1 | !> @file indoor_model_mod.f90 |
---|
2 | !--------------------------------------------------------------------------------------------------! |
---|
3 | ! This file is part of the PALM model system. |
---|
4 | ! |
---|
5 | ! PALM is free software: you can redistribute it and/or modify it under the terms of the GNU General |
---|
6 | ! Public License as published by the Free Software Foundation, either version 3 of the License, or |
---|
7 | ! (at your option) any later version. |
---|
8 | ! |
---|
9 | ! PALM is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the |
---|
10 | ! implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General |
---|
11 | ! Public License for more details. |
---|
12 | ! |
---|
13 | ! You should have received a copy of the GNU General Public License along with PALM. If not, see |
---|
14 | ! <http://www.gnu.org/licenses/>. |
---|
15 | ! |
---|
16 | ! Copyright 2018-2020 Leibniz Universitaet Hannover |
---|
17 | ! Copyright 2018-2020 Hochschule Offenburg |
---|
18 | !--------------------------------------------------------------------------------------------------! |
---|
19 | ! |
---|
20 | ! Current revisions: |
---|
21 | ! ----------------- |
---|
22 | ! |
---|
23 | ! |
---|
24 | ! Former revisions: |
---|
25 | ! ----------------- |
---|
26 | ! $Id: indoor_model_mod.f90 4698 2020-09-25 08:37:55Z maronga $ |
---|
27 | ! Fixed faulty characters |
---|
28 | ! |
---|
29 | ! 4687 2020-09-21 19:40:16Z maronga |
---|
30 | ! Bugfix: values of theta_m_t_prev were not stored for individual surfaces and thus re-used by all |
---|
31 | ! surfaces and buildings, which led to excessive indoor temperatures |
---|
32 | ! |
---|
33 | ! 4681 2020-09-16 10:23:06Z pavelkrc |
---|
34 | ! Bugfix for implementation of downward surfaces |
---|
35 | ! |
---|
36 | ! 4671 2020-09-09 20:27:58Z pavelkrc |
---|
37 | ! Implementation of downward facing USM and LSM surfaces |
---|
38 | ! |
---|
39 | ! 4646 2020-08-24 16:02:40Z raasch |
---|
40 | ! file re-formatted to follow the PALM coding standard |
---|
41 | ! |
---|
42 | ! 4481 2020-03-31 18:55:54Z maronga |
---|
43 | ! Change order of dimension in surface array %frac to allow for better vectorization. |
---|
44 | ! |
---|
45 | ! 4441 2020-03-04 19:20:35Z suehring |
---|
46 | ! Major bugfix in calculation of energy demand - floor-area-per-facade was wrongly calculated |
---|
47 | ! leading to unrealistically high energy demands and thus to unreallistically high waste-heat |
---|
48 | ! fluxes. |
---|
49 | ! |
---|
50 | ! 4346 2019-12-18 11:55:56Z motisi |
---|
51 | ! Introduction of wall_flags_total_0, which currently sets bits based on static topography |
---|
52 | ! information used in wall_flags_static_0 |
---|
53 | ! |
---|
54 | ! 4329 2019-12-10 15:46:36Z motisi |
---|
55 | ! Renamed wall_flags_0 to wall_flags_static_0 |
---|
56 | ! |
---|
57 | ! 4310 2019-11-26 19:01:28Z suehring |
---|
58 | ! Remove dt_indoor from namelist input. The indoor model is an hourly-based model, calling it |
---|
59 | ! more/less often lead to inaccurate results. |
---|
60 | ! |
---|
61 | ! 4299 2019-11-22 10:13:38Z suehring |
---|
62 | ! Output of indoor temperature revised (to avoid non-defined values within buildings) |
---|
63 | ! |
---|
64 | ! 4267 2019-10-16 18:58:49Z suehring |
---|
65 | ! Bugfix in initialization, some indices to access building_pars where wrong. |
---|
66 | ! Introduction of seasonal parameters. |
---|
67 | ! |
---|
68 | ! 4246 2019-09-30 09:27:52Z pavelkrc |
---|
69 | ! |
---|
70 | ! |
---|
71 | ! 4242 2019-09-27 12:59:10Z suehring |
---|
72 | ! Bugfix in array index |
---|
73 | ! |
---|
74 | ! 4238 2019-09-25 16:06:01Z suehring |
---|
75 | ! - Bugfix in determination of minimum facade height and in location message |
---|
76 | ! - Bugfix, avoid division by zero |
---|
77 | ! - Some optimization |
---|
78 | ! |
---|
79 | ! 4227 2019-09-10 18:04:34Z gronemeier |
---|
80 | ! implement new palm_date_time_mod |
---|
81 | ! |
---|
82 | ! 4217 2019-09-04 09:47:05Z scharf |
---|
83 | ! Corrected "Former revisions" section |
---|
84 | ! |
---|
85 | ! 4209 2019-09-02 12:00:03Z suehring |
---|
86 | ! - Bugfix in initialization of indoor temperature |
---|
87 | ! - Prescibe default indoor temperature in case it is not given in the namelist input |
---|
88 | ! |
---|
89 | ! 4182 2019-08-21 14:37:54Z scharf |
---|
90 | ! Corrected "Former revisions" section |
---|
91 | ! |
---|
92 | ! 4148 2019-08-08 11:26:00Z suehring |
---|
93 | ! Bugfix in case of non grid-resolved buildings. Further, vertical grid spacing is now considered at |
---|
94 | ! the correct level. |
---|
95 | ! - change calculation of a_m and c_m |
---|
96 | ! - change calculation of u-values (use h_es in building array) |
---|
97 | ! - rename h_tr_... to h_t_... |
---|
98 | ! h_tr_em to h_t_wm |
---|
99 | ! h_tr_op to h_t_wall |
---|
100 | ! h_tr_w to h_t_es |
---|
101 | ! - rename h_ve to h_v |
---|
102 | ! - rename h_is to h_ms |
---|
103 | ! - inserted net_floor_area |
---|
104 | ! - inserted params_waste_heat_h, params_waste_heat_c from building database |
---|
105 | ! in building array |
---|
106 | ! - change calculation of q_waste_heat |
---|
107 | ! - bugfix in averaging mean indoor temperature |
---|
108 | ! |
---|
109 | ! 3759 2019-02-21 15:53:45Z suehring |
---|
110 | ! - Calculation of total building volume |
---|
111 | ! - Several bugfixes |
---|
112 | ! - Calculation of building height revised |
---|
113 | ! |
---|
114 | ! 3745 2019-02-15 18:57:56Z suehring |
---|
115 | ! - remove building_type from module |
---|
116 | ! - initialize parameters for each building individually instead of a bulk initializaion with |
---|
117 | ! identical building type for all |
---|
118 | ! - output revised |
---|
119 | ! - add missing _wp |
---|
120 | ! - some restructuring of variables in building data structure |
---|
121 | ! |
---|
122 | ! 3744 2019-02-15 18:38:58Z suehring |
---|
123 | ! Some interface calls moved to module_interface + cleanup |
---|
124 | ! |
---|
125 | ! 3469 2018-10-30 20:05:07Z kanani |
---|
126 | ! Initial revision (tlang, suehring, kanani, srissman)! |
---|
127 | ! |
---|
128 | ! Authors: |
---|
