  • doc/app/iofiles/pids/static

    v79 v80  
    131131||[=#obstruction_uv ''obstruction_uv(azimuth_uv,zenith_uv,y,x)''] || NC_BYTE     ||{{{_FillValue=-127b}}}(*)\\{{{coordinates}}}\\{{{flag_meanings="no obstruction, obstruction"}}}\\{{{flag_values=0b, 1b}}}\\{{{grid_mapping}}}\\{{{long_name="obstruction"}}}\\{{{res_orig}}}\\{{{source}}}\\{{{units="1"}}}\\{{{valid_range=0b, 1b}}}  || Obstruction of the sky at a pixel location (y,x). This field is needed only if the [wiki:doc/app/biometeorology_parameters#UVExposureModel UV exposure model] is used. ||
    132132||[=#zt ''zt(y,x)'']                       || NC_FLOAT     ||{{{_FillValue=-9999.f}}}(*)\\{{{coordinates}}}\\{{{grid_mapping}}}\\{{{long_name="terrain height"}}}\\{{{res_orig}}}\\{{{source}}}\\{{{units="m"}}} || Terrain height in m relative to [#origin_z origin_z]. If not provided, the relative terrain height will be set to 0 m all over the model domain. Please note, ''zt'' must not contain any {{{_FillValues}}}. ||
     133||[=#shf ''shf(y,x)'']                       || NC_FLOAT     ||{{{_FillValue=-9999.f}}}(*)\\{{{coordinates}}}\\{{{grid_mapping}}}\\{{{long_name="surface sensible heat flux"}}}\\{{{res_orig}}}\\{{{source}}}\\{{{units="m"}}} || Time-constant surface sensible heat flux. Note that input of ''shf'' is only useful for default-type surfaces, i.e., for simulations without [wiki:doc/tec/lsm land surface model] and [wiki:doc/tec/usm urban surface model]. ||
     134||[=#qsws ''qsws(y,x)'']                       || NC_FLOAT     ||{{{_FillValue=-9999.f}}}(*)\\{{{coordinates}}}\\{{{grid_mapping}}}\\{{{long_name="surface latent heat flux"}}}\\{{{res_orig}}}\\{{{source}}}\\{{{units="m"}}} || Time-constant surface latent heat flux. Note that input of ''shf'' is only useful for default-type surfaces, i.e., for simulations without [wiki:doc/tec/lsm land surface model] and [wiki:doc/tec/usm urban surface model]. ||
    133135||[=#z0 ''z0(y,x)'']                       || NC_FLOAT     ||{{{_FillValue=-9999.f}}}(*)\\{{{coordinates}}}\\{{{grid_mapping}}}\\{{{long_name="roughness length for momentum"}}}\\{{{res_orig}}}\\{{{source}}}\\{{{units="m"}}} || Roughness length for momentum. Note that input of ''z0'' is only useful for default-type surfaces, i.e., for simulations without [wiki:doc/tec/lsm land surface model] and [wiki:doc/tec/usm urban surface model]. ||
    134136