doc/app/initialization_parameters
v442 v443 1957 1957 The initial (quasi-stationary) turbulence field must be generated by a precursor run and used by setting [#initializing_actions initializing_actions] = '' 'cyclic_fill'.''\\\\ 1958 1958 The distance of the recycling plane from the inflow boundary can be set with parameter [#recycling_width recycling_width]. The height above ground above which the turbulence signal is not used for recycling and the width of the layer within the magnitude of the turbulence signal is damped from 100% to 0% can be set with parameters [#inflow_damping_height inflow_damping_height] and [#inflow_damping_width inflow_damping_width].\\\\ 1959 For thermodynamic quantities it is also possible to recycle the absolute values instead of the turbulent fluctuations by setting [#recycling_method_for_thermodynamic_quantities recycling_method_for_thermodynamic_quantities] to 'absolute_value'.\\\\ 1959 1960 The detailed setup for a turbulent inflow is described in [../examples/turbinf here]. 1960 1961 }}}