129 | ! -------- |
---|
130 | ! @author Tobias Lang |
---|
131 | ! @author Jens Pfafferott |
---|
132 | ! @author Farah Kanani-Suehring |
---|
133 | ! @author Matthias Suehring |
---|
134 | ! @author Sascha Rissmann |
---|
135 | ! @author Bjoern Maronga |
---|
136 | ! |
---|
137 | ! |
---|
138 | ! Description: |
---|
139 | ! ------------ |
---|
140 | !> Module for Indoor Climate Model (ICM) |
---|
141 | !> The module is based on the DIN EN ISO 13790 with simplified hour-based procedure. |
---|
142 | !> This model is a equivalent circuit diagram of a three-point RC-model (5R1C). |
---|
143 | !> This module differs between indoor-air temperature an average temperature of indoor surfaces which make it prossible to determine |
---|
144 | !> thermal comfort |
---|
145 | !> the heat transfer between indoor and outdoor is simplified |
---|
146 | |
---|
147 | !> @todo Many statement comments that are given as doxygen comments need to be changed to normal comments |
---|
148 | !> @todo Replace window_area_per_facade by %frac(1,m) for window |
---|
149 | !> @todo emissivity change for window blinds if solar_protection_on=1 |
---|
150 | |
---|
151 | !> @note Do we allow use of integer flags, or only logical flags? (concerns e.g. cooling_on, heating_on) |
---|
152 | !> @note How to write indoor temperature output to pt array? |
---|
153 | !> |
---|
154 | !> @bug Calculation of iwghf_eb and iwghf_eb_window is faulty |
---|
155 | !--------------------------------------------------------------------------------------------------! |
---|
156 | MODULE indoor_model_mod |
---|
157 | |
---|
158 | USE arrays_3d, & |
---|
159 | ONLY: ddzw, & |
---|
160 | dzw, & |
---|
161 | pt |
---|
162 | |
---|
163 | USE control_parameters, & |
---|
164 | ONLY: initializing_actions |
---|
165 | |
---|
166 | USE kinds |
---|
167 | |
---|
168 | USE netcdf_data_input_mod, & |
---|
169 | ONLY: building_id_f, building_type_f |
---|
170 | |
---|
171 | USE palm_date_time_mod, & |
---|
172 | ONLY: get_date_time, northward_equinox, seconds_per_hour, southward_equinox |
---|
173 | |
---|
174 | USE surface_mod, & |
---|
175 | ONLY: surf_usm_h, surf_usm_v |
---|
176 | |
---|
177 | |
---|
178 | IMPLICIT NONE |
---|
179 | |
---|
180 | ! |
---|
181 | !-- Define data structure for buidlings. |
---|
182 | TYPE build |
---|
183 | |
---|
184 | INTEGER(iwp) :: id !< building ID |
---|
185 | INTEGER(iwp) :: kb_max !< highest vertical index of a building |
---|
186 | INTEGER(iwp) :: kb_min !< lowest vertical index of a building |
---|
187 | INTEGER(iwp) :: num_facades_per_building_h = 0 !< total number of horizontal facades elements |
---|
188 | INTEGER(iwp) :: num_facades_per_building_h_l = 0 !< number of horizontal facade elements on local subdomain |
---|
189 | INTEGER(iwp) :: num_facades_per_building_v = 0 !< total number of vertical facades elements |
---|
190 | INTEGER(iwp) :: num_facades_per_building_v_l = 0 !< number of vertical facade elements on local subdomain |
---|
191 | INTEGER(iwp) :: ventilation_int_loads !< [-] allocation of activity in the building |
---|
192 | |
---|
193 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: l_h !< index array linking surface-element orientation index |
---|
194 | !< for horizontal surfaces with building |
---|
195 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: l_v !< index array linking surface-element orientation index |
---|
196 | !< for vertical surfaces with building |
---|
197 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: m_h !< index array linking surface-element index for |
---|
198 | !< horizontal surfaces with building |
---|
199 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: m_v !< index array linking surface-element index for |
---|
200 | !< vertical surfaces with building |
---|
201 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: num_facade_h !< number of horizontal facade elements per buidling |
---|
202 | !< and height level |
---|
203 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: num_facade_v !< number of vertical facades elements per buidling |
---|
204 | !< and height level |
---|
205 | |
---|
206 | |
---|
207 | LOGICAL :: on_pe = .FALSE. !< flag indicating whether a building with certain ID is on local subdomain |
---|
208 | |
---|
209 | REAL(wp) :: air_change_high !< [1/h] air changes per time_utc_hour |
---|
210 | REAL(wp) :: air_change_low !< [1/h] air changes per time_utc_hour |
---|
211 | REAL(wp) :: area_facade !< [m2] area of total facade |
---|
212 | REAL(wp) :: building_height !< building height |
---|
213 | REAL(wp) :: eta_ve !< [-] heat recovery efficiency |
---|
214 | REAL(wp) :: factor_a !< [-] Dynamic parameters specific effective surface according to Table 12; 2.5 |
---|
215 | !< (very light, light and medium), 3.0 (heavy), 3.5 (very heavy) |
---|
216 | REAL(wp) :: factor_c !< [J/(m2 K)] Dynamic parameters inner heatstorage according to Table 12; 80000 |
---|
217 | !< (very light), 110000 (light), 165000 (medium), 260000 (heavy), 370000 (very heavy) |
---|
218 | REAL(wp) :: f_c_win !< [-] shading factor |
---|
219 | REAL(wp) :: fapf !< [m2/m2] floor area per facade |
---|
220 | REAL(wp) :: g_value_win !< [-] SHGC factor |
---|
221 | REAL(wp) :: h_es !< [W/(m2 K)] surface-related heat transfer coefficient between extern and surface |
---|
222 | REAL(wp) :: height_cei_con !< [m] ceiling construction heigth |
---|
223 | REAL(wp) :: height_storey !< [m] storey heigth |
---|
224 | REAL(wp) :: params_waste_heat_c !< [-] anthropogenic heat outputs for cooling e.g. 1.33 for KKM with COP = 3 |
---|
225 | REAL(wp) :: params_waste_heat_h !< [-] anthropogenic heat outputs for heating e.g. 1 - 0.9 = 0.1 for combustion with |
---|
226 | !< eta = 0.9 or -2 for WP with COP = 3 |
---|
227 | REAL(wp) :: phi_c_max !< [W] Max. Cooling capacity (negative) |
---|
228 | REAL(wp) :: phi_h_max !< [W] Max. Heating capacity (positive) |
---|
229 | REAL(wp) :: q_c_max !< [W/m2] Max. Cooling heat flux per netto floor area (negative) |
---|
230 | REAL(wp) :: q_h_max !< [W/m2] Max. Heating heat flux per netto floor area (positive) |
---|
231 | REAL(wp) :: qint_high !< [W/m2] internal heat gains, option Database qint_0-23 |
