Changeset 3151 for palm/trunk/SOURCE
- Timestamp:
- Jul 19, 2018 8:45:38 AM (6 years ago)
- Location:
- palm/trunk/SOURCE
- Files:
-
- 2 edited
Legend:
- Unmodified
- Added
- Removed
-
palm/trunk/SOURCE/sum_up_3d_data.f90
r3004 r3151 25 25 ! ----------------- 26 26 ! $Id$ 27 ! Remaining preprocessor directive __chem removed 28 ! 29 ! 3004 2018-04-27 12:33:25Z Giersch 27 30 ! prr field added to ONLY-list, prr* case/pr* case/precipitation_rate_av 28 31 ! removed, further allocation checks implemented … … 532 535 ! 533 536 !-- Chemical quantity 534 #if defined( __chem )535 537 IF ( air_chemistry .AND. trimvar(1:3) == 'kc_') THEN 536 538 CALL chem_3d_data_averaging( 'allocate', doav(ii) ) 537 539 ENDIF 538 #endif539 540 540 541 ! -
palm/trunk/SOURCE/urban_surface_mod.f90
r3136 r3151 28 28 ! ----------------- 29 29 ! $Id$ 30 ! remaining preprocessor define strings __check removed 31 ! 32 ! 3136 2018-07-16 14:48:21Z suehring 30 33 ! Limit also roughness length for heat and moisture where necessary 31 34 ! … … 372 375 373 376 !-- configuration parameters (they can be setup in PALM config) 374 LOGICAL 375 LOGICAL 376 LOGICAL 377 LOGICAL :: indoor_model = .FALSE.!< whether to use the indoor model378 LOGICAL 379 380 381 INTEGER(iwp) :: building_type = 1!< default building type (preleminary setting)382 INTEGER(iwp) :: land_category = 2!< default category for land surface383 INTEGER(iwp) :: wall_category = 2!< default category for wall surface over pedestrian zone384 INTEGER(iwp) :: pedestrian_category = 2!< default category for wall surface in pedestrian zone385 INTEGER(iwp) :: roof_category = 2!< default category for root surface386 REAL(wp) :: roughness_concrete = 0.001_wp!< roughness length of average concrete surface377 LOGICAL :: usm_material_model = .TRUE. !< flag parameter indicating wheather the model of heat in materials is used 378 LOGICAL :: usm_anthropogenic_heat = .FALSE. !< flag parameter indicating wheather the anthropogenic heat sources (e.g.transportation) are used 379 LOGICAL :: force_radiation_call_l = .FALSE. !< flag parameter for unscheduled radiation model calls 380 LOGICAL :: indoor_model = .FALSE. !< whether to use the indoor model 381 LOGICAL :: read_wall_temp_3d = .FALSE. 382 383 384 INTEGER(iwp) :: building_type = 1 !< default building type (preleminary setting) 385 INTEGER(iwp) :: land_category = 2 !< default category for land surface 386 INTEGER(iwp) :: wall_category = 2 !< default category for wall surface over pedestrian zone 387 INTEGER(iwp) :: pedestrian_category = 2 !< default category for wall surface in pedestrian zone 388 INTEGER(iwp) :: roof_category = 2 !< default category for root surface 389 REAL(wp) :: roughness_concrete = 0.001_wp !< roughness length of average concrete surface 387 390 ! 388 391 !-- Indices of input attributes for (above) ground floor level … … 5462 5465 ENDIF 5463 5466 5464 #if defined( __parallel ) && ! defined ( __check )5467 #if defined( __parallel ) 5465 5468 CALL MPI_BARRIER( comm2d, ierr ) 5466 5469 #endif … … 5496 5499 ENDIF 5497 5500 5498 #if defined( __parallel ) && ! defined ( __check )5501 #if defined( __parallel ) 5499 5502 CALL MPI_BARRIER( comm2d, ierr ) 5500 5503 #endif … … 6816 6819 6817 6820 ENDIF 6818 #if defined( __parallel ) && ! defined ( __check )6821 #if defined( __parallel ) 6819 6822 CALL MPI_BARRIER( comm2d, ierr ) 6820 6823 #endif 6821 6824 ENDDO 6822 6825 6823 6826 ! 6824 6827 !-- check completeness and formal correctness of the data 6825 6828 DO i = nxlg, nxrg … … 7253 7256 CALL message( 'usm_read_wall_temperature', 'PA0523', 1, 2, 0, 6, 0 ) 7254 7257 ENDIF 7255 #if defined( __parallel ) && ! defined ( __check )7258 #if defined( __parallel ) 7256 7259 CALL MPI_BARRIER( comm2d, ierr ) 7257 7260 #endif
Note: See TracChangeset
for help on using the changeset viewer.