Changes between Version 22 and Version 23 of doc/app/iofiles/pids/static/tables


Ignore:
Timestamp:
Feb 19, 2021 12:11:27 PM (4 years ago)
Author:
suehring
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • doc/app/iofiles/pids/static/tables

    v22 v23  
    1515
    1616== [#building_pars ''building_pars(nbuilding_pars,y,x)'']
     17
     18[[span(style=color: #FF0000, Please note, buildings_pars will undergo a major revision soon. )]]
     19
    1720||='''nbuilding_pars'''   =||='''Units''' =||='''Description''' =||
    1821||  0|| 1 || Wall fraction above the ground floor level ||
     
    2124||  3|| 1 || Green fraction on roof ||
    2225||  4|| m²/m² || Leaf area index of green fraction on roof ||
    23 ||  5|| m²/m² || Leaf area index of green fraction on wall ||
    24 ||  6|| J/m²/K || Heat capacity of wall layer 1 ||
    25 ||  7|| J/m²/K || Heat capacity of wall layer 2 ||
    26 ||  8|| J/m²/K || Heat capacity of wall layer 3 ||
    27 ||  9|| W/m/K || Thermal conductivity of wall layer 1 ||
    28 || 10|| W/m/K || Thermal conductivity of wall layer 2 ||
    29 || 11|| W/m/K || Thermal conductivity of wall layer 3 ||
     26||  5|| m²/m² || Leaf area index of green fraction on wall above the ground floor level ||
     27||  6|| J/m²/K || Heat capacity of wall layer 1 above the ground floor level ||
     28||  7|| J/m²/K || Heat capacity of wall layer 2 above the ground floor level ||
     29||  8|| J/m²/K || Heat capacity of wall layer 3 above the ground floor level ||
     30||  9|| W/m/K || Thermal conductivity of wall layer 1 above the ground floor level ||
     31|| 10|| W/m/K || Thermal conductivity of wall layer 2 above the ground floor level ||
     32|| 11|| W/m/K || Thermal conductivity of wall layer 3 above the ground floor level ||
    3033|| 12|| K || Indoor target summer temperature ||
    3134|| 13|| K || Indoor target winter temperature ||
    32 || 14|| 1 || Emissivity of wall fraction ||
    33 || 15|| 1 || Emissivity of green fraction ||
    34 || 16|| 1 || Emissivity of window fraction ||
    35 || 17|| 1 || Transmissivity of window fraction ||
    36 || 18|| m || Roughness length for momentum ||
    37 || 19|| m || Roughness length for heat ||
     35|| 14|| 1 || Emissivity of wall fraction above the ground floor level ||
     36|| 15|| 1 || Emissivity of green fraction above the ground floor level ||
     37|| 16|| 1 || Emissivity of window fraction above the ground floor level ||
     38|| 17|| 1 || Transmissivity of window fraction above the ground floor level ||
     39|| 18|| m || Roughness length for momentum above the ground floor level ||
     40|| 19|| m || Roughness length for heat above the ground floor level ||
    3841|| 20|| m || Ground floor height ||
    3942|| 21|| 1 || Ground floor wall fraction ||
     
    6164|| 43|| m || Wall thickness of layer 3 ||
    6265|| 44|| m || Wall thickness of layer 4 ||
    63 || 45|| W/m²/K || Surface conductivity ||
    64 || 46|| J/m²/K || Surface heat capacity ||
     66|| 45|| J/m²/K || Surface wall heat capacity ||
     67|| 46|| W/m²/K || Surface wall conductivity ||
    6568|| 47|| J/m²/K || Heat capacity of window surface ||
    6669|| 48|| J/m²/K || Heat capacity of green surface ||
     