---|
232 | REAL(wp) :: qint_low !< [W/m2] internal heat gains, option Database qint_0-23 |
---|
233 | REAL(wp) :: lambda_at !< [-] ratio internal surface/floor area chap. 7.2.2.2. |
---|
234 | REAL(wp) :: lambda_layer3 !< [W/(m*K)] Thermal conductivity of the inner layer |
---|
235 | REAL(wp) :: net_floor_area !< [m2] netto ground area |
---|
236 | REAL(wp) :: s_layer3 !< [m] half thickness of the inner layer (layer_3) |
---|
237 | REAL(wp) :: theta_int_c_set !< [degree_C] Max. Setpoint temperature (summer) |
---|
238 | REAL(wp) :: theta_int_h_set !< [degree_C] Max. Setpoint temperature (winter) |
---|
239 | REAL(wp) :: u_value_win !< [W/(m2*K)] transmittance |
---|
240 | REAL(wp) :: vol_tot !< [m3] total building volume |
---|
241 | |
---|
242 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in !< mean building indoor temperature, height dependent |
---|
243 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in_l !< mean building indoor temperature on local subdomain, height dependent |
---|
244 | REAL(wp), DIMENSION(:), ALLOCATABLE :: theta_m_t_prev_h !< [degree_C] value of theta_m_t from previous time step (horizontal) |
---|
245 | REAL(wp), DIMENSION(:), ALLOCATABLE :: theta_m_t_prev_v !< [degree_C] value of theta_m_t from previous time step (vertical) |
---|
246 | REAL(wp), DIMENSION(:), ALLOCATABLE :: volume !< total building volume, height dependent |
---|
247 | REAL(wp), DIMENSION(:), ALLOCATABLE :: vol_frac !< fraction of local on total building volume, height dependent |
---|
248 | REAL(wp), DIMENSION(:), ALLOCATABLE :: vpf !< building volume volume per facade element, height dependent |
---|
249 | |
---|
250 | END TYPE build |
---|
251 | |
---|
252 | TYPE(build), DIMENSION(:), ALLOCATABLE :: buildings !< building array |
---|
253 | |
---|
254 | INTEGER(iwp) :: num_build !< total number of buildings in domain |
---|
255 | ! |
---|
256 | !-- Declare all global variables within the module |
---|
257 | |
---|
258 | REAL(wp), PARAMETER :: dt_indoor = 3600.0_wp !< [s] time interval for indoor-model application, fixed to |
---|
259 | !< 3600.0 due to model requirements |
---|
260 | REAL(wp), PARAMETER :: h_is = 3.45_wp !< [W/(m2 K)] surface-related heat transfer coefficient between |
---|
261 | !< surface and air (chap. 7.2.2.2) |
---|
262 | REAL(wp), PARAMETER :: h_ms = 9.1_wp !< [W/(m2 K)] surface-related heat transfer coefficient between |
---|
263 | !< component and surface (chap. 12.2.2) |
---|
264 | REAL(wp), PARAMETER :: params_f_f = 0.3_wp !< [-] frame ratio chap. 8.3.2.1.1 for buildings with mostly |
---|
265 | !< cooling 2.0_wp |
---|
266 | REAL(wp), PARAMETER :: params_f_w = 0.9_wp !< [-] correction factor (fuer nicht senkrechten Stahlungseinfall |
---|
267 | !< DIN 4108-2 chap.8, (hier konstant, keine WinkelabhÀngigkeit) |
---|
268 | REAL(wp), PARAMETER :: params_f_win = 0.5_wp !< [-] proportion of window area, Database A_win aus |
---|
269 | !< Datenbank 27 window_area_per_facade_percent |
---|
270 | REAL(wp), PARAMETER :: params_solar_protection = 300.0_wp !< [W/m2] chap. G.5.3.1 sun protection closed, if the radiation |
---|
271 | !< on facade exceeds this value |
---|
272 | |
---|
273 | INTEGER(iwp) :: cooling_on !< Indoor cooling flag (0=off, 1=on) |
---|
274 | INTEGER(iwp) :: heating_on !< Indoor heating flag (0=off, 1=on) |
---|
275 | INTEGER(iwp) :: solar_protection_off !< Solar protection off |
---|
276 | INTEGER(iwp) :: solar_protection_on !< Solar protection on |
---|
277 | |
---|
278 | |
---|
279 | REAL(wp) :: a_m !< [m2] the effective mass-related area |
---|
280 | REAL(wp) :: air_change !< [1/h] Airflow |
---|
281 | REAL(wp) :: c_m !< [J/K] internal heat storage capacity |
---|
282 | REAL(wp) :: facade_element_area !< [m2_facade] building surface facade |
---|
283 | REAL(wp) :: floor_area_per_facade !< [m2/m2] floor area per facade area |
---|
284 | REAL(wp) :: h_t_1 !< [W/K] Heat transfer coefficient auxiliary variable 1 |
---|
285 | REAL(wp) :: h_t_2 !< [W/K] Heat transfer coefficient auxiliary variable 2 |
---|
286 | REAL(wp) :: h_t_3 !< [W/K] Heat transfer coefficient auxiliary variable 3 |
---|
287 | REAL(wp) :: h_t_es !< [W/K] heat transfer coefficient of doors, windows, curtain walls and |
---|
288 | !< glazed walls (assumption: thermal mass=0) |
---|
289 | REAL(wp) :: h_t_is !< [W/K] thermal coupling conductance (Thermischer Kopplungsleitwert) |
---|
290 | REAL(wp) :: h_t_ms !< [W/K] Heat transfer conductance term (got with h_t_wm the thermal mass) |
---|
291 | REAL(wp) :: h_t_wall !< [W/K] heat transfer coefficient of opaque components (assumption: got all |
---|
292 | !< thermal mass) contains of h_t_wm and h_t_ms |
---|
293 | REAL(wp) :: h_t_wm !< [W/K] Heat transfer coefficient of the emmision (got with h_t_ms the |
---|
294 | !< thermal mass) |
---|
295 | REAL(wp) :: h_v !< [W/K] heat transfer of ventilation |
---|
296 | REAL(wp) :: indoor_volume_per_facade !< [m3] indoor air volume per facade element |
---|
297 | REAL(wp) :: initial_indoor_temperature = 293.15 !< [K] initial indoor temperature (namelist parameter) |
---|
298 | REAL(wp) :: net_sw_in !< [W/m2] net short-wave radiation |
---|
299 | REAL(wp) :: phi_hc_nd !< [W] heating demand and/or cooling demand |
---|
300 | REAL(wp) :: phi_hc_nd_10 !< [W] heating demand and/or cooling demand for heating or cooling |
---|
301 | REAL(wp) :: phi_hc_nd_ac !< [W] actual heating demand and/or cooling demand |
---|
302 | REAL(wp) :: phi_hc_nd_un !< [W] unlimited heating demand and/or cooling demand which is necessary to |
---|
303 | !< reach the demanded required temperature (heating is positive, |
---|
304 | !< cooling is negative) |
---|
305 | REAL(wp) :: phi_ia !< [W] internal air load = internal loads * 0.5, Eq. (C.1) |
---|
306 | REAL(wp) :: phi_m !< [W] mass specific thermal load (internal and external) |
---|
307 | REAL(wp) :: phi_mtot !< [W] total mass specific thermal load (internal and external) |
---|
308 | REAL(wp) :: phi_sol !< [W] solar loads |
---|
309 | REAL(wp) :: phi_st !< [W] mass specific thermal load implied non thermal mass |
---|
310 | REAL(wp) :: q_wall_win !< [W/m2]heat flux from indoor into wall/window |
---|
