Ignore:
Timestamp:
Apr 5, 2016 1:12:47 PM (8 years ago)
Author:
raasch
Message:

bugfix for r1797: zero setting of temperature within topography does not work and has been disabled

File:
1 edited

Legend:

Unmodified
Added
Removed
  • palm/trunk/SOURCE/pmc_interface.f90

    r1798 r1801  
    2020! Current revisions:
    2121! ------------------
    22 !
     22! bugfix for r1797: zero setting of temperature within topography does not work
     23! and has been disabled
    2324!
    2425! Former revisions:
     
    31793180                   w(nzb:nzb_w_inner(j,i),j,i)  = 0.0_wp
    31803181                   e(nzb:nzb_s_inner(j,i),j,i)  = 0.0_wp
    3181                    pt(nzb:nzb_s_inner(j,i),j,i) = 0.0_wp
    3182                    IF ( humidity  .OR.  passive_scalar )  THEN
    3183                       q(nzb:nzb_s_inner(j,i),j,i) = 0.0_wp
    3184                    ENDIF
     3182!
     3183!--                TO_DO: zero setting of temperature within topography creates
     3184!--                       wrong results
     3185!                   pt(nzb:nzb_s_inner(j,i),j,i) = 0.0_wp
     3186!                   IF ( humidity  .OR.  passive_scalar )  THEN
     3187!                      q(nzb:nzb_s_inner(j,i),j,i) = 0.0_wp
     3188!                   ENDIF
    31853189                ENDDO
    31863190             ENDDO
Note: See TracChangeset for help on using the changeset viewer.