Ignore:
Timestamp:
May 30, 2007 9:18:47 AM (18 years ago)
Author:
raasch
Message:

New:
---
Calculation and output of user-defined profiles. New &userpar parameters data_output_pr_user and max_pr_user.

check_parameters, flow_statistics, modules, parin, read_var_list, user_interface, write_var_list

Changed:


Division through dt_3d replaced by multiplication of the inverse. For performance optimisation, this is done in the loop calculating the divergence instead of using a seperate loop. (pres.f90) var_hom and var_sum renamed pr_palm.

data_output_profiles, flow_statistics, init_3d_model, modules, parin, pres, read_var_list, run_control, time_integration

Errors:


Bugfix: work_fft*_vec removed from some PRIVATE-declarations (poisfft).

Bugfix: field_chr renamed field_char (user_interface).

Bugfix: output of use_upstream_for_tke (header).

header, poisfft, user_interface

File:
1 edited

Legend:

Unmodified
Added
Removed
  • palm/trunk/DOC/app/chapter_3.5.1.html

    r62 r90  
    11<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
    22<html><head>
    3 <meta http-equiv="CONTENT-TYPE" content="text/html; charset=windows-1252"><title>PALM
    4 chapter 3.5.1</title> <meta name="GENERATOR" content="StarOffice 7 (Win32)"> <meta name="AUTHOR" content="Siegfried Raasch"> <meta name="CREATED" content="20040802;11451548"> <meta name="CHANGED" content="20041112;14401801"> <meta name="KEYWORDS" content="parallel LES model"> <style>
     3<meta http-equiv="CONTENT-TYPE" content="text/html; charset=windows-1252"><title>PALM chapter 3.5.1</title> <meta name="GENERATOR" content="StarOffice 7 (Win32)"> <meta name="AUTHOR" content="Siegfried Raasch"> <meta name="CREATED" content="20040802;11451548"> <meta name="CHANGED" content="20041112;14401801"> <meta name="KEYWORDS" content="parallel LES model"> <style>
    54<!--
    65@page { size: 21cm 29.7cm }
     
    204203quantities can be computed here. Also, additional time series
    205204quantities can be calculated. They have to be defined before in routine
    206 <a href="#user_init"><span style="font-family: Courier New,Courier,monospace;">user_init</span></a>.
    207 The routine is called once for each defined statistic region (see <a href="chapter_4.1.html#statistic_region">statistic_region</a>).</p><p></p><p>The
     205<a style="font-family: monospace;" href="#user_init">user_init</a>.
     206The routine is called once for each defined statistic region (see <a href="chapter_4.1.html#statistic_region">statistic_region</a>).</p><p>The
    208207routine contains some simple examples (as comment lines) in order to
    209 demonstrate how to use it.</p><p><br>Profiles have to
    210 be written to
    211 the array <tt><font style="font-size: 10pt;" size="2">sums</font></tt>.
    212 Please use profile numbers starting from 70 upward (thus e.g. <tt><font style="font-size: 10pt;" size="2">sums (&hellip;,
    213 60) =</font></tt><font style="font-size: 10pt;" size="2">&hellip;)</font>. These additional
     208demonstrate how to use it.<br><br>Profile sums have to
     209be stored in
     210the array <tt><font style="font-size: 10pt;" size="2">sums_l</font></tt>.&nbsp;The profile identification number (second index of array <span style="font-family: monospace;">sums_l</span>) must be within the range [<span style="font-family: monospace;"> pr_palm+1 , pr_palm+max_pr_user</span> ], where <span style="font-family: monospace;">pr_palm</span> is an internal parameter and&nbsp; <span style="font-family: Courier New,Courier,monospace;">max_pr_user</span> is the number of&nbsp;user-defined profiles as given by parameter <a href="http://www.muk.uni-hannover.de/%7Eraasch/PALM_group/doc/app/chapter_4.3.html#data_output_pr_user">data_output_pr_user</a> in the respective PALM run.</p><p> These additional
    214211profiles
    215 are temporally averaged in <tt><font style="font-size: 10pt;" size="2">flow_statistics</font></tt>.</p> </td>
     212are further processed (e.g. temporally averaged), like the standard profiles, in <tt><font style="font-size: 10pt;" size="2">flow_statistics</font></tt>.</p> </td>
    216213</tr> <tr><td style="vertical-align: top;">End
    217214of <span style="font-family: monospace;">check_parameters.f90</span>
    218 where output quantities are checked</td><td style="vertical-align: top;"><span style="font-family: monospace;"><a name="user_check_data_output"></a>user_check_data_<br>output(
    219 variable, unit )</span></td><td style="vertical-align: top;">Here the <span style="font-family: monospace;">unit</span>(s) of
    220 user-defined output quantities (see <a href="chapter_4.3.html#data_output_user">data_output_user</a>)
     215where 2d/3d output quantities are checked</td><td style="vertical-align: top;"><span style="font-family: monospace;"><a name="user_check_data_output"></a>user_check_data_<br>output(
     216variable, unit )</span></td><td style="vertical-align: top;">Here the physical <span style="font-family: monospace;">unit</span>(s) of
     217user-defined 2d/3d output quantities (see <a href="chapter_4.3.html#data_output_user">data_output_user</a>)
    221218have to be set. Input parameter <span style="font-family: monospace;">variable</span>
    222219contains the string identifier of the respective variable. For those
     220variables not recognized by the user, the parameter <span style="font-family: monospace;">unit</span> is set to
     221"illegal", which tells the calling routine that the output variable is
     222not defined and leads to a program abort.<br><br>See <a href="chapter_3.5.4.html">chapter 3.5.4</a> about
     223creating user-defined output quantities.</td></tr><tr><td style="vertical-align: top;">End
     224of <span style="font-family: monospace;">check_parameters.f90</span>
     225where vertical profile output quantities are checked</td><td style="vertical-align: top;"><a name="user_check_data_output_pr"></a><br><span style="font-family: monospace;">user_check_data_</span><br style="font-family: monospace;"><span style="font-family: monospace;">output_pr(</span><br style="font-family: monospace;"><span style="font-family: monospace;">variable, var_count, unit )</span></td><td style="vertical-align: top;">Here the physical <span style="font-family: monospace;">unit</span>(s) and vertical grid (u- or w-grid) of
     226user-defined vertical profile output quantities (see <a href="chapter_4.3.html#data_output_pr_user">data_output_pr_user</a>)
     227have to be set. Input parameter <span style="font-family: monospace;">variable</span>
     228contains the string identifier of the respective variable. Parameter<span style="font-family: monospace;"> var_count </span>contains the internal profile number and must not be changed by the user. For those
    223229variables not recognized by the user, the parameter <span style="font-family: monospace;">unit</span> is set to
    224230"illegal", which tells the calling routine that the output variable is
Note: See TracChangeset for help on using the changeset viewer.