[3471] | 1 | !> @virtual_measurement_mod.f90 |
---|
[3434] | 2 | !------------------------------------------------------------------------------! |
---|
| 3 | ! This file is part of the PALM model system. |
---|
| 4 | ! |
---|
| 5 | ! PALM is free software: you can redistribute it and/or modify it under the |
---|
| 6 | ! terms of the GNU General Public License as published by the Free Software |
---|
| 7 | ! Foundation, either version 3 of the License, or (at your option) any later |
---|
| 8 | ! version. |
---|
| 9 | ! |
---|
| 10 | ! PALM is distributed in the hope that it will be useful, but WITHOUT ANY |
---|
| 11 | ! WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR |
---|
| 12 | ! A PARTICULAR PURPOSE. See the GNU General Public License for more details. |
---|
| 13 | ! |
---|
| 14 | ! You should have received a copy of the GNU General Public License along with |
---|
| 15 | ! PALM. If not, see <http://www.gnu.org/licenses/>. |
---|
| 16 | ! |
---|
| 17 | ! Copyright 2017 Leibniz Universitaet Hannover |
---|
| 18 | !------------------------------------------------------------------------------! |
---|
| 19 | ! |
---|
| 20 | ! Current revisions: |
---|
| 21 | ! ----------------- |
---|
| 22 | ! |
---|
[3473] | 23 | ! |
---|
[3434] | 24 | ! Former revisions: |
---|
| 25 | ! ----------------- |
---|
[3472] | 26 | ! $Id: virtual_measurement_mod.f90 3494 2018-11-06 14:51:27Z suehring $ |
---|
[3494] | 27 | ! Bugfixing |
---|
| 28 | ! |
---|
| 29 | ! 3473 2018-10-30 20:50:15Z suehring |
---|
[3473] | 30 | ! Initial revision |
---|
| 31 | ! |
---|
| 32 | ! 3472 2018-10-30 20:43:50Z suehring |
---|
[3434] | 33 | ! |
---|
| 34 | ! Authors: |
---|
| 35 | ! -------- |
---|
[3494] | 36 | ! @author Matthias Suehring and Klaus Ketelsen |
---|
[3434] | 37 | ! |
---|
| 38 | ! |
---|
| 39 | ! |
---|
| 40 | ! Description: |
---|
| 41 | ! ------------ |
---|
[3471] | 42 | !> The module acts as an interface between 'real-world' observations and |
---|
| 43 | !> model simulations. Virtual measurements will be taken in the model at the |
---|
| 44 | !> coordinates representative for the 'real-world' measurement positions. |
---|
| 45 | !> More precisely, coordinates and measured quanties will be read from a |
---|
| 46 | !> NetCDF file which contains all required information. In the model, |
---|
| 47 | !> the same quantities (as long as all the required components are switched-on) |
---|
| 48 | !> will be sampled at the respective positions and output into an extra file, |
---|
| 49 | !> which allows for straight-forward comparison of model results with |
---|
| 50 | !> observations. |
---|
[3434] | 51 | !------------------------------------------------------------------------------! |
---|
[3471] | 52 | MODULE virtual_measurement_mod |
---|
[3434] | 53 | |
---|
| 54 | |
---|
| 55 | USE arrays_3d, & |
---|
| 56 | ONLY: q, pt, u, v, w, zu, zw |
---|
| 57 | |
---|
| 58 | USE control_parameters, & |
---|
| 59 | ONLY: dz, message_string, virtual_measurement |
---|
| 60 | |
---|
| 61 | USE cpulog, & |
---|
| 62 | ONLY: cpu_log, log_point |
---|
| 63 | |
---|
| 64 | USE grid_variables, & |
---|
| 65 | ONLY: dx, dy |
---|
| 66 | |
---|
| 67 | USE indices, & |
---|
| 68 | ONLY: nzb, nzt, nxl, nxr, nys, nyn |
---|
| 69 | |
---|
| 70 | USE kinds |
---|
| 71 | |
---|
| 72 | |
---|
| 73 | IMPLICIT NONE |
---|
| 74 | |
---|
| 75 | TYPE virt_mea |
---|
| 76 | |
---|
| 77 | CHARACTER(LEN=100) :: feature_type !< type of the measurement |
---|
| 78 | CHARACTER(LEN=100) :: site !< name of the measurement site |
---|
| 79 | |
---|
| 80 | CHARACTER(LEN=10), DIMENSION(:), ALLOCATABLE :: measured_vars_name !< name of the measured variables |
---|
| 81 | |
---|
| 82 | INTEGER(iwp) :: ns !< total number of observation points for a site on subdomain, i.e. sum of all trajectories |
---|
| 83 | INTEGER(iwp) :: ntraj !< number of trajectories of a measurement |
---|
| 84 | INTEGER(iwp) :: nvar !< number of measured variables |
---|
| 85 | |
---|
| 86 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: dim_t !< number observations individual for each trajectory or station that are no _FillValues |
---|
| 87 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: ngp !< number of grid points where observations for a site took place, |
---|
| 88 | !<individual for each trajectory or station that are no _FillValues |
---|
| 89 | |
---|
| 90 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: i !< grid index for measurement position in x-direction |
---|
| 91 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: j !< grid index for measurement position in y-direction |
---|
| 92 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: k !< grid index for measurement position in k-direction |
---|
| 93 | |
---|
| 94 | LOGICAL :: trajectory = .FALSE. !< flag indicating that the observation is a mobile observation |
---|
