source: palm/trunk/SOURCE/lpm_calc_liquid_water_content.f90 @ 3250

Last change on this file since 3250 was 3241, checked in by raasch, 6 years ago

various changes to avoid compiler warnings (mainly removal of unused variables)

  • Property svn:keywords set to Id
File size: 5.0 KB
Line 
1!> @file lpm_calc_liquid_water_content.f90
2!------------------------------------------------------------------------------!
3! This file is part of the PALM model system.
4!
5! PALM is free software: you can redistribute it and/or modify it under the
6! terms of the GNU General Public License as published by the Free Software
7! Foundation, either version 3 of the License, or (at your option) any later
8! version.
9!
10! PALM is distributed in the hope that it will be useful, but WITHOUT ANY
11! WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR
12! A PARTICULAR PURPOSE.  See the GNU General Public License for more details.
13!
14! You should have received a copy of the GNU General Public License along with
15! PALM. If not, see <http://www.gnu.org/licenses/>.
16!
17! Copyright 1997-2018 Leibniz Universitaet Hannover
18!------------------------------------------------------------------------------!
19!
20! Current revisions:
21! ------------------
22!
23!
24! Former revisions:
25! -----------------
26! $Id: lpm_calc_liquid_water_content.f90 3241 2018-09-12 15:02:00Z sward $
27! unused variables removed
28!
29! 3039 2018-05-24 13:13:11Z schwenkel
30! bugfix for lcm with grid stretching
31!
32! 2718 2018-01-02 08:49:38Z maronga
33! Corrected "Former revisions" section
34!
35! 2696 2017-12-14 17:12:51Z kanani
36! Change in file header (GPL part)
37!
38! 2101 2017-01-05 16:42:31Z suehring
39!
40! 2000 2016-08-20 18:09:15Z knoop
41! Forced header and separation lines into 80 columns
42!
43! 1822 2016-04-07 07:49:42Z hoffmann
44! Unused variables removed.
45!
46! 1682 2015-10-07 23:56:08Z knoop
47! Code annotations made doxygen readable
48!
49! 1359 2014-04-11 17:15:14Z hoffmann
50! New particle structure integrated.
51! Kind definition added to all floating point numbers.
52!
53! 1320 2014-03-20 08:40:49Z raasch
54! ONLY-attribute added to USE-statements,
55! kind-parameters added to all INTEGER and REAL declaration statements,
56! kinds are defined in new module kinds,
57! comment fields (!:) to be used for variable explanations added to
58! all variable declaration statements
59!
60! 1036 2012-10-22 13:43:42Z raasch
61! code put under GPL (PALM 3.9)
62!
63! 849 2012-03-15 10:35:09Z raasch
64! initial revision (former part of advec_particles)
65!
66!
67! Description:
68! ------------
69!> Calculate the liquid water content for each grid box.
70!------------------------------------------------------------------------------!
71 SUBROUTINE lpm_calc_liquid_water_content
72 
73
74    USE arrays_3d,                                                             &
75        ONLY:  dzw, ql, ql_v, ql_vp
76
77    USE cloud_parameters,                                                      &
78        ONLY:  rho_l
79
80    USE constants,                                                             &
81        ONLY:  pi
82
83    USE control_parameters,                                                    &
84        ONLY:  message_string, rho_surface
85
86    USE cpulog,                                                                &
87        ONLY:  cpu_log, log_point_s
88
89    USE grid_variables,                                                        &
90        ONLY:  dx, dy
91
92    USE indices,                                                               &
93        ONLY:  nxl, nxr, nyn, nys, nzb, nzt
94
95    USE kinds
96
97    USE particle_attributes,                                                   &
98        ONLY:  grid_particles, number_of_particles, particles, prt_count
99
100    IMPLICIT NONE
101
102    INTEGER(iwp) ::  i   !<
103    INTEGER(iwp) ::  j   !<
104    INTEGER(iwp) ::  k   !<
105    INTEGER(iwp) ::  n   !<
106
107    CALL cpu_log( log_point_s(45), 'lpm_calc_ql', 'start' )
108
109!
110!-- Set water content initially to zero
111    ql = 0.0_wp;  ql_v = 0.0_wp;  ql_vp = 0.0_wp
112
113!
114!-- Calculate for each grid box
115    DO  i = nxl, nxr
116       DO  j = nys, nyn
117          DO  k = nzb+1, nzt
118
119             number_of_particles = prt_count(k,j,i)
120             IF ( number_of_particles <= 0 )  CYCLE
121             particles => grid_particles(k,j,i)%particles(1:number_of_particles)
122
123!
124!--          Calculate the total volume in the boxes (ql_v, weighting factor
125!--          has to beincluded)
126             DO  n = 1, prt_count(k,j,i)
127                ql_v(k,j,i)  = ql_v(k,j,i)  + particles(n)%weight_factor *  &
128                                              particles(n)%radius**3
129             ENDDO
130
131!
132!--          Calculate the liquid water content
133             IF ( ql_v(k,j,i) /= 0.0_wp )  THEN
134                ql(k,j,i) = ql(k,j,i) + rho_l * 1.33333333_wp * pi *           &
135                                        ql_v(k,j,i) /                          &
136                                        ( rho_surface * dx * dy * dzw(k) )
137
138                IF ( ql(k,j,i) < 0.0_wp )  THEN
139                   WRITE( message_string, * )  'LWC out of range: ' , &
140                                               ql(k,j,i),i,j,k
141                   CALL message( 'lpm_calc_liquid_water_content', '', 2, 2, &
142                                 -1, 6, 1 )
143                ENDIF
144
145             ELSE
146
147                ql(k,j,i) = 0.0_wp
148
149             ENDIF
150
151          ENDDO
152       ENDDO
153    ENDDO
154
155    CALL cpu_log( log_point_s(45), 'lpm_calc_ql', 'stop' )
156
157
158 END SUBROUTINE lpm_calc_liquid_water_content
Note: See TracBrowser for help on using the repository browser.