| 17 | ||='''nbuilding_pars''' =||='''Units''' =||='''Description''' =|| |
| 18 | || 0|| 1 || Wall fraction || |
| 19 | || 1|| 1 || Window fraction || |
| 20 | || 2|| 1 || Green fraction on wall || |
| 21 | || 3|| 1 || Green fraction on roof || |
| 22 | || 4|| m²/m² || Leaf area index of green fraction on roof || |
| 23 | || 5|| m²/m² || Leaf area index of green fraction on wall || |
| 24 | || 6|| J/m²/K || Heat capacity of wall layer 1 || |
| 25 | || 7|| J/m²/K || Heat capacity of wall layer 2 || |
| 26 | || 8|| J/m²/K || Heat capacity of wall layer 3 || |
| 27 | || 9|| W/m/K || Thermal conductivity of wall layer 1 || |
| 28 | || 10|| W/m/K || Thermal conductivity of wall layer 2 || |
| 29 | || 11|| W/m/K || Thermal conductivity of wall layer 3 || |
| 30 | || 12|| K || Indoor target summer temperature || |
| 31 | || 13|| K || Indoor target winter temperature || |
| 32 | || 14|| 1 || Emissivity of wall fraction || |
| 33 | || 15|| 1 || Emissivity of green fraction |||| |
| 34 | || 16|| 1 || Emissivity of window fraction || |
| 35 | || 17|| 1 || Transmissivity of window fraction || |
| 36 | || 18|| m || Roughness length for momentum || |
| 37 | || 19|| m || Roughness length for heat || |
| 38 | || 20|| m || Ground floor height || |
| 39 | || 21|| 1 || Ground floor wall fraction || |
| 40 | || 22|| 1 || Ground floor window fraction || |
| 43 | == [#building_surface_pars ''building_surface_pars(nbuilding_surface_pars,ns)''] |
| 44 | ||='''nbuilding_surface_pars''' =||='''Units''' =||='''Description''' =|| |
| 45 | || 0|| 1 || Wall fraction || |
| 46 | || 1|| 1 || Window fraction || |
| 47 | || 2|| 1 || Green fraction on wall || |
| 48 | || 3|| 1 || Green fraction on roof || |
| 49 | || 4|| m²/m² || Leaf area index of green fraction || |
| 50 | || 5|| J/m²/K || Heat capacity of wall layer 1 || |
| 51 | || 6|| J/m²/K || Heat capacity of wall layer 2 || |
| 52 | || 7|| J/m²/K || Heat capacity of wall layer 3 || |
| 53 | || 8|| W/m/K || Thermal conductivity of wall layer 1 || |
| 54 | || 9|| W/m/K || Thermal conductivity of wall layer 2 || |
| 55 | || 10|| W/m/K || Thermal conductivity of wall layer 3 || |
| 56 | || 11|| K || Indoor target summer temperature || |
| 57 | || 12|| K || Indoor target winter temperature || |
| 58 | || 13|| 1 || Emissivity of wall fraction || |
| 59 | || 14|| 1 || Emissivity of green fraction |||| |
| 60 | || 15|| 1 || Emissivity of window fraction || |
| 61 | || 16|| 1 || Transmissivity of window fraction || |
| 62 | || 17|| m || Roughness length for momentum || |
| 63 | || 18|| m || Roughness length for heat || |
| 64 | || 19|| 1 || Broadband albedo of wall fraction || |
| 65 | || 20|| 1 || Longwave albedo of wall fraction || |
| 66 | || 21|| 1 || Shortwave albedo of wall fraction || |
| 67 | || 22|| 1 || Broadband albedo of window fraction || |
| 68 | || 23|| 1 || Longwave albedo of window fraction || |
| 69 | || 24|| 1 || Shortwave albedo of window fraction || |
| 70 | || 25|| 1 || Broadband albedo of green fraction || |
| 71 | || 26|| 1 || Longwave albedo of green fraction || |
| 72 | || 27|| 1 || Shorwave albedo of green fraction || |