Changeset 75 for palm/trunk/SOURCE/header.f90
- Timestamp:
- Mar 22, 2007 9:54:05 AM (17 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
palm/trunk/SOURCE/header.f90
r63 r75 5 5 ! ----------------- 6 6 ! Output of netcdf_64bit_3d, particles-package is now part of the default code, 7 ! output of the loop optimization method. 7 ! output of the loop optimization method, moisture renamed humidity, 8 ! output of subversion revision number 8 9 ! 9 10 ! Former revisions: … … 52 53 CHARACTER (LEN=10) :: coor_chr, host_chr 53 54 CHARACTER (LEN=16) :: begin_chr 55 CHARACTER (LEN=21) :: ver_rev 54 56 CHARACTER (LEN=40) :: output_format 55 57 CHARACTER (LEN=70) :: char1, char2, coordinates, gradients, dopr_chr, & … … 95 97 !-- Run-identification, date, time, host 96 98 host_chr = host(1:10) 97 WRITE ( io, 100 ) version, TRIM( run_classification ), run_date, & 99 ver_rev = TRIM( version ) // ' ' // TRIM( revision ) 100 WRITE ( io, 100 ) ver_rev, TRIM( run_classification ), run_date, & 98 101 run_identifier, run_time, runnr, ADJUSTR( host_chr ) 99 102 #if defined( __parallel ) … … 217 220 WRITE ( io, 123 ) rayleigh_damping_height, rayleigh_damping_factor 218 221 ENDIF 219 IF ( moisture) THEN222 IF ( humidity ) THEN 220 223 IF ( .NOT. cloud_physics ) THEN 221 224 WRITE ( io, 129 ) … … 370 373 ENDIF 371 374 372 IF ( moisture.OR. passive_scalar ) THEN373 IF ( moisture) THEN375 IF ( humidity .OR. passive_scalar ) THEN 376 IF ( humidity ) THEN 374 377 IF ( ibc_q_b == 0 ) THEN 375 378 runten = 'q(0) = q_surface' … … 405 408 IF ( random_heatflux ) WRITE ( io, 307 ) 406 409 ENDIF 407 IF ( moisture.AND. constant_waterflux ) THEN410 IF ( humidity .AND. constant_waterflux ) THEN 408 411 WRITE ( io, 311 ) surface_waterflux 409 412 ENDIF … … 418 421 WRITE ( io, 306 ) top_heatflux 419 422 ENDIF 420 IF ( moisture.OR. passive_scalar ) THEN423 IF ( humidity .OR. passive_scalar ) THEN 421 424 WRITE ( io, 315 ) 422 425 ENDIF … … 426 429 WRITE ( io, 305 ) zu(1), roughness_length, kappa, rif_min, rif_max 427 430 IF ( .NOT. constant_heatflux ) WRITE ( io, 308 ) 428 IF ( moisture.AND. .NOT. constant_waterflux ) THEN431 IF ( humidity .AND. .NOT. constant_waterflux ) THEN 429 432 WRITE ( io, 312 ) 430 433 ENDIF … … 955 958 !-- Initial humidity profile 956 959 !-- Building output strings, starting with surface humidity 957 IF ( moisture.OR. passive_scalar ) THEN960 IF ( humidity .OR. passive_scalar ) THEN 958 961 WRITE ( temperatures, '(E8.1)' ) q_surface 959 962 gradients = '--------' … … 978 981 ENDDO 979 982 980 IF ( moisture) THEN983 IF ( humidity ) THEN 981 984 WRITE ( io, 421 ) TRIM( coordinates ), TRIM( temperatures ), & 982 985 TRIM( gradients ), TRIM( slices ) … … 1021 1024 WRITE ( io, 475 ) pt_surface_initial_change 1022 1025 ENDIF 1023 IF ( moisture.AND. q_surface_initial_change /= 0.0 ) THEN1026 IF ( humidity .AND. q_surface_initial_change /= 0.0 ) THEN 1024 1027 WRITE ( io, 476 ) q_surface_initial_change 1025 1028 ENDIF … … 1113 1116 1114 1117 99 FORMAT (1X,78('-')) 1115 100 FORMAT (/1 0X,'****************',11X,28('-')/&1116 1 0X,'* ',A12,'*',11X,A/&1117 1 0X,'****************',11X,28('-')//&1118 100 FORMAT (/1X,'*************************',11X,28('-')/ & 1119 1X,'* ',A,' *',11X,A/ & 1120 1X,'*************************',11X,28('-')// & 1118 1121 ' Date: ',A8,11X,'Run: ',A20/ & 1119 1122 ' Time: ',A8,11X,'Run-No.: ',I2.2/ &
Note: See TracChangeset
for help on using the changeset viewer.