Changeset 1806 for palm/trunk
- Timestamp:
- Apr 5, 2016 6:55:35 PM (9 years ago)
- Location:
- palm/trunk/SOURCE
- Files:
-
- 2 edited
Legend:
- Unmodified
- Added
- Removed
-
palm/trunk/SOURCE/check_parameters.f90
r1805 r1806 19 19 ! Current revisions: 20 20 ! ----------------- 21 ! 22 ! 21 ! Check for recycling_yshift 22 ! 23 23 ! Former revisions: 24 24 ! ----------------- … … 4148 4148 !-- Calculate the index 4149 4149 recycling_plane = recycling_width / dx 4150 ! 4151 !-- Because the y-shift is done with a distance of INT( npey / 2 ) no shift 4152 !-- is possible if there is only one PE in y direction. 4153 IF ( recycling_yshift .AND. pdims(2) < 2 ) THEN 4154 WRITE( message_string, * ) 'recycling_yshift = .T. requires more', & 4155 ' than one processor in y direction' 4156 CALL message( 'check_parameters', 'PA0421', 1, 2, 0, 6, 0 ) 4150 4157 ENDIF 4151 4158 -
palm/trunk/SOURCE/inflow_turbulence.f90
r1683 r1806 19 19 ! Current revisions: 20 20 ! ----------------- 21 ! 21 ! Added comments to variables and code segments. Removed code redundancies. 22 22 ! 23 23 ! Former revisions: … … 76 76 ONLY: cpu_log, log_point 77 77 78 USE grid_variables, &79 ONLY:80 81 78 USE indices, & 82 79 ONLY: nbgp, nxl, ny, nyn, nys, nyng, nysg, nzb, nzt … … 89 86 IMPLICIT NONE 90 87 91 INTEGER(iwp) :: i !< 92 INTEGER(iwp) :: j !< 93 INTEGER(iwp) :: k !< 94 INTEGER(iwp) :: l !< 95 INTEGER(iwp) :: next !< 96 INTEGER(iwp) :: ngp_ifd !< 97 INTEGER(iwp) :: ngp_pr !< 98 INTEGER(iwp) :: prev !< 88 INTEGER(iwp) :: i !< loop index 89 INTEGER(iwp) :: j !< loop index 90 INTEGER(iwp) :: k !< loop index 91 INTEGER(iwp) :: l !< loop index 92 INTEGER(iwp) :: next !< ID of receiving PE for y-shift 93 INTEGER(iwp) :: ngp_ifd !< number of grid points stored in avpr 94 INTEGER(iwp) :: ngp_pr !< number of grid points stored in inflow_dist 95 INTEGER(iwp) :: prev !< ID of sending PE for y-shift 99 96 100 97 REAL(wp), DIMENSION(nzb:nzt+1,6,nbgp) :: & 101 avpr, avpr_l !< 98 avpr !< stores averaged profiles at recycling plane 99 REAL(wp), DIMENSION(nzb:nzt+1,6,nbgp) :: & 100 avpr_l !< auxiliary variable to calculate avpr 102 101 REAL(wp), DIMENSION(nzb:nzt+1,nysg:nyng,6,nbgp) :: & 103 inflow_dist, local_inflow_dist !< 102 inflow_dist !< turbulence signal of vars, added at inflow boundary 103 REAL(wp), DIMENSION(nzb:nzt+1,nysg:nyng,6,nbgp) :: & 104 local_inflow_dist !< auxiliary variable for inflow_dist, used for yshift 104 105 105 106 CALL cpu_log( log_point(40), 'inflow_turbulence', 'start' ) … … 222 223 ENDIF 223 224 224 225 ! 226 !-- y-shift for inflow_dist 227 !-- Shift inflow_dist in positive y direction by a distance of INT( npey / 2 ) 225 228 IF ( recycling_yshift .AND. myidx == id_inflow ) THEN 226 227 IF ( pdims(2) >= 2 ) THEN 228 229 IF ( myidy >= INT( pdims(2) / 2 ) ) THEN 230 prev = myidy - INT( pdims(2) / 2 ) 231 ELSE 232 prev = pdims(2) - ( INT( pdims(2) / 2 ) - myidy ) 233 ENDIF 234 235 IF ( myidy < pdims(2) - INT( pdims(2) / 2 ) ) THEN 236 next = myidy + INT( pdims(2) / 2 ) 237 ELSE 238 next = INT( pdims(2) / 2 ) - ( pdims(2) - myidy ) 239 ENDIF 240 229 ! 230 !-- Calculate the ID of the PE which sends data to this PE (prev) and of the 231 !-- PE which receives data from this PE (next). 