v471 v472 2387 2387 }}} 2388 2388 {{{#!td 2389 Instead of prescribing a [#surface_heatflux surface_heatflux] also a surface heating rate can be prescribed by setting '''pt_surface_heating_rate''' to a non-zero value. The surface temperature pt(k=0) will than increase linearly by the given heating rate (in K/h). Surface cooling can be achieved by assigning a negative value.\\ 2389 Linear surface temperature increase by '''pt_surface_heating_rate''' (in K/h).\\ 2390 2391 Instead of prescribing a [#surface_heatflux surface_heatflux] also a surface heating rate can be prescribed by setting '''pt_surface_heating_rate''' to a non-zero value. Surface cooling can be achieved by assigning a negative value.\\ 2390 2392 Set [#bc_pt_b bc_pt_b] = '' 'dirichlet' ''.\\ 2391 2393 The surface heating can be combined with [#pt_surface_initial_change pt_surface_initial_change].