    v303 v304  
    27052705'''wall_heatflux'''(3)    south face\\
    27062706'''wall_heatflux'''(4)    north face\\\\
    2707 This parameter applies only in case of a non-flat topography. The parameter [#random_heatflux random_heatflux] can be used to impose random perturbations on the internal two-dimensional surface heat flux field '''shf''' that is composed of [#surface_heatflux surface_heatflux] at the bottom surface and '''wall_heatflux'''(0) at the topography top face.
     2707This parameter applies only in case of a non-flat topography. Prescribing wall_heatflux additionally requires setting of [#surface_heatflux surface_heatflux]. Furthermore, please note that wall_heatflux(0) only describes the kinematic flux at non-zero height. At zero-height (surface) the kinematic flux is given by [#surface_heatflux surface_heatflux] instead. \\\\
     2708The parameter [#random_heatflux random_heatflux] can be used to impose random perturbations on the internal two-dimensional surface heat flux field '''shf''' that is composed of [#surface_heatflux surface_heatflux] at the bottom surface and '''wall_heatflux'''(0) at the topography top face.
    27082709}}}
    27092710|----------------
     
    27252726'''wall_humidityflux'''(4)    north face\\\\
    27262727This parameter applies only in case of a non-flat topography and [#humidity humidity] = ''.T.''.
     2728Prescribing wall_humidityflux additionally requires setting of [#surface_waterflux surface_waterflux]. Furthermore, please note that wall_humidityflux(0) only describes the kinematic flux at non-zero height. At zero-height (surface) the kinematic flux is given by [#surface_waterflux surface_waterflux] instead.
    27272729}}}
    27282730|----------------
     
    27442746'''wall_scalarflux'''(4)    north face\\\\
    27452747This parameter applies only in case of a non-flat topography and [#passive_scalar passive_scalar] = ''.T.''.
     2748Prescribing wall_scalarflux additionally requires setting of [#surface_scalarflux surface_scalarflux]. Furthermore, please note that wall_scalarflux(0) only describes the kinematic flux at non-zero height. At zero-height (surface) the kinematic flux is given by [#surface_scalarflux surface_scalarflux] instead.
    27462749}}}
    27472750