232 IF ( myidy >= INT( pdims(2) / 2 ) ) THEN 233 prev = myidy - INT( pdims(2) / 2 ) 234 ELSE 235 prev = pdims(2) - ( INT( pdims(2) / 2 ) - myidy ) 241 236 ENDIF 237 238 IF ( myidy < pdims(2) - INT( pdims(2) / 2 ) ) THEN 239 next = myidy + INT( pdims(2) / 2 ) 240 ELSE 241 next = INT( pdims(2) / 2 ) - ( pdims(2) - myidy ) 242 ENDIF 242 243 243 244 local_inflow_dist = 0.0_wp 244 245 245 246 CALL MPI_SENDRECV( inflow_dist(nzb,nysg,1,1), ngp_ifd, MPI_REAL, & 246 247 next, 1, local_inflow_dist(nzb,nysg,1,1), ngp_ifd, & 247 248 MPI_REAL, prev, 1, comm1dy, status, ierr ) 248 249 250 inflow_dist = local_inflow_dist 251 249 252 ENDIF 250 253 … … 254 257 !-- Add the disturbance at the inflow 255 258 IF ( nxl == 0 ) THEN 256 257 IF ( recycling_yshift ) THEN 258 259 DO j = nysg, nyng 260 DO k = nzb, nzt + 1 261 262 u(k,j,-nbgp+1:0) = mean_inflow_profiles(k,1) + & 263 local_inflow_dist(k,j,1,1:nbgp) * & 264 inflow_damping_factor(k) 265 v(k,j,-nbgp:-1) = mean_inflow_profiles(k,2) + & 266 local_inflow_dist(k,j,2,1:nbgp) * & 267 inflow_damping_factor(k) 268 w(k,j,-nbgp:-1) = & 269 local_inflow_dist(k,j,3,1:nbgp) * & 270 inflow_damping_factor(k) 271 pt(k,j,-nbgp:-1) = mean_inflow_profiles(k,4) + & 272 local_inflow_dist(k,j,4,1:nbgp) * & 273 inflow_damping_factor(k) 274 e(k,j,-nbgp:-1) = mean_inflow_profiles(k,5) + & 275 local_inflow_dist(k,j,5,1:nbgp) * & 276 inflow_damping_factor(k) 277 e(k,j,-nbgp:-1) = MAX( e(k,j,-nbgp:-1), 0.0_wp ) 278 279 IF ( humidity .OR. passive_scalar ) & 280 q(k,j,-nbgp:-1) = mean_inflow_profiles(k,6) + & 281 local_inflow_dist(k,j,6,1:nbgp) * & 282 inflow_damping_factor(k) 283 284 ENDDO 285 ENDDO 286 287 ELSE 288 289 DO j = nysg, nyng 290 DO k = nzb, nzt + 1 291 292 u(k,j,-nbgp+1:0) = mean_inflow_profiles(k,1) + & 293 inflow_dist(k,j,1,1:nbgp) * inflow_damping_factor(k) 294 v(k,j,-nbgp:-1) = mean_inflow_profiles(k,2) + & 295 inflow_dist(k,j,2,1:nbgp) * inflow_damping_factor(k) 296 w(k,j,-nbgp:-1) = & 297 inflow_dist(k,j,3,1:nbgp) * inflow_damping_factor(k) 298 pt(k,j,-nbgp:-1) = mean_inflow_profiles(k,4) + & 299 inflow_dist(k,j,4,1:nbgp) * inflow_damping_factor(k) 300 e(k,j,-nbgp:-1) = mean_inflow_profiles(k,5) + & 301 inflow_dist(k,j,5,1:nbgp) * inflow_damping_factor(k) 302 e(k,j,-nbgp:-1) = MAX( e(k,j,-nbgp:-1), 0.0_wp ) 303 304 IF ( humidity .OR. passive_scalar ) & 305 q(k,j,-nbgp:-1) = mean_inflow_profiles(k,6) + & 306 inflow_dist(k,j,6,1:nbgp) * inflow_damping_factor(k) 307 308 ENDDO 309 ENDDO 310 311 ENDIF 312 259 260 DO j = nysg, nyng 261 DO k = nzb, nzt + 1 262 263 u(k,j,-nbgp+1:0) = mean_inflow_profiles(k,1) + & 264 inflow_dist(k,j,1,1:nbgp) * inflow_damping_factor(k) 265 v(k,j,-nbgp:-1) = mean_inflow_profiles(k,2) + & 266 inflow_dist(k,j,2,1:nbgp) * inflow_damping_factor(k) 267 w(k,j,-nbgp:-1) = & 268 inflow_dist(k,j,3,1:nbgp) * inflow_damping_factor(k) 269 pt(k,j,-nbgp:-1) = mean_inflow_profiles(k,4) + & 270 inflow_dist(k,j,4,1:nbgp) * inflow_damping_factor(k) 271 e(k,j,-nbgp:-1) = mean_inflow_profiles(k,5) + & 272 inflow_dist(k,j,5,1:nbgp) * inflow_damping_factor(k) 273 e(k,j,-nbgp:-1) = MAX( e(k,j,-nbgp:-1), 0.0_wp ) 274 275 IF ( humidity .OR. passive_scalar ) & 276 q(k,j,-nbgp:-1) = mean_inflow_profiles(k,6) + & 277 inflow_dist(k,j,6,1:nbgp) * inflow_damping_factor(k) 278 279 ENDDO 280 ENDDO 281 313 282 ENDIF 314 283
Note: See TracChangeset
for help on using the changeset viewer.