentation. It contains a documentation about the output of the human thermal comfort module.
For an overview of all HTCM-related pages, see the HTCM main page.
The output by the thermal comfort part of the biometeorology module is mostly (except for bio_mrt) two dimensional and is provided for the cell layer closest to 1.1 m above ground level. All parameters are available for instantaneous and time-averaged input. A list of output quantities can be found below.
Output is written to a 2d xy file, where only the layer z=0 will be used.
For all revisions < 3742:
If output is desired for a thermal index with averaged input and at least one of its input parameters 'pt_av', 'q_av', 'u_av', 'v_av' or 'w_av', please always state the 'bio_<index>*_xy_av' quantities after 'pt_av', 'q_av', 'u_av', 'v_av' and 'w_av' in 'data_output'! If not, they might become averaged twice.
To enable the output of the given quantity, please add
Quantity name | Meaning | Unit | input type (instantaneous or averaged) | output file (2d or 3d) |
---|---|---|---|---|
'bio_perct*_xy' | Perceived Temperature | °C | instantanious input | 2d (xy) file |
'bio_pet*_xy' | Physiologically Equivalent Temperature | °C | instantanious input | 2d (xy) file |
'bio_utci*_xy' | Universal Thermal Climate Index | °C | instantanious input | 2d (xy) file |
'bio_perct*_xy_av' | Perceived Temperature | °C | averaged input | 2d (xy) file |
'bio_pet*_xy_av' | Physiologically Equivalent Temperature | °C | averaged input | 2d (xy) file |
'bio_utci*_xy_av' | Universal Thermal Climate Index | °C | averaged input | 2d (xy) file |
to the data_output section.
The output of the thermal comfort calculation for agents is stored within the agents output quantities (*_agt files). Each agent thereby has its own field "ipt" holding the instationary index iPT.