    3131Parameter to choose the approximation of the model equations. Currently two approximations are available:\\\\
    3232'' 'boussinesq' ''\\
    33       The Boussinesq approximation assumes an incompressible fluid. The density is assumed to be spatially and temporally constant. Internally the density is set to 1 kg/m3. \\\\
     33      The Boussinesq approximation assumes an incompressible fluid. The density is is assumed to be spatially and temporally constant. The constant density is calculated in accordance with the values given for the parameters [#surface_pressure surface_pressure] and [#pt_surface pt_surface]. \\\\
    3434'' 'anelastic' '' \\
    3535      The anelastic approximation allows for a density decrease with height. The density is however still horizontally and temporally constant. The vertical profile of the density is computed based on the [#surfaces_pressure surfaces_pressure] and the vertical profile of the potential temperature. The anelastic approximation requires [#momentum_advec momentum_advec] = "ws-scheme". Furthermore, [#conserve_volume_flow conserve_volume_flow] = .TRUE. is not supported.\\\\