1 | SUBROUTINE run_control |
---|
2 | |
---|
3 | !------------------------------------------------------------------------------! |
---|
4 | ! Current revisions: |
---|
5 | ! ----------------- |
---|
6 | ! |
---|
7 | ! |
---|
8 | ! Former revisions: |
---|
9 | ! ----------------- |
---|
10 | ! $Id: run_control.f90 484 2010-02-05 07:36:54Z helmke $ |
---|
11 | ! |
---|
12 | ! 97 2007-06-21 08:23:15Z raasch |
---|
13 | ! Timestep and z_i format changed |
---|
14 | ! |
---|
15 | ! 87 2007-05-22 15:46:47Z raasch |
---|
16 | ! var_hom renamed pr_palm |
---|
17 | ! |
---|
18 | ! 82 2007-04-16 15:40:52Z raasch |
---|
19 | ! Preprocessor strings for different linux clusters changed to "lc", |
---|
20 | ! routine local_flush is used for buffer flushing |
---|
21 | ! |
---|
22 | ! RCS Log replace by Id keyword, revision history cleaned up |
---|
23 | ! |
---|
24 | ! Revision 1.20 2006/06/02 15:23:47 raasch |
---|
25 | ! cpp-directives extended for lctit |
---|
26 | ! |
---|
27 | ! Revision 1.1 1997/08/11 06:25:38 raasch |
---|
28 | ! Initial revision |
---|
29 | ! |
---|
30 | ! |
---|
31 | ! Description: |
---|
32 | ! ------------ |
---|
33 | ! Computation and output of run-control quantities |
---|
34 | !------------------------------------------------------------------------------! |
---|
35 | |
---|
36 | USE cpulog |
---|
37 | USE indices |
---|
38 | USE interfaces |
---|
39 | USE pegrid |
---|
40 | USE statistics |
---|
41 | USE control_parameters |
---|
42 | |
---|
43 | IMPLICIT NONE |
---|
44 | |
---|
45 | CHARACTER (LEN=1) :: change_chr, disturb_chr |
---|
46 | |
---|
47 | ! |
---|
48 | !-- If required, do statistics |
---|
49 | IF ( .NOT. flow_statistics_called ) CALL flow_statistics |
---|
50 | |
---|
51 | ! |
---|
52 | !-- Flow_statistics has its own cpu-time measurement |
---|
53 | CALL cpu_log( log_point(11), 'run_control', 'start' ) |
---|
54 | |
---|
55 | ! |
---|
56 | !-- Output |
---|
57 | IF ( myid == 0 ) THEN |
---|
58 | |
---|
59 | ! |
---|
60 | !-- Check, whether file unit is already open (may have been opened in header |
---|
61 | !-- before) |
---|
62 | CALL check_open( 15 ) |
---|
63 | |
---|
64 | ! |
---|
65 | !-- If required, write header |
---|
66 | IF ( .NOT. run_control_header ) THEN |
---|
67 | WRITE ( 15, 100 ) |
---|
68 | run_control_header = .TRUE. |
---|
69 | ENDIF |
---|
70 | |
---|
71 | ! |
---|
72 | !-- Output the the beginning of the run receives no information about an |
---|
73 | !-- Euler-timestep |
---|
74 | IF ( dt_changed .AND. simulated_time /= 0.0 .AND. & |
---|
75 | timestep_scheme(1:5) /= 'runge' ) THEN |
---|
76 | IF ( timestep_scheme == 'leapfrog' ) THEN |
---|
77 | change_chr = 'L' |
---|
78 | ELSE |
---|
79 | change_chr = 'E' |
---|
80 | ENDIF |
---|
81 | ELSE |
---|
82 | change_chr = ' ' |
---|
83 | ENDIF |
---|
84 | ! |
---|
85 | !-- If required, set disturbance flag |
---|
86 | IF ( disturbance_created ) THEN |
---|
87 | disturb_chr = 'D' |
---|
88 | ELSE |
---|
89 | disturb_chr = ' ' |
---|
90 | ENDIF |
---|
91 | WRITE ( 15, 101 ) runnr, current_timestep_number, simulated_time_chr, & |
---|
92 | simulated_time-INT( simulated_time ), dt_3d, & |
---|
93 | timestep_reason, change_chr, u_max, disturb_chr, & |
---|
94 | v_max, disturb_chr, w_max, hom(nzb,1,pr_palm,0), & |
---|
95 | hom(nzb+8,1,pr_palm,0), hom(nzb+3,1,pr_palm,0), & |
---|
96 | hom(nzb+6,1,pr_palm,0), hom(nzb+4,1,pr_palm,0), & |
---|
97 | hom(nzb+5,1,pr_palm,0), hom(nzb+9,1,pr_palm,0), & |
---|
98 | hom(nzb+10,1,pr_palm,0), u_max_ijk(1:3), & |
---|
99 | v_max_ijk(1:3), w_max_ijk(1:3), & |
---|
100 | advected_distance_x/1000.0, & |
---|
101 | advected_distance_y/1000.0, mgcycles |
---|
102 | ! |
---|
103 | !-- Write buffer contents to disc immediately |
---|
104 | CALL local_flush( 15 ) |
---|
105 | |
---|
106 | ENDIF |
---|
107 | ! |
---|
108 | !-- If required, reset disturbance flag. This has to be done outside the above |
---|
109 | !-- IF-loop, because the flag would otherwise only be reset on PE0 |
---|
110 | IF ( disturbance_created ) disturbance_created = .FALSE. |
---|
111 | |
---|
112 | CALL cpu_log( log_point(11), 'run_control', 'stop' ) |
---|
113 | |
---|
114 | ! |
---|
115 | !-- Formats |
---|
116 | 100 FORMAT (///'Run-control output:'/ & |
---|
117 | &'------------------'// & |
---|
118 | &'RUN ITER. HH:MM:SS.SS DT(E) UMAX VMAX WMAX U', & |
---|
119 | &'* W* THETA* Z_I ENERG. DISTENERG DIVOLD DIV', & |
---|
120 | &'NEW UMAX(KJI) VMAX(KJI) WMAX(KJI) ADVECX ADVECY ', & |
---|
121 | &'MGCYC'/ & |
---|
122 | &'----------------------------------------------------------------', & |
---|
123 | &'----------------------------------------------------------------', & |
---|
124 | &'----------------------------------------------------------------', & |
---|
125 | &'-----') |
---|
126 | 101 FORMAT (I3,1X,I6,1X,A8,F3.2,1X,F8.4,A1,A1,F8.4,A1,F8.4,A1,F8.4,2X,F5.3,2X, & |
---|
127 | F4.2, & |
---|
128 | 2X,F6.3,2X,F6.0,1X,4(E10.3,1X),3(3(I4),1X),F8.3,1X,F8.3,5X,I3) |
---|
129 | |
---|
130 | END SUBROUTINE run_control |
---|