Changes between Version 98 and Version 99 of doc/app/initialization_parameters


Ignore:
Timestamp:
Sep 15, 2010 12:44:12 PM (14 years ago)
Author:
kanani
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • doc/app/initialization_parameters

    v98 v99  
    22192219}}}
    22202220{{{#!td
    2221 Prescribed kinematic sensible heat flux in K m/s at the five topography faces:
    2222 
    2223 wall_heatflux(0)    top face
    2224 wall_heatflux(1)    left face
    2225 wall_heatflux(2)    right face
    2226 wall_heatflux(3)    south face
    2227 wall_heatflux(4)    north face
    2228 
    2229 This parameter applies only in case of a non-flat topography. The parameter random_heatflux can be used to impose random perturbations on the internal two-dimensional surface heat flux field shf that is composed of surface_heatflux at the bottom surface and wall_heatflux(0) at the topography top face.
     2221Prescribed kinematic sensible heat flux in K m/s at the five topography faces:\\\\
     2222'''wall_heatflux'''(0)    top face\\
     2223'''wall_heatflux'''(1)    left face\\
     2224'''wall_heatflux'''(2)    right face\\
     2225'''wall_heatflux'''(3)    south face\\
     2226'''wall_heatflux'''(4)    north face\\\\
     2227This parameter applies only in case of a non-flat topography. The parameter [#random_heatflux random_heatflux] can be used to impose random perturbations on the internal two-dimensional surface heat flux field '''shf''' that is composed of [#surface_heatflux surface_heatflux] at the bottom surface and '''wall_heatflux'''(0) at the topography top face.
    22302228}}}
    22312229|----------------
     
    22402238}}}
    22412239{{{#!td
    2242         Prescribed kinematic humidity flux in m/s at the five topography faces:
    2243 
    2244 wall_humidityflux(0)    top face
    2245 wall_humidityflux(1)    left face
    2246 wall_humidityflux(2)    right face
    2247 wall_humidityflux(3)    south face
    2248 wall_humidityflux(4)    north face
    2249 
    2250 This parameter applies only in case of a non-flat topography and humidity = .T.
     2240Prescribed kinematic humidity flux in m/s at the five topography faces:\\\\
     2241'''wall_humidityflux'''(0)    top face\\
     2242'''wall_humidityflux'''(1)    left face\\
     2243'''wall_humidityflux'''(2)    right face\\
     2244'''wall_humidityflux'''(3)    south face\\
     2245'''wall_humidityflux'''(4)    north face\\\\
     2246This parameter applies only in case of a non-flat topography and [#humidity humidity] = ''.T.''.
    22512247}}}
    22522248|----------------
     
    22612257}}}
    22622258{{{#!td
    2263 Prescribed scalar flux in kg/(m2 s) at the five topography faces:
    2264 
    2265 wall_scalarflux(0)    top face
    2266 wall_scalarflux(1)    left face
    2267 wall_scalarflux(2)    right face
    2268 wall_scalarflux(3)    south face
    2269 wall_scalarflux(4)    north face
    2270 
    2271 This parameter applies only in case of a non-flat topography and passive_scalar = .T.
     2259Prescribed scalar flux in kg/(m^2^ s) at the five topography faces:\\\\
     2260'''wall_scalarflux'''(0)    top face\\
     2261'''wall_scalarflux'''(1)    left face\\
     2262'''wall_scalarflux'''(2)    right face\\
     2263'''wall_scalarflux'''(3)    south face\\
     2264'''wall_scalarflux'''(4)    north face\\\\
     2265This parameter applies only in case of a non-flat topography and [#passive_scalar passive_scalar] = ''.T.''.
    22722266}}}
    22732267|----------------