    7275|| 54*|| m || Thickness of ground plate wall layer 3 ||
    7376|| 55*|| m || Thickness of ground plate wall layer 4 ||
    74 || 56*|| J/m²/K || Heat capacity of ground plate wall layers 1 and 2 ||
    75 || 57*|| J/m²/K || Heat capacity of ground plate wall layer 3 ||
    76 || 58*|| J/m²/K || Heat capacity of ground plate wall layer 4 ||
    77 || 59*|| W/m/K || Thermal conductivity of ground plate wall layers 1 and 2 ||
    78 || 60*|| W/m/K || Thermal conductivity of ground plate wall layer 3 ||
    79 || 61*|| W/m/K || Thermal conductivity of ground plate wall layer 4 ||
     77|| 56*|| J/m²/K || Heat capacity of ground plate wall layers 1 ||
     78|| 57*|| J/m²/K || Heat capacity of ground plate wall layer 2 ||
     79|| 58*|| J/m²/K || Heat capacity of ground plate wall layer 3 ||
     80|| 59*|| W/m/K || Thermal conductivity of ground plate wall layers 1 ||
     81|| 60*|| W/m/K || Thermal conductivity of ground plate wall layer 2 ||
     82|| 61*|| W/m/K || Thermal conductivity of ground plate wall layer 3 ||
    8083|| 62|| m || Thickness of first floor wall layer 1 ||
    8184|| 63|| m || Thickness of first floor wall layer 2 ||
     
    8790|| 69|| m || Thickness of first floor window layer 3 ||
    8891|| 70|| m || Thickness of first floor window layer 4 ||
    89 || 71|| J/m²/K || Heat capacity of first floor window layers 1 and 2 ||
    90 || 72|| J/m²/K || Heat capacity of first floor window layer 3 ||
    91 || 73|| J/m²/K || Heat capacity of first floor window layer 4 ||
    92 || 74|| W/m/K || Thermal conductivity of first floor window layers 1 and 2 ||
    93 || 75|| W/m/K || Thermal conductivity of first floor window layer 3 ||
    94 || 76|| W/m/K || Thermal conductivity of first floor window layer 4 ||
     92|| 71|| J/m²/K || Heat capacity of first floor window layers 1 ||
     93|| 72|| J/m²/K || Heat capacity of first floor window layer 2 ||
     94|| 73|| J/m²/K || Heat capacity of first floor window layer 3 ||
     95|| 74|| W/m/K || Thermal conductivity of first floor window layers 1 ||
     96|| 75|| W/m/K || Thermal conductivity of first floor window layer 2 ||
     97|| 76|| W/m/K || Thermal conductivity of first floor window layer 3 ||
    9598|| 77|| 1 || Albedo of first floor window ||
    9699|| 78|| 1 || Albedo of first floor green surface ||
     
    99102|| 81|| m || Thickness of standard floor window layer 3 ||
    100103|| 82|| m || Thickness of standard floor window layer 4 ||
    101 || 83|| J/m²/K || Heat capacity of standard floor wall layers 1 and 2 ||
    102 || 84|| J/m²/K || Heat capacity of standard floor wall layer 3 ||
    103 || 85|| J/m²/K || Heat capacity of standard floor wall layer 4 ||
    104 || 86|| W/m/K || Thermal conductivity of standard floor wall layers 1 and 2 ||
    105 || 87|| W/m/K || Thermal conductivity of standard floor wall layer 3 ||
    106 || 88|| W/m/K || Thermal conductivity of standard floor wall layer 4 ||
     104|| 83|| J/m²/K || Heat capacity of standard floor wall layers 1 ||
     105|| 84|| J/m²/K || Heat capacity of standard floor wall layer 2 ||
     106|| 85|| J/m²/K || Heat capacity of standard floor wall layer 3 ||
     107|| 86|| W/m/K || Thermal conductivity of standard floor wall layers 1 ||
     108|| 87|| W/m/K || Thermal conductivity of standard floor wall layer 2 ||
     109|| 88|| W/m/K || Thermal conductivity of standard floor wall layer 3 ||
    107110|| 89|| 1 || Wall fraction of roof ||
    108111|| 90|| m || Thickness of roof layer 1 ||
     
