Ignore:
Timestamp:
Mar 8, 2013 11:54:10 PM (12 years ago)
Author:
raasch
Message:

New:
---

GPU porting of pres, swap_timelevel. Adjustments of openACC directives.
Further porting of poisfft, which now runs completely on GPU without any
host/device data transfer for serial an parallel runs (but parallel runs
require data transfer before and after the MPI transpositions).
GPU-porting of tridiagonal solver:
tridiagonal routines split into extermal subroutines (instead using CONTAINS),
no distinction between parallel/non-parallel in poisfft and tridia any more,
tridia routines moved to end of file because of probable bug in PGI compiler
(otherwise "invalid device function" is indicated during runtime).
(cuda_fft_interfaces, fft_xy, flow_statistics, init_3d_model, palm, poisfft, pres, prognostic_equations, swap_timelevel, time_integration, transpose)
output of accelerator board information. (header)

optimization of tridia routines: constant elements and coefficients of tri are
stored in seperate arrays ddzuw and tric, last dimension of tri reduced from 5 to 2,
(init_grid, init_3d_model, modules, palm, poisfft)

poisfft_init is now called internally from poisfft,
(Makefile, Makefile_check, init_pegrid, poisfft, poisfft_hybrid)

CPU-time per grid point and timestep is output to CPU_MEASURES file
(cpu_statistics, modules, time_integration)

Changed:


resorting from/to array work changed, work now has 4 dimensions instead of 1 (transpose)
array diss allocated only if required (init_3d_model)

pressure boundary condition "Neumann+inhomo" removed from the code
(check_parameters, header, poisfft, poisfft_hybrid, pres)

Errors:


bugfix: dependency added for cuda_fft_interfaces (Makefile)
bugfix: CUDA fft plans adjusted for domain decomposition (before they always
used total domain) (fft_xy)

File:
1 edited

Legend:

Unmodified
Added
Removed
  • palm/trunk/SOURCE/check_parameters.f90

    r1104 r1111  
    2020! Current revisions:
    2121! -----------------
    22 !
     22! ibc_p_b = 2 removed
    2323!
    2424! Former revisions:
     
    16011601    ELSEIF ( bc_p_b == 'neumann' )  THEN
    16021602       ibc_p_b = 1
    1603     ELSEIF ( bc_p_b == 'neumann+inhomo' )  THEN
    1604        ibc_p_b = 2
    16051603    ELSE
    16061604       message_string = 'unknown boundary condition: bc_p_b = "' // &
     
    16081606       CALL message( 'check_parameters', 'PA0059', 1, 2, 0, 6, 0 )
    16091607    ENDIF
    1610     IF ( ibc_p_b == 2  .AND.  .NOT. prandtl_layer )  THEN
    1611        message_string = 'boundary condition: bc_p_b = "' // TRIM( bc_p_b ) // &
    1612                         '" not allowed with prandtl_layer = .FALSE.'
    1613        CALL message( 'check_parameters', 'PA0060', 1, 2, 0, 6, 0 )
    1614     ENDIF
     1608
    16151609    IF ( bc_p_t == 'dirichlet' )  THEN
    16161610       ibc_p_t = 0
Note: See TracChangeset for help on using the changeset viewer.