311 | REAL(wp) :: q_waste_heat !< [W/m2]waste heat, sum of waste heat over the roof to Palm |
---|
312 | |
---|
313 | REAL(wp) :: q_c_m !< [W] Energy of thermal storage mass specific thermal load for internal |
---|
314 | !< and external heatsources (for energy bilanz) |
---|
315 | REAL(wp) :: q_c_st !< [W] Energy of thermal storage mass specific thermal load implied non |
---|
316 | !< thermal mass (for energy bilanz) |
---|
317 | REAL(wp) :: q_int !< [W] Energy of internal air load (for energy bilanz) |
---|
318 | REAL(wp) :: q_sol !< [W] Energy of solar (for energy bilanz) |
---|
319 | REAL(wp) :: q_trans !< [W] Energy of transmission (for energy bilanz) |
---|
320 | REAL(wp) :: q_vent !< [W] Energy of ventilation (for energy bilanz) |
---|
321 | |
---|
322 | REAL(wp) :: schedule_d !< [-] activation for internal loads (low or high + low) |
---|
323 | REAL(wp) :: skip_time_do_indoor = 0.0_wp !< [s] Indoor model is not called before this time |
---|
324 | REAL(wp) :: theta_air !< [degree_C] air temperature of the RC-node |
---|
325 | REAL(wp) :: theta_air_0 !< [degree_C] air temperature of the RC-node in equilibrium |
---|
326 | REAL(wp) :: theta_air_10 !< [degree_C] air temperature of the RC-node from a heating capacity |
---|
327 | !< of 10 W/m2 |
---|
328 | REAL(wp) :: theta_air_ac !< [degree_C] actual room temperature after heating/cooling |
---|
329 | REAL(wp) :: theta_air_set !< [degree_C] Setpoint_temperature for the room |
---|
330 | REAL(wp) :: theta_m !< [degree_C} inner temperature of the RC-node |
---|
331 | REAL(wp) :: theta_m_t !< [degree_C] (Fictive) component temperature during timestep |
---|
332 | REAL(wp) :: theta_op !< [degree_C] operative temperature |
---|
333 | REAL(wp) :: theta_s !< [degree_C] surface temperature of the RC-node |
---|
334 | REAL(wp) :: time_indoor = 0.0_wp !< [s] time since last call of indoor model |
---|
335 | REAL(wp) :: total_area !< [m2] area of all surfaces pointing to zone |
---|
336 | REAL(wp) :: window_area_per_facade !< [m2] window area per facade element |
---|
337 | |
---|
338 | ! |
---|
339 | !-- Definition of seasonal parameters, summer and winter, for different building types |
---|
340 | REAL(wp), DIMENSION(0:1,1:7) :: summer_pars = RESHAPE( (/ & ! building_type 1 |
---|
341 | 0.5_wp, & ! basical airflow without occupancy of the room |
---|
342 | 2.0_wp, & ! additional airflow depend of occupancy of the room |
---|
343 | 0.5_wp, & ! building_type 2: basical airflow without occupancy |
---|
344 | ! of the room |
---|
345 | 2.0_wp, & ! additional airflow depend of occupancy of the room |
---|
346 | 0.8_wp, & ! building_type 3: basical airflow without occupancy |
---|
347 | ! of the room |
---|
348 | 2.0_wp, & ! additional airflow depend of occupancy of the room |
---|
349 | 0.1_wp, & ! building_type 4: basical airflow without occupancy |
---|
350 | ! of the room |
---|
351 | 1.5_wp, & ! additional airflow depend of occupancy of the room |
---|
352 | 0.1_wp, & ! building_type 5: basical airflow without occupancy |
---|
353 | ! of the room |
---|
354 | 1.5_wp, & ! additional airflow depend of occupancy of the room |
---|
355 | 0.1_wp, & ! building_type 6: basical airflow without occupancy |
---|
356 | ! of the room |
---|
357 | 1.5_wp, & ! additional airflow depend of occupancy of the room |
---|
358 | 0.1_wp, & ! building_type 7: basical airflow without occupancy |
---|
359 | ! of the room |
---|
360 | 1.5_wp & ! additional airflow depend of occupancy of the room |
---|
361 | /), (/ 2, 7 /) ) |
---|
362 | |
---|
363 | REAL(wp), DIMENSION(0:1,1:7) :: winter_pars = RESHAPE( (/ & ! building_type 1 |
---|
364 | 0.1_wp, & ! basical airflow without occupancy of the room |
---|
365 | 0.5_wp, & ! additional airflow depend of occupancy of the room |
---|
366 | 0.1_wp, & ! building_type 2: basical airflow without occupancy |
---|
367 | ! of the room |
---|
368 | 0.5_wp, & ! additional airflow depend of occupancy of the room |
---|
369 | 0.1_wp, & ! building_type 3: basical airflow without occupancy |
---|
370 | ! of the room |
---|
371 | 0.5_wp, & ! additional airflow depend of occupancy of the room |
---|
372 | 0.1_wp, & ! building_type 4: basical airflow without occupancy |
---|
373 | ! of the room |
---|
374 | 1.5_wp, & ! additional airflow depend of occupancy of the room |
---|
375 | 0.1_wp, & ! building_type 5: basical airflow without occupancy |
---|
376 | ! of the room |
---|
377 | 1.5_wp, & ! additional airflow depend of occupancy of the room |
---|
378 | 0.1_wp, & ! building_type 6: basical airflow without occupancy |
---|
379 | ! of the room |
---|
380 | 1.5_wp, & ! additional airflow depend of occupancy of the room |
---|
381 | 0.1_wp, & ! building_type 7: basical airflow without occupancy |
---|
382 | ! of the room |
---|
383 | 1.5_wp & ! additional airflow depend of occupancy of the room |
---|
384 | /), (/ 2, 7 /) ) |
---|
385 | |
---|
386 | SAVE |
---|
387 | |
---|
388 | |
---|
389 | PRIVATE |
---|
390 | |
---|
391 | ! |
---|
392 | !-- Add INTERFACES that must be available to other modules |
---|
393 | PUBLIC im_init, im_main_heatcool, im_parin, im_define_netcdf_grid, im_check_data_output, & |
---|
394 | im_data_output_3d, im_check_parameters |
---|
395 | |
---|
396 | |
---|
397 | ! |
---|
398 | !-- Add VARIABLES that must be available to other modules |
---|
399 | PUBLIC dt_indoor, skip_time_do_indoor, time_indoor |
---|
400 | |
---|
401 | ! |
---|
402 | !-- PALM interfaces: |
---|
403 | !-- Data output checks for 2D/3D data to be done in check_parameters |
---|
404 | INTERFACE im_check_data_output |
---|
405 | MODULE PROCEDURE im_check_data_output |
---|
406 | END INTERFACE im_check_data_output |
---|
407 | ! |
---|
408 | !-- Input parameter checks to be done in check_parameters |
---|
409 | INTERFACE im_check_parameters |
---|
410 | MODULE PROCEDURE im_check_parameters |
---|
411 | END INTERFACE im_check_parameters |
---|
412 | ! |
---|
413 | !-- Data output of 3D data |
---|
414 | INTERFACE im_data_output_3d |
---|
415 | MODULE PROCEDURE im_data_output_3d |
---|
416 | END INTERFACE im_data_output_3d |
---|
417 | |
---|
418 | ! |
---|
419 | !-- Definition of data output quantities |