| 95 | LOGICAL :: timseries = .FALSE. !< flag indicating that the observation is a stationary point measurement |
---|
| 96 | LOGICAL :: timseries_profile = .FALSE. !< flag indicating that the observation is a stationary profile measurement |
---|
| 97 | |
---|
| 98 | REAL(wp) :: fill_eutm !< fill value for UTM coordinates in case of missing values |
---|
| 99 | REAL(wp) :: fill_nutm !< fill value for UTM coordinates in case of missing values |
---|
| 100 | REAL(wp) :: fill_zag !< fill value for heigth coordinates in case of missing values |
---|
| 101 | REAL(wp) :: fillout = -999.9 !< fill value for output in case a observation is taken from inside a building |
---|
| 102 | REAL(wp) :: origin_x_obs !< origin of the observation in UTM coordiates in x-direction |
---|
| 103 | REAL(wp) :: origin_y_obs !< origin of the observation in UTM coordiates in y-direction |
---|
| 104 | |
---|
| 105 | REAL(wp), DIMENSION(:,:), ALLOCATABLE :: xmea !< measurement x-position in absolute UTM coordinates |
---|
| 106 | REAL(wp), DIMENSION(:,:), ALLOCATABLE :: ymea !< measurement y-position in absolute UTM coordinates |
---|
| 107 | REAL(wp), DIMENSION(:,:), ALLOCATABLE :: zmea !< measurement z-position in height above ground level |
---|
| 108 | |
---|
| 109 | REAL(wp), DIMENSION(:,:), ALLOCATABLE :: measured_vars !< measured variables |
---|
| 110 | |
---|
| 111 | END TYPE virt_mea |
---|
| 112 | |
---|
| 113 | CHARACTER(LEN=5) :: char_eutm = "E_UTM" !< dimension name for UTM coordinate easting |
---|
| 114 | CHARACTER(LEN=11) :: char_feature = "featureType" !< attribute name for feature type |
---|
| 115 | CHARACTER(LEN=10) :: char_fillvalue = "_FillValue" !< variable attribute name for _FillValue |
---|
| 116 | CHARACTER(LEN=18) :: char_mv = "measured_variables" !< variable name for the array with the measured variable names |
---|
| 117 | CHARACTER(LEN=5) :: char_nutm = "N_UTM" !< dimension name for UTM coordinate northing |
---|
| 118 | CHARACTER(LEN=18) :: char_numstations = "number_of_stations" !< attribute name for number of stations |
---|
| 119 | CHARACTER(LEN=8) :: char_origx = "origin_x" !< attribute name for station coordinate in x |
---|
| 120 | CHARACTER(LEN=8) :: char_origy = "origin_y" !< attribute name for station coordinate in y |
---|
| 121 | CHARACTER(LEN=4) :: char_site = "site" !< attribute name for site name |
---|
| 122 | CHARACTER(LEN=19) :: char_zag = "height_above_ground" !< attribute name for height above ground variable |
---|
| 123 | CHARACTER(LEN=10) :: type_ts = 'timeSeries' !< name of stationary point measurements |
---|
| 124 | CHARACTER(LEN=10) :: type_traj = 'trajectory' !< name of line measurements |
---|
| 125 | CHARACTER(LEN=17) :: type_tspr = 'timeSeriesProfile' !< name of stationary profile measurements |
---|
| 126 | |
---|
[3471] | 127 | CHARACTER(LEN=10), DIMENSION(1:53), PARAMETER :: list_allowed_variables = & !< variables that can be sampled in PALM |
---|
| 128 | (/ 'hfls ', & ! surface latent heat flux (W/m2) |
---|
| 129 | 'hfss ', & ! surface sensible heat flux (W/m2) |
---|
| 130 | 'hur ', & ! relative humidity (-) |
---|
| 131 | 'hus ', & ! specific humidity (g/kg) |
---|
| 132 | 'haa ', & ! absolute atmospheric humidity (kg/m3) |
---|
| 133 | 'mcpm1 ', & ! mass concentration of PM1 (kg/m3) |
---|
| 134 | 'mcpm2p5 ', & ! mass concentration of PM2.5 (kg/m3) |
---|
| 135 | 'mcpm10 ', & ! mass concentration of PM10 (kg/m3) |
---|
| 136 | 'mcpm10 ', & ! mass concentration of PM10 (kg/m3) |
---|
| 137 | 'mcco ', & ! mass concentration of CO (kg/m3) |
---|
| 138 | 'mcco2 ', & ! mass concentration of CO2 (kg/m3) |
---|
| 139 | 'mcbcda ', & ! mass concentration of black carbon paritcles (kg/m3) |
---|
| 140 | 'ncaa ', & ! number concentation of particles (1/m3) |
---|
| 141 | 'mfco2 ', & ! mole fraction of CO (mol/mol) |
---|
| 142 | 'mfco2 ', & ! mole fraction of CO2 (mol/mol) |
---|
| 143 | 'mfch4 ', & ! mole fraction of methane (mol/mol) |
---|
| 144 | 'mfnh3 ', & ! mole fraction of amonia (mol/mol) |
---|
| 145 | 'mfno ', & ! mole fraction of nitrogen monoxide (mol/mol) |
---|
| 146 | 'mfno2 ', & ! mole fraction of nitrogen dioxide (mol/mol) |
---|
| 147 | 'mfso2 ', & ! mole fraction of sulfur dioxide (mol/mol) |
---|
| 148 | 'mfh20 ', & ! mole fraction of water (mol/mol) |
---|
| 149 | 'plev ', & ! ? air pressure - hydrostaic + perturbation? |
---|
| 150 | 'rlds ', & ! surface downward longwave flux (W/m2) |
---|
| 151 | 'rlus ', & ! surface upward longwave flux (W/m2) |
---|
| 152 | 'rsds ', & ! surface downward shortwave flux (W/m2) |
---|
| 153 | 'rsus ', & ! surface upward shortwave flux (W/m2) |
---|
| 154 | 'ta ', & ! air temperature (degree C) |
---|
| 155 | 't_va ', & ! virtual accoustic temperature (K) |
---|
| 156 | 'theta ', & ! potential temperature (K) |
---|
| 157 | 'tro3 ', & ! mole fraction of ozone air (mol/mol) |
---|
| 158 | 'ts ', & ! scaling parameter of temperature (K) |
---|
