Changeset 3479 for palm/trunk/SOURCE
- Timestamp:
- Nov 1, 2018 4:00:30 PM (6 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
palm/trunk/SOURCE/biometeorology_mod.f90
r3475 r3479 27 27 ! ----------------- 28 28 ! $Id$ 29 ! - reworked check for output quantities 30 ! - assign new palm-error numbers 31 ! - set unit according to data standard. 32 ! 33 ! 3475 2018-10-30 21:16:31Z kanani 29 34 ! Add option for using MRT from RTM instead of simplified global value 30 35 ! … … 482 487 SUBROUTINE biom_check_data_output( var, unit ) 483 488 484 USE control_parameters, & 485 ONLY: data_output, message_string 486 487 IMPLICIT NONE 488 489 CHARACTER (LEN=*) :: unit !< The unit for the variable var 490 CHARACTER (LEN=*) :: var !< The variable in question 491 492 493 unit = '°C' 494 IF ( .NOT. biometeorology ) THEN 495 message_string = 'output of "' // TRIM( var ) // '" req' // & 496 'uires biometeorology = .TRUE. in initialisati' & 497 // 'on_parameters' 498 CALL message( 'check_parameters', 'PA0114', 1, 2, 0, 6, 0 ) 499 unit = 'illegal' 500 ENDIF 501 IF ( .NOT. radiation ) THEN 502 message_string = 'output of "' // TRIM( var ) // '" require'& 503 // 's radiation = .TRUE.' 504 CALL message( 'check_parameters', 'PA0509', 1, 2, 0, 6, 0 ) 505 unit = 'illegal' 506 ENDIF 507 IF ( mrt_nlevels == 0 ) THEN 508 message_string = 'output of "' // TRIM( var ) // '" require'& 509 // 's mrt_nlevels > 0' 510 CALL message( 'check_parameters', 'PA0510', 1, 2, 0, 6, 0 ) 511 unit = 'illegal' 512 ENDIF 489 USE control_parameters, & 490 ONLY: data_output, message_string 491 492 IMPLICIT NONE 493 494 CHARACTER (LEN=*) :: unit !< The unit for the variable var 495 CHARACTER (LEN=*) :: var !< The variable in question 496 497 498 SELECT CASE ( TRIM( var ) ) 499 500 CASE( 'biom_tmrt', 'biom_mrt', 'biom_pet', 'biom_pt', 'biom_utci' ) 501 unit = 'degree_C' 502 503 CASE DEFAULT 504 unit = 'illegal' 505 506 END SELECT 507 508 IF ( unit /= 'illegal' ) THEN 509 ! 510 !-- Futher checks if output belongs to biometeorology 511 IF ( .NOT. biometeorology .OR. .NOT. radiation ) THEN 512 message_string = 'output of "' // TRIM( var ) // '" req' // & 513 'uires biometeorology = .TRUE. and radiation = .TRUE. ' & 514 // 'in initialisation_parameters' 515 CALL message( 'biom_check_data_output', 'PA0561', 1, 2, 0, 6, 0 ) 516 ENDIF 517 IF ( mrt_nlevels == 0 ) THEN 518 message_string = 'output of "' // TRIM( var ) // '" require'& 519 // 's mrt_nlevels > 0' 520 CALL message( 'biom_check_data_output', 'PA0562', 1, 2, 0, 6, 0 ) 521 ENDIF 522 523 ENDIF 513 524 514 525 END SUBROUTINE biom_check_data_output
Note: See TracChangeset
for help on using the changeset viewer.