---|
420 | INTERFACE im_define_netcdf_grid |
---|
421 | MODULE PROCEDURE im_define_netcdf_grid |
---|
422 | END INTERFACE im_define_netcdf_grid |
---|
423 | ! |
---|
424 | ! ! |
---|
425 | ! !-- Output of information to the header file |
---|
426 | ! INTERFACE im_header |
---|
427 | ! MODULE PROCEDURE im_header |
---|
428 | ! END INTERFACE im_header |
---|
429 | ! |
---|
430 | !-- Calculations for indoor temperatures |
---|
431 | INTERFACE im_calc_temperatures |
---|
432 | MODULE PROCEDURE im_calc_temperatures |
---|
433 | END INTERFACE im_calc_temperatures |
---|
434 | ! |
---|
435 | !-- Initialization actions |
---|
436 | INTERFACE im_init |
---|
437 | MODULE PROCEDURE im_init |
---|
438 | END INTERFACE im_init |
---|
439 | ! |
---|
440 | !-- Main part of indoor model |
---|
441 | INTERFACE im_main_heatcool |
---|
442 | MODULE PROCEDURE im_main_heatcool |
---|
443 | END INTERFACE im_main_heatcool |
---|
444 | ! |
---|
445 | !-- Reading of NAMELIST parameters |
---|
446 | INTERFACE im_parin |
---|
447 | MODULE PROCEDURE im_parin |
---|
448 | END INTERFACE im_parin |
---|
449 | |
---|
450 | CONTAINS |
---|
451 | |
---|
452 | !--------------------------------------------------------------------------------------------------! |
---|
453 | ! Description: |
---|
454 | ! ------------ |
---|
455 | !< Calculation of the air temperatures and mean radiation temperature. |
---|
456 | !< This is basis for the operative temperature. |
---|
457 | !< Based on a Crank-Nicholson scheme with a timestep of a hour. |
---|
458 | !--------------------------------------------------------------------------------------------------! |
---|
459 | SUBROUTINE im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
460 | near_facade_temperature, phi_hc_nd_dummy, theta_m_t_prev ) |
---|
461 | |
---|
462 | INTEGER(iwp) :: i |
---|
463 | INTEGER(iwp) :: j |
---|
464 | INTEGER(iwp) :: k |
---|
465 | |
---|
466 | REAL(wp) :: indoor_wall_window_temperature !< weighted temperature of innermost wall/window layer |
---|
467 | REAL(wp) :: near_facade_temperature |
---|
468 | REAL(wp) :: phi_hc_nd_dummy |
---|
469 | REAL(wp), INTENT(IN) :: theta_m_t_prev |
---|
470 | ! |
---|
471 | !-- Calculation of total mass specific thermal load (internal and external) |
---|
472 | phi_mtot = ( phi_m + h_t_wm * indoor_wall_window_temperature & |
---|
473 | + h_t_3 * ( phi_st + h_t_es * pt(k,j,i) & |
---|
474 | + h_t_1 * & |
---|
475 | ( ( ( phi_ia + phi_hc_nd_dummy ) / h_v ) & |
---|
476 | + near_facade_temperature ) & |
---|
477 | ) / h_t_2 & |
---|
478 | ) !< [degree_C] Eq. (C.5) |
---|
479 | ! |
---|
480 | !-- Calculation of component temperature at current timestep |
---|
481 | theta_m_t = ( ( theta_m_t_prev & |
---|
482 | * ( ( c_m / 3600.0_wp ) - 0.5_wp * ( h_t_3 + h_t_wm ) ) & |
---|
483 | + phi_mtot & |
---|
484 | ) & |
---|
485 | / ( ( c_m / 3600.0_wp ) + 0.5_wp * ( h_t_3 + h_t_wm ) ) & |
---|
486 | ) !< [degree_C] Eq. (C.4) |
---|
487 | ! |
---|
488 | !-- Calculation of mean inner temperature for the RC-node in current timestep |
---|
489 | theta_m = ( theta_m_t + theta_m_t_prev ) * 0.5_wp !< [degree_C] Eq. (C.9) |
---|
490 | |
---|
491 | ! |
---|
492 | !-- Calculation of mean surface temperature of the RC-node in current timestep |
---|
493 | theta_s = ( ( h_t_ms * theta_m + phi_st + h_t_es * pt(k,j,i) & |
---|
494 | + h_t_1 * ( near_facade_temperature & |
---|
495 | + ( phi_ia + phi_hc_nd_dummy ) / h_v ) & |
---|
496 | ) & |
---|
497 | / ( h_t_ms + h_t_es + h_t_1 ) & |
---|
498 | ) !< [degree_C] Eq. (C.10) |
---|
499 | |
---|
500 | ! |
---|
501 | !-- Calculation of the air temperature of the RC-node |
---|
502 | |
---|
503 | |
---|
504 | theta_air = ( h_t_is * theta_s + h_v * near_facade_temperature + phi_ia + phi_hc_nd_dummy ) / & |
---|
505 | ( h_t_is + h_v ) !< [degree_C] Eq. (C.11) |
---|
506 | |
---|
507 | |
---|
508 | END SUBROUTINE im_calc_temperatures |
---|
509 | |
---|
510 | |
---|
511 | !--------------------------------------------------------------------------------------------------! |
---|
512 | ! Description: |
---|
513 | ! ------------ |
---|
514 | !> Initialization of the indoor model. |
---|
515 | !> Static information are calculated here, e.g. building parameters and geometrical information, |
---|
516 | !> anything that doesn't change in time. |
---|
517 | ! |
---|
518 | !-- Input values |
---|
519 | !-- Input datas from Palm, M4 |
---|
520 | ! i_global --> net_sw_in !< global radiation [W/m2] |
---|
521 | ! theta_e --> pt(k,j,i) !< undisturbed outside temperature, 1. PALM volume, for windows |
---|
522 | ! theta_sup = theta_f --> surf_usm_h%pt_10cm(m) |
---|
523 | ! surf_usm_v(l)%pt_10cm(m) !< Air temperature, facade near (10cm) air temperature from |
---|
524 | !< 1. Palm volume |
---|
525 | ! theta_node --> t_wall_h(nzt_wall,m) |
---|
526 | ! t_wall_v(l)%t(nzt_wall,m) !< Temperature of innermost wall layer, for opaque wall |
---|
527 | !--------------------------------------------------------------------------------------------------! |
---|
528 | SUBROUTINE im_init |
---|
529 | |
---|
530 | USE control_parameters, & |
---|
531 | ONLY: message_string, time_since_reference_point |
---|
532 | |
---|
533 | USE indices, & |
---|
534 | ONLY: nxl, nxr, nyn, nys, nzb, nzt, wall_flags_total_0 |
---|
535 | |
---|
536 | USE grid_variables, & |
---|
537 | ONLY: dx, dy |
---|
538 | |
---|
539 | USE pegrid |
---|
540 | |
---|
541 | USE surface_mod, & |
---|
542 | ONLY: surf_usm_h, surf_usm_v |
---|
543 | |
---|
544 | USE urban_surface_mod, & |
---|
545 | ONLY: building_pars, building_type |
---|
546 | |
---|
547 | INTEGER(iwp) :: bt !< local building type |
---|
548 | INTEGER(iwp) :: day_of_year !< day of the year |
---|
549 | INTEGER(iwp) :: i !< running index along x-direction |
---|
550 | INTEGER(iwp) :: j !< running index along y-direction |
---|
551 | INTEGER(iwp) :: k !< running index along z-direction |
---|
552 | INTEGER(iwp) :: l !< running index for surface-element orientation |
---|
553 | INTEGER(iwp) :: m !< running index surface elements |
---|
554 | INTEGER(iwp) :: n !< building index |
---|
555 | INTEGER(iwp) :: nb !< building index |
---|
556 | |
---|