    110113|| 92|| m || Thickness of roof layer 3 ||
    111114|| 93|| m || Thickness of roof layer 4 ||
    112 || 94|| J/m²/K || Heat capacity of roof layers 1 and 2 ||
    113 || 95|| J/m²/K || Heat capacity of roof layer 3 ||
    114 || 96|| J/m²/K || Heat capacity of roof layer 4 ||
    115 || 97|| W/m/K || Thermal conductivity of roof layers 1 and 2 ||
    116 || 98|| W/m/K || Thermal conductivity of roof layer 3 ||
    117 || 99|| W/m/K || Thermal conductivity of roof layer 4 ||
     115|| 94|| J/m²/K || Heat capacity of roof layers 1 ||
     116|| 95|| J/m²/K || Heat capacity of roof layer 2 ||
     117|| 96|| J/m²/K || Heat capacity of roof layer 3 ||
     118|| 97|| W/m/K || Thermal conductivity of roof layers 1 ||
     119|| 98|| W/m/K || Thermal conductivity of roof layer 2 ||
     120|| 99|| W/m/K || Thermal conductivity of roof layer 3 ||
    118121|| 100|| 1 || Emissivity of roof ||
    119122|| 101|| 1 || Albedo of roof ||
     
    123126|| 105|| m || Thickness of roof window layer 3 ||
    124127|| 106|| m || Thickness of roof window layer 4 ||
    125 || 107|| J/m²/K || Heat capacity of window layers 1 and 2 ||
    126 || 108|| J/m²/K || Heat capacity of window layer 3 ||
    127 || 109|| J/m²/K || Heat capacity of window layer 4 ||
    128 || 110|| W/m/K || Thermal conductivity of window layers 1 and 2 ||
    129 || 111|| W/m/K || Thermal conductivity of window layer 3 ||
    130 || 112|| W/m/K || Thermal conductivity of window layer 4 ||
     128|| 107|| J/m²/K || Heat capacity of window layers 1 ||
     129|| 108|| J/m²/K || Heat capacity of window layer 2 ||
     130|| 109|| J/m²/K || Heat capacity of window layer 3 ||
     131|| 110|| W/m/K || Thermal conductivity of window layers 1 ||
     132|| 111|| W/m/K || Thermal conductivity of window layer 2 ||
     133|| 112|| W/m/K || Thermal conductivity of window layer 3 ||
    131134|| 113|| 1 || Emissivity of roof window ||
    132135|| 114|| 1 || Transmissivity of roof window ||
     
    152155|| 134|| 1 || Technology heating factor for anthropogenic heat losses ||
    153156|| 135|| 1 || Technology cooling factor for anthropogenic heat losses ||
     157|| 136|| J/m²/K || Heat capacity of wall layer 4 above the ground floor level ||
     158|| 137|| W/m/K || Thermal conductivity of wall layer 4 above the ground floor level ||
     159|| 138|| J/m²/K || Heat capacity of wall layer 4 at the ground floor level ||
     160|| 139|| W/m/K || Thermal conductivity of wall layer 4 at the ground floor level ||
     161|| 140*|| J/m²/K || Heat capacity of wall layer 4 at ground plate ||
     162|| 141*|| W/m/K || Thermal conductivity of wall layer 4 at ground plate ||
     163|| 142|| J/m²/K || Heat capacity of window layer 4 at the ground floor level ||
     164|| 143|| W/m/K || Thermal conductivity of window layer 4 at the ground floor level ||
     165|| 144|| J/m²/K || Heat capacity of window layer 4 above the ground floor level ||
     166|| 145|| W/m/K || Thermal conductivity of window layer 4 above the ground floor level ||
     167|| 146|| J/m²/K || Heat capacity of wall layer 4 at roof ||
     168|| 147|| W/m/K || Thermal conductivity of wall layer 4 at roof ||
     169|| 148|| J/m²/K || Heat capacity of window layer 4 at roof ||
     170|| 149|| W/m/K ||  Thermal conductivity of window layer 4 at roof ||
    154171(*) are not processed by PALM at the moment.
    155172