source: palm/trunk/SOURCE/local_stop.f90 @ 108

Last change on this file since 108 was 108, checked in by letzel, 17 years ago
  • Improved coupler: evaporation - salinity-flux coupling for humidity = .T.,

avoid MPI hangs when coupled runs terminate, add DOC/app/chapter_3.8;

  • Optional calculation of km and kh from initial TKE e_init;
  • Default initialization of km,kh = 0.00001 for ocean = .T.;
  • Allow data_output_pr= q, wq, w"q", w*q* for humidity = .T.;
  • Bugfix: Rayleigh damping for ocean fixed.
  • Property svn:keywords set to Id
File size: 3.3 KB
Line 
1 SUBROUTINE local_stop
2
3!------------------------------------------------------------------------------!
4! Actual revisions:
5! -----------------
6! modifications to terminate coupled runs
7!
8!
9! Former revisions:
10! -----------------
11! $Id: local_stop.f90 108 2007-08-24 15:10:38Z letzel $
12! RCS Log replace by Id keyword, revision history cleaned up
13!
14! Revision 1.2  2003/03/16 09:40:28  raasch
15! Two underscores (_) are placed in front of all define-strings
16!
17! Revision 1.1  2002/12/19 15:46:23  raasch
18! Initial revision
19!
20!
21! Description:
22! ------------
23! Stop program execution
24!------------------------------------------------------------------------------!
25
26    USE pegrid
27    USE control_parameters
28
29#if defined( __parallel )
30    IF ( coupling_mode == 'uncoupled' )  THEN
31       CALL MPI_FINALIZE( ierr )
32    ELSE
33
34       SELECT CASE ( terminate_coupled_remote )
35
36          CASE ( 0 )
37             IF ( myid == 0 )  THEN
38                PRINT*, '+++ local_stop:'
39                PRINT*, '    local model "', TRIM( coupling_mode ), &
40                     '" stops now'
41             ENDIF
42!
43!--          Inform the remote model of the termination and its reason, provided
44!--          the remote model has not already been informed of another
45!--          termination reason (terminate_coupled > 0) before.
46             IF ( terminate_coupled == 0 )  THEN
47                terminate_coupled = 1
48                CALL MPI_SENDRECV( &
49                     terminate_coupled,        1, MPI_INTEGER, myid,  0, &
50                     terminate_coupled_remote, 1, MPI_INTEGER, myid,  0, &
51                     comm_inter, status, ierr )
52             ENDIF
53             CALL MPI_FINALIZE( ierr )
54
55          CASE ( 1 )
56             IF ( myid == 0 )  THEN
57                PRINT*, '+++ local_stop:'
58                PRINT*, '    remote model "', TRIM( coupling_mode_remote ), &
59                     '" stopped'
60             ENDIF
61             CALL MPI_FINALIZE( ierr )
62
63          CASE ( 2 )
64             IF ( myid == 0 )  THEN
65                PRINT*, '+++ local_stop:'
66                PRINT*, '    remote model "', TRIM( coupling_mode_remote ), &
67                     '" terminated'
68                PRINT*, '    with stop_dt = .T.'
69             ENDIF
70             stop_dt = .TRUE.
71
72          CASE ( 3 )
73             IF ( myid == 0 )  THEN
74                PRINT*, '+++ local_stop:'
75                PRINT*, '    remote model "', TRIM( coupling_mode_remote ), &
76                     '" terminated'
77                PRINT*, '    with terminate_run = .T. (CPU-time limit)'
78             ENDIF
79             terminate_run = .TRUE.
80
81          CASE ( 4 )
82             IF ( myid == 0 )  THEN
83                PRINT*, '+++ local_stop:'
84                PRINT*, '    remote model "', TRIM( coupling_mode_remote ), &
85                     '" terminated'
86                PRINT*, '    with terminate_run = .T. (restart)'
87             ENDIF
88             terminate_run = .TRUE.
89             time_restart = time_restart + dt_restart
90
91          CASE ( 5 )
92             IF ( myid == 0 )  THEN
93                PRINT*, '+++ local_stop:'
94                PRINT*, '    remote model "', TRIM( coupling_mode_remote ), &
95                     '" terminated'
96                PRINT*, '    with terminate_run = .T. (single restart)'
97             ENDIF
98             terminate_run = .TRUE.
99             time_restart = 9999999.9
100
101       END SELECT
102
103    ENDIF
104
105#else
106
107    STOP
108
109#endif
110
111 END SUBROUTINE local_stop   
Note: See TracBrowser for help on using the repository browser.