557 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids !< building IDs on entire model domain |
---|
558 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids_final !< building IDs on entire model domain, |
---|
559 | !< multiple occurences are sorted out |
---|
560 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids_final_tmp !< temporary array used for resizing |
---|
561 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids_l !< building IDs on local subdomain |
---|
562 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids_l_tmp !< temporary array used to resize array of building IDs |
---|
563 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: displace_dum !< displacements of start addresses, used for MPI_ALLGATHERV |
---|
564 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: k_max_l !< highest vertical index of a building on subdomain |
---|
565 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: k_min_l !< lowest vertical index of a building on subdomain |
---|
566 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: n_fa !< counting array |
---|
567 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: num_facades_h !< dummy array used for summing-up total number of |
---|
568 | !< horizontal facade elements |
---|
569 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: num_facades_v !< dummy array used for summing-up total number of |
---|
570 | !< vertical facade elements |
---|
571 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: receive_dum_h !< dummy array used for MPI_ALLREDUCE |
---|
572 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: receive_dum_v !< dummy array used for MPI_ALLREDUCE |
---|
573 | |
---|
574 | INTEGER(iwp), DIMENSION(0:numprocs-1) :: num_buildings !< number of buildings with different ID on entire model domain |
---|
575 | INTEGER(iwp), DIMENSION(0:numprocs-1) :: num_buildings_l !< number of buildings with different ID on local subdomain |
---|
576 | |
---|
577 | REAL(wp) :: u_tmp !< dummy for temporary calculation of u-value without h_is |
---|
578 | REAL(wp) :: du_tmp !< 1/u_tmp |
---|
579 | REAL(wp) :: du_win_tmp !< 1/building(nb)%u_value_win |
---|
580 | REAL(wp) :: facade_area_v !< dummy to compute the total facade area from vertical walls |
---|
581 | |
---|
582 | REAL(wp), DIMENSION(:), ALLOCATABLE :: volume !< total building volume at each discrete height level |
---|
583 | REAL(wp), DIMENSION(:), ALLOCATABLE :: volume_l !< total building volume at each discrete height level, |
---|
584 | !< on local subdomain |
---|
585 | |
---|
586 | CALL location_message( 'initializing indoor model', 'start' ) |
---|
587 | ! |
---|
588 | !-- Initializing of indoor model is only possible if buildings can be distinguished by their IDs. |
---|
589 | IF ( .NOT. building_id_f%from_file ) THEN |
---|
590 | message_string = 'Indoor model requires information about building_id' |
---|
591 | CALL message( 'im_init', 'PA0999', 1, 2, 0, 6, 0 ) |
---|
592 | ENDIF |
---|
593 | ! |
---|
594 | !-- Determine number of different building IDs on local subdomain. |
---|
595 | num_buildings_l = 0 |
---|
596 | num_buildings = 0 |
---|
597 | ALLOCATE( build_ids_l(1) ) |
---|
598 | DO i = nxl, nxr |
---|
599 | DO j = nys, nyn |
---|
600 | IF ( building_id_f%var(j,i) /= building_id_f%fill ) THEN |
---|
601 | IF ( num_buildings_l(myid) > 0 ) THEN |
---|
602 | IF ( ANY( building_id_f%var(j,i) == build_ids_l ) ) THEN |
---|
603 | CYCLE |
---|
604 | ELSE |
---|
605 | num_buildings_l(myid) = num_buildings_l(myid) + 1 |
---|
606 | ! |
---|
607 | !-- Resize array with different local building ids |
---|
608 | ALLOCATE( build_ids_l_tmp(1:SIZE(build_ids_l)) ) |
---|
609 | build_ids_l_tmp = build_ids_l |
---|
610 | DEALLOCATE( build_ids_l ) |
---|
611 | ALLOCATE( build_ids_l(1:num_buildings_l(myid)) ) |
---|
612 | build_ids_l(1:num_buildings_l(myid)-1) = & |
---|
613 | build_ids_l_tmp(1:num_buildings_l(myid)-1) |
---|
614 | build_ids_l(num_buildings_l(myid)) = building_id_f%var(j,i) |
---|
615 | DEALLOCATE( build_ids_l_tmp ) |
---|
616 | ENDIF |
---|
617 | ! |
---|
618 | !-- First occuring building id on PE |
---|
619 | ELSE |
---|
620 | num_buildings_l(myid) = num_buildings_l(myid) + 1 |
---|
621 | build_ids_l(1) = building_id_f%var(j,i) |
---|
622 | ENDIF |
---|
623 | ENDIF |
---|
624 | ENDDO |
---|
625 | ENDDO |
---|
626 | ! |
---|
627 | !-- Determine number of building IDs for the entire domain. (Note, building IDs can appear multiple |
---|
628 | !-- times as buildings might be distributed over several PEs.) |
---|
629 | #if defined( __parallel ) |
---|
630 | CALL MPI_ALLREDUCE( num_buildings_l, num_buildings, numprocs, MPI_INTEGER, MPI_SUM, comm2d, & |
---|
631 | ierr ) |
---|
632 | #else |
---|
633 | num_buildings = num_buildings_l |
---|
634 | #endif |
---|
635 | ALLOCATE( build_ids(1:SUM(num_buildings)) ) |
---|
636 | ! |
---|
637 | !-- Gather building IDs. Therefore, first, determine displacements used required for MPI_GATHERV |
---|
638 | !-- call. |
---|
639 | ALLOCATE( displace_dum(0:numprocs-1) ) |
---|
640 | displace_dum(0) = 0 |
---|
641 | DO i = 1, numprocs-1 |
---|
642 | displace_dum(i) = displace_dum(i-1) + num_buildings(i-1) |
---|
643 | ENDDO |
---|
644 | |
---|
645 | #if defined( __parallel ) |
---|
646 | CALL MPI_ALLGATHERV( build_ids_l(1:num_buildings_l(myid)), & |
---|
647 | num_buildings(myid), & |
---|
648 | MPI_INTEGER, & |
---|
649 | build_ids, & |
---|
650 | num_buildings, & |
---|
651 | displace_dum, & |
---|
652 | MPI_INTEGER, & |
---|
653 | comm2d, ierr ) |
---|
654 | |
---|
655 | DEALLOCATE( displace_dum ) |
---|
656 | |
---|
657 | #else |
---|
658 | build_ids = build_ids_l |
---|
659 | #endif |
---|
660 | ! |
---|
661 | !-- Note: in parallel mode, building IDs can occur mutliple times, as each PE has send its own ids. |
---|
662 | !-- Therefore, sort out building IDs which appear multiple times. |
---|
663 | num_build = 0 |
---|
664 | DO n = 1, SIZE(build_ids) |
---|
665 | |
---|
666 | IF ( ALLOCATED(build_ids_final) ) THEN |
---|
667 | IF ( ANY( build_ids(n) == build_ids_final ) ) THEN |
---|
668 | CYCLE |
---|
669 | ELSE |
---|
670 | num_build = num_build + 1 |
---|