| 159 | 'wspeed ', & ! ? wind speed - horizontal? |
---|
| 160 | 'wdir ', & ! wind direction |
---|
| 161 | 'us ', & ! friction velocity |
---|
| 162 | 'msoil ', & ! ? soil moisture - which depth? |
---|
| 163 | 'tsoil ', & ! ? soil temperature - which depth? |
---|
| 164 | 'u ', & ! u-component |
---|
| 165 | 'ua ', & ! eastward wind (is there any difference to u?) |
---|
| 166 | 'uw ', & ! ? vertical momentum flux - total ? |
---|
| 167 | 'utheta ', & ! ? horizontal heat flux - total ? |
---|
| 168 | 'uv ', & ! upward-northward horizontal momentum flux |
---|
| 169 | 'v ', & ! v-component |
---|
| 170 | 'va ', & ! northward wind (is there any difference to v?) |
---|
| 171 | 'vw ', & ! ? vertical momentum flux - total ? |
---|
| 172 | 'vtheta ', & ! ? horizontal heat flux - total ? |
---|
| 173 | 'w ', & ! w-component |
---|
| 174 | 'wtheta ', & ! ? vertical heat flux - total ? |
---|
| 175 | 'rld ', & ! downward longwave radiative flux (W/m2) |
---|
| 176 | 'rlu ', & ! upnward longwave radiative flux (W/m2) |
---|
| 177 | 'rsd ', & ! downward shortwave radiative flux (W/m2) |
---|
| 178 | 'rsu ', & ! upward shortwave radiative flux (W/m2) |
---|
| 179 | 'rsddif ', & ! downward shortwave diffuse radiative flux (W/m2) |
---|
| 180 | 'rnds ' & ! surface net downward radiative flux (W/m2) |
---|
| 181 | /) |
---|
[3434] | 182 | |
---|
| 183 | INTEGER(iwp) :: id_vm !< NetCDF file id for virtual measurements |
---|
| 184 | INTEGER(iwp) :: nvm = 0 !< number of virtual measurements |
---|
| 185 | INTEGER(iwp) :: observation_coverage_xy = 0 !< horizontal distance from the measurement point where observations should be taken in the surrounding |
---|
| 186 | INTEGER(iwp) :: observation_coverage_z = 0 !< vertical distance from the measurement point where observations should be taken in the surrounding |
---|
| 187 | |
---|
| 188 | LOGICAL :: use_virtual_measurement = .FALSE. !< Namelist parameter |
---|
| 189 | LOGICAL :: global_attribute = .TRUE. !< flag indicating a global attribute |
---|
| 190 | |
---|
| 191 | REAL(wp) :: vm_time_start = 0.0 !< time after virtual measurements should start |
---|
| 192 | |
---|
| 193 | |
---|
| 194 | TYPE( virt_mea ), DIMENSION(:), ALLOCATABLE :: vmea !< virtual measurement data structure |
---|
| 195 | |
---|
| 196 | |
---|
| 197 | INTERFACE vm_check_parameters |
---|
| 198 | MODULE PROCEDURE vm_check_parameters |
---|
| 199 | END INTERFACE vm_check_parameters |
---|
| 200 | |
---|
| 201 | INTERFACE vm_init |
---|
| 202 | MODULE PROCEDURE vm_init |
---|
| 203 | END INTERFACE vm_init |
---|
| 204 | |
---|
| 205 | INTERFACE vm_parin |
---|
| 206 | MODULE PROCEDURE vm_parin |
---|
| 207 | END INTERFACE vm_parin |
---|
| 208 | |
---|
| 209 | INTERFACE vm_sampling |
---|
| 210 | MODULE PROCEDURE vm_sampling |
---|
| 211 | END INTERFACE vm_sampling |
---|
| 212 | |
---|
| 213 | SAVE |
---|
| 214 | |
---|
| 215 | PRIVATE |
---|
| 216 | |
---|
| 217 | ! |
---|
| 218 | !-- Public interfaces |
---|
| 219 | PUBLIC vm_check_parameters, vm_init, vm_parin, vm_sampling |
---|
| 220 | |
---|
| 221 | ! |
---|
| 222 | !-- Public variables |
---|
| 223 | PUBLIC vmea, vm_time_start |
---|
| 224 | |
---|
| 225 | CONTAINS |
---|
| 226 | |
---|
| 227 | |
---|
| 228 | !------------------------------------------------------------------------------! |
---|
| 229 | ! Description: |
---|
| 230 | ! ------------ |
---|
[3471] | 231 | !> Check parameters for virtual measurement module |
---|
[3434] | 232 | !------------------------------------------------------------------------------! |
---|
| 233 | SUBROUTINE vm_check_parameters |
---|
| 234 | |
---|
| 235 | USE control_parameters, & |
---|
| 236 | ONLY: message_string, virtual_measurement |
---|
| 237 | |
---|
| 238 | USE netcdf_data_input_mod, & |
---|
| 239 | ONLY: input_pids_static |
---|
| 240 | |
---|
| 241 | IMPLICIT NONE |
---|
| 242 | |
---|
| 243 | ! |
---|
| 244 | !-- In case virtual measurements are taken, a static input file is required. |
---|
| 245 | !-- This is because UTM coordinates for the PALM domain origin are required |
---|
| 246 | !-- for correct mapping of the measurements. |
---|
| 247 | !-- ToDo: Revise this later and remove this requirement. |
---|
| 248 | IF ( virtual_measurement .AND. .NOT. input_pids_static ) THEN |
---|
| 249 | message_string = 'If virtual measurements are taken a static input ' // & |
---|
| 250 | 'file is mandatory.' |
---|
| 251 | CALL message( 'vm_check_parameters', 'PA0000', 1, 2, 0, 6, 0 ) |
---|
| 252 | ENDIF |
---|
| 253 | |
---|
| 254 | END SUBROUTINE vm_check_parameters |
---|
| 255 | |
---|
| 256 | !------------------------------------------------------------------------------! |
---|
| 257 | ! Description: |
---|
| 258 | ! ------------ |
---|
[3471] | 259 | !> Read namelist for the virtual measurement module |
---|
[3434] | 260 | !------------------------------------------------------------------------------! |
---|
| 261 | SUBROUTINE vm_parin |
