source: palm/trunk/TESTS/cases/urban_environment_restart/MONITORING

Revision Log Mode:


Legend:

Added
Modified
Copied or renamed
Diff Rev Age Author Log Message
(edit) @4782   4 years gronemeier switched from deprecated to default radiation method in test cases; …
(edit) @4780   4 years suehring Urban-surface model and indoor model: Default building parameters …
(edit) @4748   4 years pavelkrc Fix previous commit (missing updated test results)
(edit) @4741   4 years suehring radiation: Add option to force calculation of horizontal mean profiles …
(edit) @4739   4 years maronga updated test cases
(edit) @4733   4 years maronga bugfix in calculation of absorbed shortwave radiation by windows
(edit) @4708   4 years suehring Bugfix, correct mapping of RRTMG heating rates, as well as …
(edit) @4702   4 years maronga removed unused variable in indoor model and updated urban_environment …
(edit) @4698   4 years maronga bugfix in urban surface model (introduced in previous revision)
(edit) @4689   4 years maronga further updated output files for last code change
(edit) @4669   4 years pavelkrc Fix multiple issues with radiation call times
(edit) @4661   4 years pavelkrc Update test results for fixed r_a limit; Bugfix for RTM v4.0
(edit) @4531   5 years moh.hefny update test cases and bugfix in radiation module in non-parallel case
(edit) @4494   5 years raasch some test case results updated to match last commit
(edit) @4446   5 years raasch bugfix for r4443: cycle number zero added to all monitoring and output …
(edit) @4347   5 years suehring Check for realistically initial values of mixing ratio implemented. …
(edit) @4327   5 years Giersch Setting of advection flags for vertical fluxes of w revised, Bugfix: …
(edit) @4254   5 years maronga update test cases for last commit
(edit) @4238   5 years suehring Building data base: Indoor-model parameters for some building types …
(edit) @4186   5 years suehring Enable limitation of Obukhov length so that it does not become zero; …
(edit) @4118   5 years suehring Initialization of soil temperature and moisture via dynamic input file …
(edit) @4105   5 years suehring Bugfix concerning ACC directive for non-allocated array in …
(edit) @4102   5 years suehring Bugfix, set Neumann boundary conditions for the subgrid TKE at …
(edit) @4085   5 years knoop Changed precomputed fractions from basic constants to be variable based
(edit) @4077   5 years gronemeier Set roughness length z0 and z0h/q at ground-floor level to same value …
(edit) @3914   6 years suehring In order to obtain correct surface temperature during spinup set …
(edit) @3732   6 years suehring update test cases for the urban environment
(edit) @3540   6 years gronemeier update test cases
(edit) @3449   6 years suehring Branch resler -r 3439 re-integrated into current trunk: RTM 3.0, …
(add) @3417   6 years kanani add new test cases for palmtest
Note: See TracRevisionLog for help on using the revision log.