671 | ! |
---|
672 | !-- Resize |
---|
673 | ALLOCATE( build_ids_final_tmp(1:num_build) ) |
---|
674 | build_ids_final_tmp(1:num_build-1) = build_ids_final(1:num_build-1) |
---|
675 | DEALLOCATE( build_ids_final ) |
---|
676 | ALLOCATE( build_ids_final(1:num_build) ) |
---|
677 | build_ids_final(1:num_build-1) = build_ids_final_tmp(1:num_build-1) |
---|
678 | build_ids_final(num_build) = build_ids(n) |
---|
679 | DEALLOCATE( build_ids_final_tmp ) |
---|
680 | ENDIF |
---|
681 | ELSE |
---|
682 | num_build = num_build + 1 |
---|
683 | ALLOCATE( build_ids_final(1:num_build) ) |
---|
684 | build_ids_final(num_build) = build_ids(n) |
---|
685 | ENDIF |
---|
686 | ENDDO |
---|
687 | |
---|
688 | ! |
---|
689 | !-- Allocate building-data structure array. Note, this is a global array and all building IDs on |
---|
690 | !-- domain are known by each PE. Further attributes, e.g. height-dependent arrays, however, are only |
---|
691 | !-- allocated on PEs where the respective building is present (in order to reduce memory demands). |
---|
692 | ALLOCATE( buildings(1:num_build) ) |
---|
693 | |
---|
694 | ! |
---|
695 | !-- Store building IDs and check if building with certain ID is present on subdomain. |
---|
696 | DO nb = 1, num_build |
---|
697 | buildings(nb)%id = build_ids_final(nb) |
---|
698 | |
---|
699 | IF ( ANY( building_id_f%var(nys:nyn,nxl:nxr) == buildings(nb)%id ) ) & |
---|
700 | buildings(nb)%on_pe = .TRUE. |
---|
701 | ENDDO |
---|
702 | ! |
---|
703 | !-- Determine the maximum vertical dimension occupied by each building. |
---|
704 | ALLOCATE( k_min_l(1:num_build) ) |
---|
705 | ALLOCATE( k_max_l(1:num_build) ) |
---|
706 | k_min_l = nzt + 1 |
---|
707 | k_max_l = 0 |
---|
708 | |
---|
709 | DO i = nxl, nxr |
---|
710 | DO j = nys, nyn |
---|
711 | IF ( building_id_f%var(j,i) /= building_id_f%fill ) THEN |
---|
712 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM=1 ) |
---|
713 | DO k = nzb, nzt+1 |
---|
714 | ! |
---|
715 | !-- Check if grid point belongs to a building. |
---|
716 | IF ( BTEST( wall_flags_total_0(k,j,i), 6 ) ) THEN |
---|
717 | k_min_l(nb) = MIN( k_min_l(nb), k ) |
---|
718 | k_max_l(nb) = MAX( k_max_l(nb), k ) |
---|
719 | ENDIF |
---|
720 | |
---|
721 | ENDDO |
---|
722 | ENDIF |
---|
723 | ENDDO |
---|
724 | ENDDO |
---|
725 | |
---|
726 | #if defined( __parallel ) |
---|
727 | CALL MPI_ALLREDUCE( k_min_l(:), buildings(:)%kb_min, num_build, MPI_INTEGER, MPI_MIN, comm2d, & |
---|
728 | ierr ) |
---|
729 | CALL MPI_ALLREDUCE( k_max_l(:), buildings(:)%kb_max, num_build, MPI_INTEGER, MPI_MAX, comm2d, & |
---|
730 | ierr ) |
---|
731 | #else |
---|
732 | buildings(:)%kb_min = k_min_l(:) |
---|
733 | buildings(:)%kb_max = k_max_l(:) |
---|
734 | #endif |
---|
735 | |
---|
736 | DEALLOCATE( k_min_l ) |
---|
737 | DEALLOCATE( k_max_l ) |
---|
738 | ! |
---|
739 | !-- Calculate building height. |
---|
740 | DO nb = 1, num_build |
---|
741 | buildings(nb)%building_height = 0.0_wp |
---|
742 | DO k = buildings(nb)%kb_min, buildings(nb)%kb_max |
---|
743 | buildings(nb)%building_height = buildings(nb)%building_height + dzw(k+1) |
---|
744 | ENDDO |
---|
745 | ENDDO |
---|
746 | ! |
---|
747 | !-- Calculate building volume |
---|
748 | DO nb = 1, num_build |
---|
749 | ! |
---|
750 | !-- Allocate temporary array for summing-up building volume |
---|
751 | ALLOCATE( volume(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
752 | ALLOCATE( volume_l(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
753 | volume = 0.0_wp |
---|
754 | volume_l = 0.0_wp |
---|
755 | ! |
---|
756 | !-- Calculate building volume per height level on each PE where these building is present. |
---|
757 | IF ( buildings(nb)%on_pe ) THEN |
---|
758 | |
---|
759 | ALLOCATE( buildings(nb)%volume(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
760 | ALLOCATE( buildings(nb)%vol_frac(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
761 | buildings(nb)%volume = 0.0_wp |
---|
762 | buildings(nb)%vol_frac = 0.0_wp |
---|
763 | |
---|
764 | IF ( ANY( building_id_f%var(nys:nyn,nxl:nxr) == buildings(nb)%id ) ) THEN |
---|
765 | DO i = nxl, nxr |
---|
766 | DO j = nys, nyn |
---|
767 | DO k = buildings(nb)%kb_min, buildings(nb)%kb_max |
---|
768 | IF ( building_id_f%var(j,i) /= building_id_f%fill ) & |
---|
769 | volume_l(k) = volume_l(k) + dx * dy * dzw(k+1) |
---|
770 | ENDDO |
---|
771 | ENDDO |
---|
772 | ENDDO |
---|
773 | ENDIF |
---|
774 | ENDIF |
---|
775 | ! |
---|
776 | !-- Sum-up building volume from all subdomains |
---|
777 | #if defined( __parallel ) |
---|
778 | CALL MPI_ALLREDUCE( volume_l, volume, SIZE(volume), MPI_REAL, MPI_SUM, comm2d, ierr ) |
---|
779 | #else |
---|
780 | volume = volume_l |
---|
781 | #endif |
---|
782 | ! |
---|
783 | !-- Save total building volume as well as local fraction on volume on building data structure. |
---|
784 | IF ( ALLOCATED( buildings(nb)%volume ) ) buildings(nb)%volume = volume |
---|
785 | ! |
---|
786 | !-- Determine fraction of local on total building volume |
---|
787 | IF ( buildings(nb)%on_pe ) buildings(nb)%vol_frac = volume_l / volume |
---|
788 | ! |
---|
789 | !-- Calculate total building volume |
---|
790 | IF ( ALLOCATED( buildings(nb)%volume ) ) buildings(nb)%vol_tot = SUM( buildings(nb)%volume ) |
---|
791 | |
---|
792 | DEALLOCATE( volume ) |
---|
793 | DEALLOCATE( volume_l ) |
---|
794 | |
---|
795 | ENDDO |
---|
796 | ! |
---|
797 | !-- Allocate arrays for indoor temperature. |
---|
798 | DO nb = 1, num_build |
---|
799 | IF ( buildings(nb)%on_pe ) THEN |
---|
800 | ALLOCATE( buildings(nb)%t_in(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
801 | ALLOCATE( buildings(nb)%t_in_l(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
802 | buildings(nb)%t_in = 0.0_wp |
---|
803 | buildings(nb)%t_in_l = 0.0_wp |
---|
804 | ENDIF |
---|
805 | ENDDO |
---|
806 | ! |
---|
807 | !-- Allocate arrays for number of facades per height level. Distinguish between horizontal and |
---|
808 | !-- vertical facades. |
---|
809 | DO nb = 1, num_build |
---|
810 | IF ( buildings(nb)%on_pe ) THEN |
---|
811 | ALLOCATE( buildings(nb)%num_facade_h(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