---|
| 262 | |
---|
| 263 | CHARACTER (LEN=80) :: line !< dummy string that contains the current line of the parameter file |
---|
| 264 | |
---|
| 265 | NAMELIST /virtual_measurement_parameters/ use_virtual_measurement, & |
---|
| 266 | vm_time_start |
---|
| 267 | |
---|
| 268 | line = ' ' |
---|
| 269 | |
---|
| 270 | ! |
---|
| 271 | !-- Try to find stg package |
---|
| 272 | REWIND ( 11 ) |
---|
| 273 | line = ' ' |
---|
| 274 | DO WHILE ( INDEX( line, '&virtual_measurement_parameters' ) == 0 ) |
---|
| 275 | READ ( 11, '(A)', END=20 ) line |
---|
| 276 | ENDDO |
---|
| 277 | BACKSPACE ( 11 ) |
---|
| 278 | |
---|
| 279 | ! |
---|
| 280 | !-- Read namelist |
---|
| 281 | READ ( 11, virtual_measurement_parameters, ERR = 10, END = 20 ) |
---|
| 282 | |
---|
| 283 | ! |
---|
[3471] | 284 | !-- Set flag that indicates that the virtual measurement module is switched on |
---|
[3434] | 285 | IF ( use_virtual_measurement ) virtual_measurement = .TRUE. |
---|
| 286 | |
---|
| 287 | GOTO 20 |
---|
| 288 | |
---|
| 289 | 10 BACKSPACE( 11 ) |
---|
| 290 | READ( 11 , '(A)') line |
---|
| 291 | CALL parin_fail_message( 'virtual_measurement_parameters', line ) |
---|
| 292 | |
---|
| 293 | 20 CONTINUE |
---|
| 294 | |
---|
| 295 | END SUBROUTINE vm_parin |
---|
| 296 | |
---|
| 297 | |
---|
| 298 | !------------------------------------------------------------------------------! |
---|
| 299 | ! Description: |
---|
| 300 | ! ------------ |
---|
| 301 | !> Initialize virtual measurements: read coordiante arrays and measured |
---|
| 302 | !> variables, set indicies indicating the measurement points, read further |
---|
| 303 | !> attributes, etc.. |
---|
| 304 | !------------------------------------------------------------------------------! |
---|
| 305 | SUBROUTINE vm_init |
---|
| 306 | |
---|
| 307 | USE arrays_3d, & |
---|
| 308 | ONLY: zu, zw |
---|
| 309 | |
---|
| 310 | USE control_parameters, & |
---|
| 311 | ONLY: message_string |
---|
| 312 | |
---|
| 313 | USE grid_variables, & |
---|
| 314 | ONLY: ddx, ddy, dx, dy |
---|
| 315 | |
---|
| 316 | USE indices, & |
---|
| 317 | ONLY: nxl, nxr, nyn, nys |
---|
| 318 | |
---|
| 319 | USE netcdf_data_input_mod, & |
---|
| 320 | ONLY: init_model, input_file_vm, & |
---|
| 321 | netcdf_data_input_get_dimension_length, & |
---|
| 322 | netcdf_data_input_att, netcdf_data_input_var |
---|
| 323 | |
---|
| 324 | USE surface_mod, & |
---|
| 325 | ONLY: get_topography_top_index_ji |
---|
| 326 | |
---|
| 327 | IMPLICIT NONE |
---|
| 328 | |
---|
| 329 | CHARACTER(LEN=5) :: dum !< dummy string indicate station id |
---|
| 330 | CHARACTER(LEN=10), DIMENSION(50) :: measured_variables_file = '' !< array with all measured variables read from NetCDF |
---|
| 331 | CHARACTER(LEN=10), DIMENSION(50) :: measured_variables = '' !< dummy array with all measured variables that are allowed |
---|
| 332 | |
---|
| 333 | LOGICAL :: on_pe !< flag indicating that the respective measurement coordinate is on subdomain |
---|
| 334 | |
---|
| 335 | INTEGER(iwp) :: dim_eutm !< dimension size of UTM easting coordinate |
---|
| 336 | INTEGER(iwp) :: dim_nutm !< dimension size of UTM northing coordinate |
---|
| 337 | INTEGER(iwp) :: dim_ntime !< dimension size of time coordinate |
---|
| 338 | INTEGER(iwp) :: dim_zag !< dimension size of height coordinate |
---|
| 339 | INTEGER(iwp) :: i !< grid index of virtual observation point in x-direction |
---|
| 340 | INTEGER(iwp) :: icov !< index range where observations should be taken in x-direction |
---|
| 341 | INTEGER(iwp) :: ii !< running index over all coordinate points of a measurement |
---|
[3471] | 342 | INTEGER(iwp) :: i_prev !< grid index along x for UTM coordinate at previous observation time step |
---|
[3434] | 343 | INTEGER(iwp) :: is !< grid index of real observation point of the respective station in x-direction |
---|
| 344 | INTEGER(iwp) :: j !< grid index of observation point in x-direction |
---|
| 345 | INTEGER(iwp) :: jcov !< index range where observations should be taken in y-direction |
---|
[3471] | 346 | INTEGER(iwp) :: j_prev !< grid index along y for UTM coordinate at previous observation time step |
---|
[3434] | 347 | INTEGER(iwp) :: js !< grid index of real observation point of the respective station in y-direction |
---|
| 348 | INTEGER(iwp) :: k !< grid index of observation point in x-direction |
---|
| 349 | INTEGER(iwp) :: kcov !< index range where observations should be taken in z-direction |
---|
| 350 | INTEGER(iwp) :: ks !< grid index of real observation point of the respective station in z-direction |
---|
[3471] | 351 | INTEGER(iwp) :: k_prev !< grid index along z for UTM coordinate at previous observation time step |
---|
[3434] | 352 | INTEGER(iwp) :: ksurf !< topography top index |
---|
| 353 | INTEGER(iwp) :: l !< running index over all stations |
---|
