Changes between Version 309 and Version 310 of doc/app/initialization_parameters
- Timestamp:
- Mar 20, 2017 8:48:59 AM (8 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
doc/app/initialization_parameters
v309 v310 1292 1292 }}} 1293 1293 {{{#!td style="vertical-align:top" 1294 'cyclic' 1294 'cyclic' ('nested' for nest domains) 1295 1295 }}} 1296 1296 {{{#!td … … 1307 1307 1308 1308 Detailed information can be found in the documentation of the [../../tec/noncyclic non-cyclic lateral boundary conditions]. 1309 1310 In case of nesting, bc_lr has default value of 'nested' for all nest-domains. 1309 1311 }}} 1310 1312 |---------------- … … 1316 1318 }}} 1317 1319 {{{#!td style="vertical-align:top" 1318 'cyclic' 1320 'cyclic' ('nested' for nest domains) 1319 1321 }}} 1320 1322 {{{#!td … … 1326 1328 For scalars, a Neumann (zero gradient) condition is used. For the perturbation pressure, Neumann (zero gradient) conditions are assumed both at the inflow and at the outflow.\\\\ 1327 1329 For further details regarding non-cyclic lateral boundary conditions see [#bc_lr bc_lr]. 1330 1331 In case of nesting, bc_ns has default value of 'nested' for all nest-domains. 1328 1332 }}} 1329 1333 |----------------