Ignore:
Timestamp:
Jul 12, 2016 4:34:24 PM (8 years ago)
Author:
suehring
Message:

Separate balance equations for humidity and passive_scalar

File:
1 edited

Legend:

Unmodified
Added
Removed
  • palm/trunk/SOURCE/read_var_list.f90

    r1958 r1960  
    1919! Current revisions:
    2020! ------------------
    21 !
     21! Separate humidity and passive scalar
     22! Remove unused variables from ONLY list
    2223!
    2324! Former revisions:
     
    175176    USE arrays_3d,                                                             &
    176177        ONLY:  inflow_damping_factor, mean_inflow_profiles, pt_init,           &
    177                q_init, ref_state, sa_init, u_init, ug, v_init, vg
     178               q_init, ref_state, s_init, sa_init, u_init, ug, v_init, vg
    178179
    179180    USE control_parameters
     
    292293       ALLOCATE( ug(0:nz+1), u_init(0:nz+1), vg(0:nz+1),                       &
    293294                 v_init(0:nz+1), pt_init(0:nz+1), q_init(0:nz+1),              &
    294                  ref_state(0:nz+1), sa_init(0:nz+1),                           &
     295                 ref_state(0:nz+1), s_init(0:nz+1), sa_init(0:nz+1),           &
    295296                 hom(0:nz+1,2,pr_palm+max_pr_user,0:statistic_regions),        &
    296297                 hom_sum(0:nz+1,pr_palm+max_pr_user,0:statistic_regions) )
     
    486487          CASE ( 'mean_inflow_profiles' )
    487488             IF ( .NOT. ALLOCATED( mean_inflow_profiles ) )  THEN
    488                 ALLOCATE( mean_inflow_profiles(0:nz+1,6) )
     489                ALLOCATE( mean_inflow_profiles(0:nz+1,7) )
    489490             ENDIF
    490491             READ ( 13 )  mean_inflow_profiles
     
    597598          CASE ( 'run_coupled' )
    598599             READ ( 13 )  run_coupled
     600          CASE ( 's_init' )
     601             READ ( 13 )  s_init
     602          CASE ( 's_surface' )
     603             READ ( 13 )  s_surface
     604          CASE ( 's_surface_initial_change' )
     605             READ ( 13 )  s_surface_initial_change
     606          CASE ( 's_vertical_gradient' )
     607             READ ( 13 )  s_vertical_gradient
     608          CASE ( 's_vertical_gradient_level' )
     609             READ ( 13 )  s_vertical_gradient_level
     610          CASE ( 's_vertical_gradient_level_ind' )
     611             READ ( 13 )  s_vertical_gradient_level_ind
    599612          CASE ( 'sa_init' )
    600613             READ ( 13 )  sa_init
     
    617630          CASE ( 'surface_waterflux' )
    618631             READ ( 13 )  surface_waterflux     
    619           CASE ( 's_surface' )
    620              READ ( 13 )  s_surface
    621           CASE ( 's_surface_initial_change' )
    622              READ ( 13 )  s_surface_initial_change
    623           CASE ( 's_vertical_gradient' )
    624              READ ( 13 )  s_vertical_gradient
    625           CASE ( 's_vertical_gradient_level' )
    626              READ ( 13 )  s_vertical_gradient_level
    627632          CASE ( 'time_coupling' )
    628633             READ ( 13 )  time_coupling
     
    789794
    790795    USE arrays_3d,                                                             &
    791         ONLY:  inflow_damping_factor, mean_inflow_profiles, pt_init,           &
    792                q_init, ref_state, sa_init, u_init, ug, v_init, vg
     796        ONLY:  inflow_damping_factor, mean_inflow_profiles, ref_state, ug, vg
    793797
    794798    USE control_parameters
Note: See TracChangeset for help on using the changeset viewer.