Changes between Version 176 and Version 177 of doc/app/initialization_parameters
- Timestamp:
- Aug 10, 2012 3:00:57 PM (12 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
doc/app/initialization_parameters
v176 v177 1497 1497 {{{#!td 1498 1498 Roughness length (in m).\\\\ 1499 The roughness length can be varied for scalars (see [#z0h_factor z0h_factor]). \\\\ 1499 1500 This parameter is effective only in case that a Prandtl layer is switched on (see [#prandtl_layer prandtl_layer]). 1500 1501 }}} … … 1728 1729 With '''wall_adjustment''' = ''.T.,'' the mixing length is limited to a maximum of 1.8 * z. This condition typically affects only the first grid points above the bottom boundary.\\\\ 1729 1730 In case of a non-flat topography the respective horizontal distance from vertical walls is used. 1731 }}} 1732 |---------------- 1733 {{{#!td style="vertical-align:top" 1734 [=#z0h_factor '''z0h_factor'''] 1735 }}} 1736 {{{#!td style="vertical-align:top" 1737 R 1738 }}} 1739 {{{#!td style="vertical-align:top" 1740 1.0 1741 }}} 1742 {{{#!td 1743 Factor for calculating a roughness length for scalars.\\\\ 1744 A separated roughness length for scalars (potential temperature, humidity/scalar) can be set with this parameter. The roughness length for scalars z0h is calculated as: \\ 1745 z0h = z0h_factor * [#roughness_length roughness_length]. \\ 1746 This parameter is effective only in case that a Prandtl layer is switched on (see [#prandtl_layer prandtl_layer]). 1730 1747 }}} 1731 1748