| 354 | INTEGER(iwp) :: len_char !< character length of single measured variables without Null character |
---|
| 355 | INTEGER(iwp) :: ll !< running index over all measured variables in file |
---|
| 356 | INTEGER(iwp) :: lll !< running index over all allowed variables |
---|
| 357 | INTEGER(iwp) :: n !< running index over trajectory coordinates |
---|
| 358 | INTEGER(iwp) :: ns !< counter variable for number of observation points on subdomain |
---|
| 359 | INTEGER(iwp) :: t !< running index over number of trajectories |
---|
| 360 | |
---|
| 361 | REAL(wp) :: fill_eutm !< _FillValue for coordinate array E_UTM |
---|
| 362 | REAL(wp) :: fill_nutm !< _FillValue for coordinate array N_UTM |
---|
| 363 | REAL(wp) :: fill_zag !< _FillValue for height coordinate |
---|
| 364 | |
---|
[3437] | 365 | REAL(wp), DIMENSION(:,:), ALLOCATABLE :: e_utm !< easting UTM coordinate, temporary variable |
---|
| 366 | REAL(wp), DIMENSION(:,:), ALLOCATABLE :: n_utm !< northing UTM coordinate, temporary variable, |
---|
| 367 | REAL(wp), DIMENSION(:,:), ALLOCATABLE :: z_ag !< height coordinate relative to origin_z, temporary variable |
---|
[3434] | 368 | ! |
---|
| 369 | !-- Obtain number of virtual measurement stations |
---|
| 370 | CALL netcdf_data_input_att( nvm, char_numstations, id_vm, input_file_vm, & |
---|
| 371 | global_attribute, 'open', '' ) |
---|
| 372 | ! |
---|
| 373 | !-- ALLOCATE data structure |
---|
| 374 | ALLOCATE( vmea(1:nvm) ) |
---|
| 375 | |
---|
[3437] | 376 | ! print*, "nvm", nvm |
---|
[3434] | 377 | ! |
---|
| 378 | !-- Read station coordinates and further attributes. |
---|
| 379 | !-- Note all coordinates are in UTM coordinates. |
---|
| 380 | DO l = 1, nvm |
---|
| 381 | ! |
---|
| 382 | !-- Determine suffix which contains the ID |
---|
| 383 | IF( l < 10 ) THEN |
---|
| 384 | WRITE( dum, '(I1)') l |
---|
| 385 | ELSEIF( l < 100 ) THEN |
---|
| 386 | WRITE( dum, '(I2)') l |
---|
| 387 | ELSEIF( l < 1000 ) THEN |
---|
| 388 | WRITE( dum, '(I3)') l |
---|
| 389 | ELSEIF( l < 10000 ) THEN |
---|
| 390 | WRITE( dum, '(I4)') l |
---|
| 391 | ELSEIF( l < 100000 ) THEN |
---|
| 392 | WRITE( dum, '(I5)') l |
---|
| 393 | ENDIF |
---|
| 394 | |
---|
| 395 | CALL netcdf_data_input_att( vmea(l)%origin_x_obs, char_origx & |
---|
| 396 | // TRIM( dum ), id_vm, '', global_attribute,& |
---|
| 397 | '', '' ) |
---|
| 398 | CALL netcdf_data_input_att( vmea(l)%origin_y_obs, char_origy & |
---|
| 399 | // TRIM( dum ), id_vm, '', global_attribute,& |
---|
| 400 | '', '' ) |
---|
| 401 | CALL netcdf_data_input_att( vmea(l)%site, char_site & |
---|
| 402 | // TRIM( dum ), id_vm, '', global_attribute,& |
---|
| 403 | '', '' ) |
---|
| 404 | CALL netcdf_data_input_att( vmea(l)%feature_type, char_feature & |
---|
| 405 | // TRIM( dum ), id_vm, '', global_attribute,& |
---|
| 406 | '', '' ) |
---|
| 407 | |
---|
| 408 | ! |
---|
| 409 | !--- Set logicals depending on the type of the measurement |
---|
| 410 | IF ( INDEX( vmea(l)%feature_type, type_tspr ) /= 0 ) THEN |
---|
| 411 | vmea(l)%timseries_profile = .TRUE. |
---|
| 412 | ELSEIF ( INDEX( vmea(l)%feature_type, type_ts ) /= 0 ) THEN |
---|
| 413 | vmea(l)%timseries = .TRUE. |
---|
| 414 | ELSEIF ( INDEX( vmea(l)%feature_type, type_traj ) /= 0 ) THEN |
---|
| 415 | vmea(l)%trajectory = .TRUE. |
---|
| 416 | ELSE |
---|
| 417 | ! |
---|
| 418 | !-- Give error message |
---|
| 419 | message_string = 'Attribue featureType = ' // & |
---|
| 420 | TRIM( vmea(l)%feature_type ) // & |
---|
| 421 | ' is not allowed.' |
---|
| 422 | CALL message( 'vm_init', 'PA0000', 1, 2, 0, 6, 0 ) |
---|
| 423 | ENDIF |
---|
| 424 | ! |
---|
| 425 | !-- Read string with all measured variables at this station |
---|
| 426 | measured_variables_file = '' |
---|
| 427 | CALL netcdf_data_input_var( measured_variables_file, & |
---|
| 428 | char_mv // TRIM( dum ), id_vm ) |
---|
| 429 | ! |
---|
| 430 | !-- Count the number of measured variables which match with the variables |
---|
| 431 | !-- which are allowed to be measured in PALM. Please note, for some |
---|
| 432 | !-- NetCDF interal reasons characters end with a NULL, i.e. also empty |
---|
| 433 | !-- characters contain a NULL. Therefore, check the strings for a Null to |
---|
| 434 | !-- get the correct character length in order to compare them with the list |
---|
| 435 | !-- of allowed variables. |
---|
| 436 | vmea(l)%nvar = 0 |
---|
| 437 | DO ll = 1, SIZE( measured_variables_file ) |
---|
| 438 | IF ( measured_variables_file(ll)(1:1) /= CHAR(0) .AND. & |
---|
| 439 | measured_variables_file(ll)(1:1) /= ' ') THEN |
---|
| 440 | ! |
---|
| 441 | !-- Obtain character length of the character |
---|
| 442 | len_char = 1 |
---|
| 443 | DO WHILE ( measured_variables_file(ll)(len_char:len_char) /= CHAR(0)& |
---|
| 444 | .AND. measured_variables_file(ll)(len_char:len_char) /= ' ' ) |
---|
| 445 | len_char = len_char + 1 |
---|
| 446 | ENDDO |
---|
| 447 | len_char = len_char - 1 |
---|
| 448 | ! |
