  • doc/app/userint/output

    v47 v48  
    1313This example shows the output of the quantity "turbulent resolved-scale horizontal momentum flux" (''u*v*''). If more than one user-defined quantity shall be output, the following steps have to be carried out in the same way for each of the quantities.\\
    1414   1. The quantity has to be given a unique string identifier, e.g.'' 'u*v*'.'' This identifier must be different from the identifiers used for the {{{PALM}}} standard output (see list in description of parameter [../../d3par#data_output_pr data_output_pr]). To switch on output of this quantity, the user has to assign the string identifier to the parameter [../../userpar#data_output_pr_user data_output_pr_user], eg.:\\
    15 
    16    {{{data_output_pr_user = 'u*v*'}}}, \\
    17 
     15{{{
     16   data_output_pr_user = 'u*v*'}}}, \\
     17}}}
    1818   2. For the quantity, an identification number, a physical unit, and the vertical grid on which it is defined (u- or w-grid), has to be assigned (subroutine [../int#user_check_data_output_pr user_check]\\ [../int#user_check_data_output_pr _data_output_pr]): \\\\
    1919   {{{CASE ( 'u*v*' )}}} \\