    v324 v325  
    26902690'' 'read_from_file' ''
    26912691  Flow around arbitrary topography.
    2692   This mode requires the input file [../iofiles#TOPOGRAPHY_DATA TOPOGRAPHY_DATA]. This file contains the arbitrary topography height information in m. These data must exactly match the horizontal grid.\\\\
     2692  This mode requires the input file [../iofiles#TOPOGRAPHY_DATA TOPOGRAPHY_DATA]. This file contains the arbitrary topography height information in m. These data must exactly match the horizontal grid.
     2693'' 'tunnel' ''
     2694  Flow within a tunnel of finite or infinite length oriented either in x- or in y-direction.
     2695  The height of the tunnel outer top wall can be specified by [#tunnel_height tunnel_height].
     2696  The tunnel length and width can be specified via [#tunnel_length tunnel_length] and either [#tunnel_width_x tunnel_width_x] or [#tunnel_width_y tunnel_width_y].
     2697  Furthermore, the depth of tunnel walls can be specified by [#tunnel_wall_depth tunnel_wall_depth]. \\\\
    26932698Alternatively, the user may add code to the user interface subroutine [#user_init_grid user_init_grid] to allow further topography modes. These require to explicitly set the [#topography_grid_convention topography_grid_convention] to either '' 'cell_edge' '' or '' 'cell_center' ''.\\\\
    26942699Non-flat '''topography''' modes may assign a kinematic sensible [#wall_heatflux wall_heatflux] and a kinematic [#wall_humidityflux wall_humidityflux] (requires [#humidity humidity] = .T.) or a [#wall_scalarflux wall_scalarflux] (requires [#passive_scalar passive_scalar] = .T.) at the five topography faces.\\\\