1 | SUBROUTINE user_init_plant_canopy |
---|
2 | |
---|
3 | !------------------------------------------------------------------------------! |
---|
4 | ! Current revisions: |
---|
5 | ! ----------------- |
---|
6 | ! Output of messages replaced by message handling routine. |
---|
7 | ! |
---|
8 | ! |
---|
9 | ! Former revisions: |
---|
10 | ! ----------------- |
---|
11 | ! $Id: user_init_plant_canopy.f90 274 2009-03-26 15:11:21Z heinze $ |
---|
12 | ! |
---|
13 | ! 211 2008-11-11 04:46:24Z raasch |
---|
14 | ! Former file user_interface.f90 split into one file per subroutine |
---|
15 | ! |
---|
16 | ! Description: |
---|
17 | ! ------------ |
---|
18 | ! Initialisation of the leaf area density array (for scalar grid points) and |
---|
19 | ! the array of the canopy drag coefficient, if the user has not chosen any |
---|
20 | ! of the default cases |
---|
21 | !------------------------------------------------------------------------------! |
---|
22 | |
---|
23 | USE arrays_3d |
---|
24 | USE control_parameters |
---|
25 | USE indices |
---|
26 | USE user |
---|
27 | |
---|
28 | IMPLICIT NONE |
---|
29 | |
---|
30 | INTEGER :: i, j |
---|
31 | |
---|
32 | ! |
---|
33 | !-- Here the user-defined grid initializing actions follow: |
---|
34 | |
---|
35 | ! |
---|
36 | !-- Set the 3D-arrays lad_s and cdc for user defined canopies |
---|
37 | SELECT CASE ( TRIM( canopy_mode ) ) |
---|
38 | |
---|
39 | CASE ( 'block' ) |
---|
40 | ! |
---|
41 | !-- Not allowed here since this is the standard case used in init_3d_model. |
---|
42 | |
---|
43 | CASE ( 'user_defined_canopy_1' ) |
---|
44 | ! |
---|
45 | !-- Here the user can define his own topography. |
---|
46 | !-- The following lines contain an example in that the |
---|
47 | !-- plant canopy extends only over the second half of the |
---|
48 | !-- model domain along x |
---|
49 | ! DO i = nxl-1, nxr+1 |
---|
50 | ! IF ( i >= INT(nx+1/2) ) THEN |
---|
51 | ! DO j = nys-1, nyn+1 |
---|
52 | ! lad_s(:,j,i) = lad(:) |
---|
53 | ! cdc(:,j,i) = drag_coefficient |
---|
54 | ! ENDDO |
---|
55 | ! ELSE |
---|
56 | ! lad_s(:,:,i) = 0.0 |
---|
57 | ! cdc(:,:,i) = 0.0 |
---|
58 | ! ENDIF |
---|
59 | ! ENDDO |
---|
60 | !-- After definition, please |
---|
61 | !-- remove the following three lines! |
---|
62 | message_string = 'canopy_mode "' // canopy_mode // & |
---|
63 | '" not available yet' |
---|
64 | CALL message( 'user_init_plant_canopy', 'UI0007', 0, 1, 0, 6, 0 ) |
---|
65 | |
---|
66 | CASE DEFAULT |
---|
67 | ! |
---|
68 | !-- The DEFAULT case is reached if the parameter canopy_mode contains a |
---|
69 | !-- wrong character string that is neither recognized in init_3d_model nor |
---|
70 | !-- here in user_init_plant_canopy. |
---|
71 | message_string = 'unknown canopy_mode "' // canopy_mode // '"' |
---|
72 | CALL message( 'user_init_plant_canopy', 'UI0008', 1, 2, 0, 6, 0 ) |
---|
73 | |
---|
74 | END SELECT |
---|
75 | |
---|
76 | |
---|
77 | END SUBROUTINE user_init_plant_canopy |
---|
78 | |
---|