---|
| 449 | !-- Now, compare the measured variable with the list of allowed |
---|
| 450 | !-- variables. |
---|
| 451 | DO lll= 1, SIZE( list_allowed_variables ) |
---|
| 452 | IF ( measured_variables_file(ll)(1:len_char) == & |
---|
| 453 | TRIM( list_allowed_variables(lll) ) ) THEN |
---|
| 454 | vmea(l)%nvar = vmea(l)%nvar + 1 |
---|
| 455 | measured_variables(vmea(l)%nvar) = & |
---|
| 456 | measured_variables_file(ll)(1:len_char) |
---|
| 457 | ENDIF |
---|
| 458 | ENDDO |
---|
| 459 | ENDIF |
---|
| 460 | ENDDO |
---|
| 461 | ! |
---|
| 462 | !-- Allocate array for the measured variables names for the station l. |
---|
| 463 | ALLOCATE( vmea(l)%measured_vars_name(1:vmea(l)%nvar) ) |
---|
| 464 | |
---|
| 465 | DO ll = 1, vmea(l)%nvar |
---|
| 466 | vmea(l)%measured_vars_name(ll) = TRIM( measured_variables(ll) ) |
---|
| 467 | ENDDO |
---|
| 468 | |
---|
[3437] | 469 | ! print*, "numvars", vmea(l)%nvar, vmea(l)%measured_vars_name(1:vmea(l)%nvar) |
---|
[3434] | 470 | ! |
---|
| 471 | !-- For the actual measurement ID read the UTM coordinates. Based on these, |
---|
| 472 | !-- define the index space on each subdomain where measurements should be |
---|
| 473 | !-- taken. Note, the entire coordinate arrays will not be stored on data |
---|
| 474 | !-- type as this would exceed memory requirements, particularly for |
---|
| 475 | !-- trajectory measurements. If no variable will be virtually measured, |
---|
| 476 | !-- skip the reading. |
---|
| 477 | IF ( vmea(l)%nvar > 0 ) THEN |
---|
| 478 | ! |
---|
| 479 | !-- For stationary measurements UTM coordinates are just one value and |
---|
| 480 | !-- its dimension is "station", while for mobile measurements UTM |
---|
| 481 | !-- coordinates are arrays. First, inquire dimension length for |
---|
| 482 | !-- UTM coordinates. |
---|
| 483 | IF ( vmea(l)%trajectory ) THEN |
---|
| 484 | ! |
---|
| 485 | !-- For non-stationary measurements read the number of trajectories |
---|
| 486 | CALL netcdf_data_input_get_dimension_length( id_vm, & |
---|
| 487 | vmea(l)%ntraj, & |
---|
| 488 | "traj" // & |
---|
| 489 | TRIM( dum ) ) |
---|
| 490 | CALL netcdf_data_input_get_dimension_length( id_vm, dim_ntime, & |
---|
| 491 | "ntime" // & |
---|
| 492 | TRIM( dum ) ) |
---|
| 493 | ! |
---|
| 494 | !-- For stationary measurements the dimension for UTM coordinates is 1 |
---|
| 495 | ELSE |
---|
| 496 | vmea(l)%ntraj = 1 |
---|
| 497 | dim_ntime = 1 |
---|
| 498 | ENDIF |
---|
| 499 | |
---|
| 500 | ! |
---|
| 501 | !- Allocate array which defines individual time frame for each |
---|
| 502 | !-- trajectory or station |
---|
| 503 | ALLOCATE( vmea(l)%dim_t(1:vmea(l)%ntraj) ) |
---|
[3437] | 504 | ALLOCATE( vmea(l)%ngp(1:vmea(l)%ntraj) ) |
---|
[3434] | 505 | ! |
---|
| 506 | !-- Allocate temporary arrays for UTM and height coordinates. Note, |
---|
| 507 | !-- on file UTM coordinates might be 1D or 2D variables |
---|
[3437] | 508 | ALLOCATE( e_utm(1:vmea(l)%ntraj,1:dim_ntime) ) |
---|
| 509 | ALLOCATE( n_utm(1:vmea(l)%ntraj,1:dim_ntime) ) |
---|
| 510 | ALLOCATE( z_ag(1:vmea(l)%ntraj,1:dim_ntime) ) |
---|
[3434] | 511 | ! |
---|
| 512 | !-- Read _FillValue attributes |
---|
| 513 | CALL netcdf_data_input_att( fill_eutm, char_fillvalue, & |
---|
| 514 | id_vm, '', .NOT. global_attribute, '', & |
---|
| 515 | char_eutm // TRIM( dum ) ) |
---|
| 516 | CALL netcdf_data_input_att( fill_nutm, char_fillvalue, & |
---|
| 517 | id_vm, '', .NOT. global_attribute, '', & |
---|
| 518 | char_nutm // TRIM( dum ) ) |
---|
| 519 | CALL netcdf_data_input_att( fill_zag, char_fillvalue, & |
---|
| 520 | id_vm, '', .NOT. global_attribute, '', & |
---|
| 521 | char_zag // TRIM( dum ) ) |
---|
| 522 | ! |
---|
| 523 | !-- Read UTM and height coordinates coordinates for all trajectories and |
---|
| 524 | !-- times. |
---|
[3437] | 525 | IF ( vmea(l)%trajectory ) THEN |
---|
| 526 | CALL netcdf_data_input_var( e_utm, char_eutm // TRIM( dum ), id_vm, & |
---|
| 527 | 0, dim_ntime-1, 0, vmea(l)%ntraj-1 ) |
---|
| 528 | CALL netcdf_data_input_var( n_utm, char_nutm // TRIM( dum ), id_vm, & |
---|
| 529 | 0, dim_ntime-1, 0, vmea(l)%ntraj-1 ) |
---|
| 530 | CALL netcdf_data_input_var( z_ag, char_zag // TRIM( dum ), id_vm, & |
---|
| 531 | 0, dim_ntime-1, 0, vmea(l)%ntraj-1 ) |
---|
| 532 | ELSE |
---|
[3471] | 533 | CALL netcdf_data_input_var( e_utm(1,:), char_eutm // TRIM( dum ), id_vm ) |
---|
[3437] | 534 | CALL netcdf_data_input_var( n_utm(1,:), char_nutm // TRIM( dum ), id_vm ) |
---|
| 535 | CALL netcdf_data_input_var( z_ag(1,:), char_zag // TRIM( dum ), id_vm ) |
---|
| 536 | ENDIF |
---|
[3434] | 537 | ! |
---|
| 538 | !-- Based on UTM coordinates, check if the measurement station or parts |
---|
| 539 | !-- of the trajectory is on subdomain. This case, setup grid index space |
---|
| 540 | !-- sample these quantities. |
---|
| 541 | ns = 0 |
---|
| 542 | DO t = 1, vmea(l)%ntraj |
---|
| 543 | ! |
