Changes between Version 332 and Version 333 of doc/app/initialization_parameters
- Timestamp:
- Jun 7, 2017 2:06:15 PM (8 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
doc/app/initialization_parameters
v332 v333 2809 2809 }}} 2810 2810 {{{#!td style="vertical-align:top" 2811 5* 0.02811 6 * 0.0 2812 2812 }}} 2813 2813 {{{#!td … … 2817 2817 '''wall_heatflux'''(2) right face\\ 2818 2818 '''wall_heatflux'''(3) south face\\ 2819 '''wall_heatflux'''(4) north face\\\\ 2819 '''wall_heatflux'''(4) north face\\ 2820 '''wall_heatflux'''(5) bottom face\\\\ 2820 2821 This parameter applies only in case of a non-flat topography. Prescribing wall_heatflux additionally requires setting of [#surface_heatflux surface_heatflux]. Furthermore, please note that wall_heatflux(0) only describes the kinematic flux at non-zero height. At zero-height (surface) the kinematic flux is given by [#surface_heatflux surface_heatflux] instead. \\\\ 2821 2822 The parameter [#random_heatflux random_heatflux] can be used to impose random perturbations on the internal two-dimensional surface heat flux field '''shf''' that is composed of [#surface_heatflux surface_heatflux] at the bottom surface and '''wall_heatflux'''(0) at the topography top face. … … 2837 2838 '''wall_humidityflux'''(2) right face\\ 2838 2839 '''wall_humidityflux'''(3) south face\\ 2839 '''wall_humidityflux'''(4) north face\\\\ 2840 '''wall_humidityflux'''(4) north face\\ 2841 '''wall_humidityflux'''(5) bottom face\\\\ 2840 2842 This parameter applies only in case of a non-flat topography and [#humidity humidity] = ''.T.''. 2841 2843 Prescribing wall_humidityflux additionally requires setting of [#surface_waterflux surface_waterflux]. Furthermore, please note that wall_humidityflux(0) only describes the kinematic flux at non-zero height. At zero-height (surface) the kinematic flux is given by [#surface_waterflux surface_waterflux] instead. … … 2857 2859 '''wall_scalarflux'''(2) right face\\ 2858 2860 '''wall_scalarflux'''(3) south face\\ 2859 '''wall_scalarflux'''(4) north face\\\\ 2861 '''wall_scalarflux'''(4) north face\\ 2862 '''wall_scalarflux'''(5) bottom face\\\\ 2860 2863 This parameter applies only in case of a non-flat topography and [#passive_scalar passive_scalar] = ''.T.''. 2861 2864 Prescribing wall_scalarflux additionally requires setting of [#surface_scalarflux surface_scalarflux]. Furthermore, please note that wall_scalarflux(0) only describes the kinematic flux at non-zero height. At zero-height (surface) the kinematic flux is given by [#surface_scalarflux surface_scalarflux] instead.