40 | | [=#land_category '''land_category'''] |
41 | | }}} |
42 | | {{{#!td style="vertical-align:top; width: 50px" |
43 | | I |
44 | | }}} |
45 | | {{{#!td style="vertical-align:top; width: 75px" |
46 | | 2 |
47 | | }}} |
48 | | {{{#!td |
49 | | Land surface category.\\\\ |
50 | | Default category for land surface. '''Please note, this parameter is deprecated and will be removed soon.''' |
51 | | }}} |
52 | | |---------------- |
53 | | {{{#!td style="vertical-align:top; width: 150px" |
54 | | [=#naheatlayers '''naheatlayers'''] |
55 | | }}} |
56 | | {{{#!td style="vertical-align:top; width: 50px" |
57 | | I |
58 | | }}} |
59 | | {{{#!td style="vertical-align:top; width: 75px" |
60 | | 1 |
61 | | }}} |
62 | | {{{#!td |
63 | | Number of anthropogenic heat layers.\\\\ |
64 | | Number of layers where the anthropogenic heat is added into model. |
65 | | }}} |
66 | | |---------------- |
67 | | {{{#!td style="vertical-align:top; width: 150px" |
68 | | [=#pedestrian_category '''pedestrian_category'''] |
69 | | }}} |
70 | | {{{#!td style="vertical-align:top; width: 50px" |
71 | | I |
72 | | }}} |
73 | | {{{#!td style="vertical-align:top; width: 75px" |
74 | | 2 |
75 | | }}} |
76 | | {{{#!td |
77 | | Pedestrian wall category.\\\\ |
78 | | Default category for wall surface in pedestrian zone. |
79 | | }}} |
80 | | |---------------- |
81 | | {{{#!td style="vertical-align:top; width: 150px" |
82 | | [=#read_wall_temp_3d '''read_wall_temp_3d'''] |
83 | | }}} |
84 | | {{{#!td style="vertical-align:top; width: 50px" |
85 | | L |
86 | | }}} |
87 | | {{{#!td style="vertical-align:top; width: 75px" |
88 | | .F. |
89 | | }}} |
90 | | {{{#!td |
91 | | Read wall temperature initialization file.\\\\ |
92 | | Initialize temperature of wall layers and surfaces from supplied file instead of using default profiles. |
93 | | }}} |
94 | | |---------------- |
95 | | {{{#!td style="vertical-align:top; width: 150px" |
149 | | }}} |
150 | | |---------------- |
151 | | {{{#!td style="vertical-align:top; width: 150px" |
152 | | [=#usm_anthropogenic_heat '''usm_anthropogenic_heat'''] |
153 | | }}} |
154 | | {{{#!td style="vertical-align:top; width: 50px" |
155 | | L |
156 | | }}} |
157 | | {{{#!td style="vertical-align:top; width: 75px" |
158 | | .F. |
159 | | }}} |
160 | | {{{#!td |
161 | | Anthropogenic heat.\\\\ |
162 | | Enable supplied anthropogenic heat in USM model. |
163 | | '''Please note, anthropogenic heat parametrization considered in the USM is deprecated and requires a further ASCII input file. Instead, please enable the [../indoor_parameters indoor model]. |
164 | | }}} |
165 | | |---------------- |
166 | | {{{#!td style="vertical-align:top; width: 150px" |
167 | | [=#usm_material_model '''usm_material_model'''] |
168 | | }}} |
169 | | {{{#!td style="vertical-align:top; width: 50px" |
170 | | L |
171 | | }}} |
172 | | {{{#!td style="vertical-align:top; width: 75px" |
173 | | .T. |
174 | | }}} |
175 | | {{{#!td |
176 | | Material heat model.\\\\ |
177 | | Switch on calculation of propagation of heat in bare, green and window wall/ roof tiles. |