---|
| 544 | !-- Determine the individual time coordinate length for each station and |
---|
| 545 | !-- trajectory. This is required as several stations and trajectories |
---|
| 546 | !-- are merged into one file but they do not have the same number of |
---|
| 547 | !-- points in time, hence, missing values may occur and cannot be |
---|
| 548 | !-- processed further. |
---|
| 549 | vmea(l)%dim_t(t) = 0 |
---|
| 550 | DO n = 1, dim_ntime |
---|
[3437] | 551 | IF ( e_utm(t,n) /= fill_eutm .AND. & |
---|
| 552 | n_utm(t,n) /= fill_nutm .AND. & |
---|
| 553 | z_ag(t,n) /= fill_zag ) vmea(l)%dim_t(t) = n |
---|
[3434] | 554 | ENDDO |
---|
| 555 | ! |
---|
| 556 | !-- First, compute relative x- and y-coordinates with respect to the |
---|
| 557 | !-- lower-left origin of the model domain, which is the difference |
---|
| 558 | !-- betwen UTM coordinates. |
---|
[3494] | 559 | |
---|
[3437] | 560 | e_utm(t,1:vmea(l)%dim_t(t)) = e_utm(t,1:vmea(l)%dim_t(t)) & |
---|
| 561 | - init_model%origin_x |
---|
| 562 | n_utm(t,1:vmea(l)%dim_t(t)) = n_utm(t,1:vmea(l)%dim_t(t)) & |
---|
| 563 | - init_model%origin_y |
---|
[3434] | 564 | ! |
---|
| 565 | !-- Compute grid indices relative to origin and check if these are |
---|
| 566 | !-- on the subdomain. Note, virtual measurements will be taken also |
---|
| 567 | !-- at grid points surrounding the station, hence, check also for |
---|
| 568 | !-- these grid points. |
---|
| 569 | vmea(l)%ngp(t) = 0 |
---|
| 570 | k_prev = -999 |
---|
| 571 | j_prev = -999 |
---|
| 572 | i_prev = -999 |
---|
[3437] | 573 | DO n = 1, vmea(l)%dim_t(t) |
---|
| 574 | is = INT( ( e_utm(t,n) + 0.5_wp * dx ) * ddx, KIND = iwp ) |
---|
| 575 | js = INT( ( n_utm(t,n) + 0.5_wp * dy ) * ddy, KIND = iwp ) |
---|
[3434] | 576 | ! |
---|
| 577 | !-- Is the observation point on subdomain? |
---|
| 578 | on_pe = ( is >= nxl .AND. is <= nxr .AND. & |
---|
| 579 | js >= nys .AND. js <= nyn ) |
---|
| 580 | ! |
---|
| 581 | !-- If the measurement is on subdomain, determine vertical index |
---|
| 582 | !-- which refers to the observation height above ground level. |
---|
| 583 | ks = k_prev |
---|
| 584 | IF ( on_pe ) THEN |
---|
| 585 | ksurf = get_topography_top_index_ji( js, is, 's' ) |
---|
[3437] | 586 | ks = MINLOC( ABS( zu - zw(ksurf) - z_ag(t,n) ), DIM = 1 ) - 1 |
---|
[3434] | 587 | ENDIF |
---|
| 588 | ! |
---|
| 589 | !-- Count the number of observation points in index space on |
---|
| 590 | !-- subdomain. Only increment if grid indices are different from |
---|
| 591 | !-- the previous one. |
---|
| 592 | IF ( on_pe .AND. is /= i_prev .AND. js /= j_prev .AND. & |
---|
| 593 | ks /= k_prev ) THEN |
---|
| 594 | ns = ns + 1 |
---|
| 595 | vmea(l)%ngp(t) = vmea(l)%ngp(t) + 1 |
---|
| 596 | ENDIF |
---|
[3437] | 597 | |
---|
[3434] | 598 | !-- Store arrays for next iteration - avoid double counting |
---|
| 599 | i_prev = is |
---|
| 600 | j_prev = js |
---|
| 601 | k_prev = ks |
---|
| 602 | ENDDO |
---|
| 603 | |
---|
| 604 | ENDDO |
---|
| 605 | |
---|
| 606 | ! |
---|
| 607 | !-- Store number of observation points on subdomain and allocate index |
---|
| 608 | !-- arrays. |
---|
| 609 | vmea(l)%ns = ns |
---|
| 610 | |
---|
| 611 | ALLOCATE( vmea(l)%i(1:vmea(l)%ns) ) |
---|
| 612 | ALLOCATE( vmea(l)%j(1:vmea(l)%ns) ) |
---|
| 613 | ALLOCATE( vmea(l)%k(1:vmea(l)%ns) ) |
---|
| 614 | |
---|
[3437] | 615 | ! print*, "Num ns: ", vmea(l)%ns, "per traj", vmea(l)%ngp(:) |
---|
[3434] | 616 | ! |
---|
| 617 | !-- Repeat the prior loop and save the grid indices relevant for |
---|
| 618 | !-- sampling. |
---|
| 619 | ns = 0 |
---|
| 620 | DO t = 1, vmea(l)%ntraj |
---|
| 621 | ! |
---|
| 622 | !-- Compute grid indices relative to origin and check if these are |
---|
| 623 | !-- on the subdomain. Note, virtual measurements will be taken also |
---|
| 624 | !-- at grid points surrounding the station, hence, check also for |
---|
| 625 | !-- these grid points. |
---|
| 626 | k_prev = -999 |
---|
| 627 | j_prev = -999 |
---|
| 628 | i_prev = -999 |
---|
[3437] | 629 | DO n = 1, vmea(l)%dim_t(t) |
---|
| 630 | is = INT( ( e_utm(t,n) + 0.5_wp * dx ) * ddx, KIND = iwp ) |
---|
| 631 | js = INT( ( n_utm(t,n) + 0.5_wp * dy ) * ddy, KIND = iwp ) |
---|
[3434] | 632 | ! |
---|
| 633 | !-- Is the observation point on subdomain? |
---|
| 634 | on_pe = ( is >= nxl .AND. is <= nxr .AND. & |
---|
| 635 | js >= nys .AND. js <= nyn ) |
---|
| 636 | ! |
---|
| 637 | !-- If the measurement is on subdomain, determine vertical index |
---|
| 638 | !-- which refers to the observation height above ground level. |
---|
| 639 | ks = k_prev |
---|
| 640 | IF ( on_pe ) THEN |
---|
| 641 | ksurf = get_topography_top_index_ji( js, is, 's' ) |
---|
[3437] | 642 | ks = MINLOC( ABS( zu - zw(ksurf) - z_ag(t,n) ), DIM = 1 ) - 1 |
---|
[3434] | 643 | ENDIF |
---|
| 644 | ! |
---|
| 645 | !-- Count the number of observation points in index space on |
