Changes between Version 23 and Version 24 of doc/app/particle_parameters


Ignore:
Timestamp:
Sep 13, 2010 11:24:29 AM (14 years ago)
Author:
suehring
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • doc/app/particle_parameters

    v23 v24  
    4242By default, particles are reflected at the bottom boundary. Alternatively, a particle absorption can set by '''bc_par_b''' = '' 'absorb' ''.
    4343}}}
     44|----------------
     45{{{#!td style="vertical-align:top"
     46[=#bc_par_lr '''bc_par_b''']
     47}}}
     48{{{#!td style="vertical-align:top"
     49C*15
     50}}}
     51{{{#!td style="vertical-align:top"
     52cyclic
     53}}}
     54{{{#!td
     55Lateral boundary condition (x-direction) for particle transport. \\
     56By default, cyclic boundary conditions are used along x. Alternatively, reflection ('''bc_par_lr''' = '' 'reflectï' '') or absorption ('''bc_par_lr''' = '' 'absorb' '') can be set. \\
     57This lateral boundary conditions should correspond to the lateral boundary condition used for the flow (see [..inipar#bc_lr bc_lr]).
     58}}}
    4459Table row with nesting:\\
    4560{{{#!td style="vertical-align:top"