Changeset 2042
- Timestamp:
- Nov 2, 2016 1:47:31 PM (8 years ago)
- Location:
- palm/trunk/SOURCE
- Files:
-
- 3 edited
Legend:
- Unmodified
- Added
- Removed
-
palm/trunk/SOURCE/check_parameters.f90
r2041 r2042 20 20 ! Current revisions: 21 21 ! ----------------- 22 ! 22 ! Additional checks for wall_heatflux, wall_humidityflux and wall_scalarflux. 23 ! Bugfix, check for constant_scalarflux. 23 24 ! 24 25 ! Former revisions: … … 1735 1736 ENDIF 1736 1737 1738 IF ( ANY( wall_heatflux /= 0.0_wp ) .AND. & 1739 surface_heatflux == 9999999.9_wp ) THEN 1740 message_string = 'wall_heatflux additionally requires ' // & 1741 'setting of surface_heatflux' 1742 CALL message( 'check_parameters', 'PA0443', 1, 2, 0, 6, 0 ) 1743 ENDIF 1744 1737 1745 ! 1738 1746 ! This IF clause needs revision, got too complex!! … … 1854 1862 !-- Set boundary conditions for total water content 1855 1863 IF ( humidity ) THEN 1864 1865 IF ( ANY( wall_humidityflux /= 0.0_wp ) .AND. & 1866 surface_waterflux == 9999999.9_wp ) THEN 1867 message_string = 'wall_humidityflux additionally requires ' // & 1868 'setting of surface_waterflux' 1869 CALL message( 'check_parameters', 'PA0444', 1, 2, 0, 6, 0 ) 1870 ENDIF 1871 1856 1872 CALL set_bc_scalars( 'q', bc_q_b, bc_q_t, ibc_q_b, ibc_q_t, & 1857 1873 'PA0071', 'PA0072' ) … … 1883 1899 1884 1900 IF ( passive_scalar ) THEN 1901 1902 IF ( ANY( wall_scalarflux /= 0.0_wp ) .AND. & 1903 surface_scalarflux == 9999999.9_wp ) THEN 1904 message_string = 'wall_scalarflux additionally requires ' // & 1905 'setting of surface_scalarflux' 1906 CALL message( 'check_parameters', 'PA0445', 1, 2, 0, 6, 0 ) 1907 ENDIF 1908 1909 IF ( surface_scalarflux == 9999999.9_wp ) constant_scalarflux = .FALSE. 1910 1885 1911 CALL set_bc_scalars( 's', bc_s_b, bc_s_t, ibc_s_b, ibc_s_t, & 1886 1912 'PA0071', 'PA0072' ) -
palm/trunk/SOURCE/read_var_list.f90
r2001 r2042 20 20 ! Current revisions: 21 21 ! ------------------ 22 ! 22 ! Bugfix, read restart data for wall_heatflux, wall_qflux and wall_sflux 23 23 ! 24 24 ! Former revisions: … … 764 764 CASE ( 'subs_vertical_gradient_level_i' ) 765 765 READ ( 13 ) subs_vertical_gradient_level_i 766 CASE ( 'wall_heatflux' ) 767 READ ( 13 ) wall_heatflux 768 CASE ( 'wall_qflux' ) 769 READ ( 13 ) wall_qflux 770 CASE ( 'wall_sflux' ) 771 READ ( 13 ) wall_sflux 766 772 CASE ( 'w_max' ) 767 773 READ ( 13 ) w_max -
palm/trunk/SOURCE/write_var_list.f90
r2001 r2042 20 20 ! Current revisions: 21 21 ! ----------------- 22 ! 22 ! Bugfix, write restart data for wall_heatflux, wall_qflux and wall_sflux 23 23 ! 24 24 ! Former revisions: … … 675 675 WRITE ( 14 ) 'subs_vertical_gradient_level_i' 676 676 WRITE ( 14 ) subs_vertical_gradient_level_i 677 WRITE ( 14 ) 'wall_heatflux ' 678 WRITE ( 14 ) wall_heatflux 679 WRITE ( 14 ) 'wall_qflux ' 680 WRITE ( 14 ) wall_qflux 681 WRITE ( 14 ) 'wall_sflux ' 682 WRITE ( 14 ) wall_sflux 677 683 WRITE ( 14 ) 'w_max ' 678 684 WRITE ( 14 ) w_max
Note: See TracChangeset
for help on using the changeset viewer.