---|
| 646 | !-- subdomain. Only increment if grid indices are different from |
---|
| 647 | !-- the previous one. |
---|
| 648 | IF ( on_pe .AND. is /= i_prev .AND. js /= j_prev .AND. & |
---|
| 649 | ks /= k_prev ) THEN |
---|
| 650 | ns = ns + 1 |
---|
| 651 | vmea(l)%i(ns) = is |
---|
| 652 | vmea(l)%j(ns) = js |
---|
| 653 | vmea(l)%k(ns) = ks |
---|
| 654 | ENDIF |
---|
| 655 | ! |
---|
| 656 | !-- Store arrays for next iteration - avoid double counting |
---|
| 657 | i_prev = is |
---|
| 658 | j_prev = js |
---|
| 659 | k_prev = ks |
---|
| 660 | ENDDO |
---|
| 661 | |
---|
| 662 | ENDDO |
---|
| 663 | ! |
---|
| 664 | !-- Allocate array to save the sampled values. |
---|
| 665 | !-- Todo: Is it better to allocate for all variables at a station |
---|
| 666 | !-- and store all the values before writing, or sample the variables |
---|
| 667 | !-- directly in the data output? |
---|
| 668 | ALLOCATE( vmea(l)%measured_vars(1:vmea(l)%nvar,1:vmea(l)%ns) ) |
---|
| 669 | ! |
---|
| 670 | !-- Initialize with _FillValue |
---|
| 671 | vmea(l)%measured_vars(1:vmea(l)%nvar,1:vmea(l)%ns) = vmea(l)%fillout |
---|
| 672 | ! |
---|
| 673 | !-- Deallocate temporary coordinate arrays |
---|
| 674 | IF ( ALLOCATED( e_utm ) ) DEALLOCATE( e_utm ) |
---|
| 675 | IF ( ALLOCATED( n_utm ) ) DEALLOCATE( n_utm ) |
---|
| 676 | IF ( ALLOCATED( z_ag ) ) DEALLOCATE( z_ag ) |
---|
| 677 | ENDIF |
---|
| 678 | ENDDO |
---|
[3471] | 679 | flush(9) |
---|
[3434] | 680 | |
---|
| 681 | ! |
---|
| 682 | !-- Close input file for virtual measurements. Therefore, just call |
---|
| 683 | !-- the read attribute routine with the "close" option. |
---|
| 684 | CALL netcdf_data_input_att( nvm, char_numstations, id_vm, '', & |
---|
| 685 | global_attribute, 'close', '' ) |
---|
| 686 | END SUBROUTINE vm_init |
---|
| 687 | |
---|
| 688 | |
---|
| 689 | !------------------------------------------------------------------------------! |
---|
| 690 | ! Description: |
---|
| 691 | ! ------------ |
---|
| 692 | !> Sampling of the actual quantities along the observation coordinates |
---|
| 693 | !------------------------------------------------------------------------------! |
---|
[3471] | 694 | SUBROUTINE vm_sampling |
---|
[3434] | 695 | |
---|
| 696 | USE arrays_3d !, & |
---|
| 697 | ! ONLY: pt |
---|
[3471] | 698 | |
---|
| 699 | USE surface_mod |
---|
[3434] | 700 | |
---|
| 701 | IMPLICIT NONE |
---|
| 702 | |
---|
| 703 | CHARACTER(LEN=10) :: trimvar !< dummy for the measured variable name |
---|
| 704 | |
---|
| 705 | INTEGER(iwp) :: l !< |
---|
| 706 | INTEGER(iwp) :: m !< |
---|
| 707 | INTEGER(iwp) :: var !< |
---|
[3471] | 708 | |
---|
| 709 | INTEGER(iwp) :: mm, j, i |
---|
[3434] | 710 | |
---|
| 711 | ! |
---|
| 712 | !-- Loop over all stations. For each possible variable loop over all |
---|
| 713 | !-- observation points |
---|
| 714 | DO l = 1, nvm |
---|
| 715 | ! |
---|
| 716 | !-- Loop over all measured variables. Please note, for the moment |
---|
| 717 | !-- the same indices for scalar and velocity components are used. |
---|
| 718 | !-- ToDo: Revise this later. |
---|
[3494] | 719 | DO m = 1, vmea(l)%ns |
---|
| 720 | j = vmea(l)%j(m) |
---|
| 721 | i = vmea(l)%i(m) |
---|
[3471] | 722 | ! |
---|
| 723 | ! IF ( i >= nxl .AND. i <= nxr .AND. & |
---|
| 724 | ! j >= nys .AND. j <= nyn ) THEN |
---|
| 725 | ! IF ( surf_def_h(0)%start_index(j,i) <= & |
---|
| 726 | ! surf_def_h(0)%end_index(j,i) ) THEN |
---|
| 727 | ! mm = surf_def_h(0)%end_index(j,i) |
---|
| 728 | ! |
---|
| 729 | ! surf_def_h(0)%pt_surface(mm) = -99.0 |
---|
| 730 | ! ENDIF |
---|
| 731 | ! ENDIF |
---|
| 732 | ! ENDDO |
---|
| 733 | ! DO var = 1, vmea(l)%nvar |
---|
| 734 | ! trimvar = TRIM( vmea(l)%measured_vars_name(var) ) |
---|
| 735 | ! |
---|
| 736 | ! IF ( TRIM( trimvar ) == 'theta' ) THEN |
---|
| 737 | ! DO m = 1, vmea(l)%ns |
---|
| 738 | ! vmea(l)%measured_vars(var,m) = pt(vmea(l)%k(m),vmea(l)%j(m),vmea(l)%i(m)) |
---|
| 739 | ! ENDDO |
---|
| 740 | ! ENDIF |
---|
| 741 | ! IF ( TRIM( trimvar ) == 'w' ) THEN |
---|
| 742 | ! DO m = 1, vmea(l)%ns |
---|
| 743 | ! vmea(l)%measured_vars(var,m) = w(vmea(l)%k(m),vmea(l)%j(m),vmea(l)%i(m)) |
---|
| 744 | ! ENDDO |
---|
| 745 | ! ENDIF |
---|
| 746 | ! IF ( TRIM( trimvar ) == 'v' ) THEN |
---|
| 747 | ! DO m = 1, vmea(l)%ns |
---|
| 748 | ! vmea(l)%measured_vars(var,m) = v(vmea(l)%k(m),vmea(l)%j(m),vmea(l)%i(m)) |
---|
| 749 | ! ENDDO |
---|
| 750 | ! ENDIF |
---|
| 751 | ! IF ( TRIM( trimvar ) == 'u' ) THEN |
---|
| 752 | ! DO m = 1, vmea(l)%ns |
---|
| 753 | ! vmea(l)%measured_vars(var,m) = u(vmea(l)%k(m),vmea(l)%j(m),vmea(l)%i(m)) |
---|
| 754 | ! ENDDO |
---|
| 755 | ! ENDIF |
---|
[3494] | 756 | ENDDO |
---|
[3434] | 757 | |
---|
| 758 | ENDDO |
---|
| 759 | |
---|
[3471] | 760 | END SUBROUTINE vm_sampling |
---|
[3434] | 761 | |
---|
| 762 | |
---|
[3471] | 763 | END MODULE virtual_measurement_mod |
---|