Changes between Version 265 and Version 266 of doc/app/initialization_parameters
- Timestamp:
- Dec 2, 2015 7:43:38 AM (9 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
doc/app/initialization_parameters
v265 v266 1245 1245 In case of these non-cyclic lateral boundaries, a Dirichlet condition is used at the inflow for all quantities (initial vertical profiles - see [#initializing_actions initializing_actions] - are fixed during the run) except e, to which a Neumann (zero gradient) condition is applied. At the outflow, a radiation condition is used for all velocity components and the calculation method of the required phase velocity is controlled by the parameter [#use_cmax use_cmax]. 1246 1246 For scalars, a Neumann condition is used. For the perturbation pressure, Neumann conditions are assumed both at the inflow and at the outflow.\\\\ 1247 In order to maintain a turbulent state of the flow, it may be neccessary to continuously impose perturbations on the horizontal velocity field in the vicinity of the inflow throughout the whole run. This can be switched on using [../d3par#create_disturbances create_disturbances]. The horizontal range to which these perturbations are applied is controlled by the parameters [#inflow_disturbance_begin inflow_disturbance_begin] and [#inflow_disturbance_end inflow_disturbance_end]. The vertical range and the perturbation amplitude are given by [../d3par#disturbance_level_b disturbance_level_b], [../d3par#disturbance_level_t disturbance_level_t], and [../d3par#disturbance_amplitude disturbance_amplitude]. The time interval at which perturbations are to be imposed is set by [../d3par#dt_disturb dt_disturb]. \\\\1247 In order to maintain a turbulent state of the flow, it may be neccessary to continuously impose perturbations on the horizontal velocity field in the vicinity of the inflow throughout the whole run. This can be switched on using [../d3par#create_disturbances create_disturbances]. The horizontal range to which these perturbations are applied is controlled by the parameters [#inflow_disturbance_begin inflow_disturbance_begin] and [#inflow_disturbance_end inflow_disturbance_end]. The vertical range and the perturbation amplitude are given by [../d3par#disturbance_level_b disturbance_level_b], [../d3par#disturbance_level_t disturbance_level_t], and [../d3par#disturbance_amplitude disturbance_amplitude]. The time interval at which perturbations are to be imposed is set by [../d3par#dt_disturb dt_disturb]. Note that these inflow perturbances are added '''in addition''' to the standard perturbances that are activated with [../d3par#create_disturbances create_disturbances].\\\\ 1248 1248 In case of non-cyclic horizontal boundaries [#call_psolver_at_all_substeps call_psolver_at_all_substeps] = ''.T.'' should be used.\\\\ 1249 1249 '''Note:'''\\