812 | ALLOCATE( buildings(nb)%num_facade_v(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
813 | |
---|
814 | buildings(nb)%num_facade_h = 0 |
---|
815 | buildings(nb)%num_facade_v = 0 |
---|
816 | ENDIF |
---|
817 | ENDDO |
---|
818 | ! |
---|
819 | !-- Determine number of facade elements per building on local subdomain. |
---|
820 | !-- Distinguish between horizontal and vertical facade elements. |
---|
821 | ! |
---|
822 | !-- Horizontal facades |
---|
823 | buildings(:)%num_facades_per_building_h_l = 0 |
---|
824 | DO l = 0, 1 |
---|
825 | DO m = 1, surf_usm_h(l)%ns |
---|
826 | ! |
---|
827 | !-- For the current facade element determine corresponding building index. |
---|
828 | !-- First, obtain j,j,k indices of the building. Please note the offset between facade/surface |
---|
829 | !-- element and building location (for horizontal surface elements the horizontal offsets are |
---|
830 | !-- zero). |
---|
831 | i = surf_usm_h(l)%i(m) + surf_usm_h(l)%ioff |
---|
832 | j = surf_usm_h(l)%j(m) + surf_usm_h(l)%joff |
---|
833 | k = surf_usm_h(l)%k(m) + surf_usm_h(l)%koff |
---|
834 | ! |
---|
835 | !-- Determine building index and check whether building is on PE. |
---|
836 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM=1 ) |
---|
837 | |
---|
838 | IF ( buildings(nb)%on_pe ) THEN |
---|
839 | ! |
---|
840 | !-- Count number of facade elements at each height level. |
---|
841 | buildings(nb)%num_facade_h(k) = buildings(nb)%num_facade_h(k) + 1 |
---|
842 | ! |
---|
843 | !-- Moreover, sum up number of local facade elements per building. |
---|
844 | buildings(nb)%num_facades_per_building_h_l = & |
---|
845 | buildings(nb)%num_facades_per_building_h_l + 1 |
---|
846 | ENDIF |
---|
847 | ENDDO |
---|
848 | ENDDO |
---|
849 | ! |
---|
850 | !-- Vertical facades |
---|
851 | buildings(:)%num_facades_per_building_v_l = 0 |
---|
852 | DO l = 0, 3 |
---|
853 | DO m = 1, surf_usm_v(l)%ns |
---|
854 | ! |
---|
855 | !-- For the current facade element determine corresponding building index. |
---|
856 | !-- First, obtain j,j,k indices of the building. Please note the offset between facade/surface |
---|
857 | !-- element and building location (for vertical surface elements the vertical offsets are |
---|
858 | !-- zero). |
---|
859 | i = surf_usm_v(l)%i(m) + surf_usm_v(l)%ioff |
---|
860 | j = surf_usm_v(l)%j(m) + surf_usm_v(l)%joff |
---|
861 | k = surf_usm_v(l)%k(m) + surf_usm_v(l)%koff |
---|
862 | |
---|
863 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM=1 ) |
---|
864 | IF ( buildings(nb)%on_pe ) THEN |
---|
865 | buildings(nb)%num_facade_v(k) = buildings(nb)%num_facade_v(k) + 1 |
---|
866 | buildings(nb)%num_facades_per_building_v_l = & |
---|
867 | buildings(nb)%num_facades_per_building_v_l + 1 |
---|
868 | ENDIF |
---|
869 | ENDDO |
---|
870 | ENDDO |
---|
871 | ! |
---|
872 | !-- Determine total number of facade elements per building and assign number to building data type. |
---|
873 | DO nb = 1, num_build |
---|
874 | ! |
---|
875 | !-- Allocate dummy array used for summing-up facade elements. |
---|
876 | !-- Please note, dummy arguments are necessary as building-date type arrays are not necessarily |
---|
877 | !-- allocated on all PEs. |
---|
878 | ALLOCATE( num_facades_h(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
879 | ALLOCATE( num_facades_v(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
880 | ALLOCATE( receive_dum_h(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
881 | ALLOCATE( receive_dum_v(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
882 | num_facades_h = 0 |
---|
883 | num_facades_v = 0 |
---|
884 | receive_dum_h = 0 |
---|
885 | receive_dum_v = 0 |
---|
886 | |
---|
887 | IF ( buildings(nb)%on_pe ) THEN |
---|
888 | num_facades_h = buildings(nb)%num_facade_h |
---|
889 | num_facades_v = buildings(nb)%num_facade_v |
---|
890 | ENDIF |
---|
891 | |
---|
892 | #if defined( __parallel ) |
---|
893 | CALL MPI_ALLREDUCE( num_facades_h, & |
---|
894 | receive_dum_h, & |
---|
895 | buildings(nb)%kb_max - buildings(nb)%kb_min + 1, & |
---|
896 | MPI_INTEGER, & |
---|
897 | MPI_SUM, & |
---|
898 | comm2d, & |
---|
899 | ierr ) |
---|
900 | |
---|
901 | CALL MPI_ALLREDUCE( num_facades_v, & |
---|
902 | receive_dum_v, & |
---|
903 | buildings(nb)%kb_max - buildings(nb)%kb_min + 1, & |
---|
904 | MPI_INTEGER, & |
---|
905 | MPI_SUM, & |
---|
906 | comm2d, & |
---|
907 | ierr ) |
---|
908 | IF ( ALLOCATED( buildings(nb)%num_facade_h ) ) buildings(nb)%num_facade_h = receive_dum_h |
---|
909 | IF ( ALLOCATED( buildings(nb)%num_facade_v ) ) buildings(nb)%num_facade_v = receive_dum_v |
---|
910 | #else |
---|
911 | buildings(nb)%num_facade_h = num_facades_h |
---|
912 | buildings(nb)%num_facade_v = num_facades_v |
---|
913 | #endif |
---|
914 | |
---|
915 | ! |
---|
916 | !-- Deallocate dummy arrays |
---|
917 | DEALLOCATE( num_facades_h ) |
---|
918 | DEALLOCATE( num_facades_v ) |
---|
919 | DEALLOCATE( receive_dum_h ) |
---|
920 | DEALLOCATE( receive_dum_v ) |
---|
921 | ! |
---|
922 | !-- Allocate index arrays which link facade elements with surface-data type. |
---|
923 | !-- Please note, no height levels are considered here (information is stored in surface-data type |
---|
924 | !-- itself). |
---|
925 | IF ( buildings(nb)%on_pe ) THEN |
---|
926 | ! |
---|
927 | !-- Determine number of facade elements per building. |
---|
928 | buildings(nb)%num_facades_per_building_h = SUM( buildings(nb)%num_facade_h ) |
---|
929 | buildings(nb)%num_facades_per_building_v = SUM( buildings(nb)%num_facade_v ) |
---|
930 | ! |
---|
931 | !-- Allocate arrays which link the building with the horizontal and vertical urban-type |
---|
932 | !-- surfaces. Please note, linking arrays are allocated over all facade elements, which is |
---|
933 | !-- required in case a building is located at the subdomain boundaries, where the building and |
---|
934 | !-- the corresponding surface elements are located on different subdomains. |
---|
935 | ALLOCATE( buildings(nb)%l_h(1:buildings(nb)%num_facades_per_building_h_l) ) |
---|
936 | ALLOCATE( buildings(nb)%m_h(1:buildings(nb)%num_facades_per_building_h_l) ) |
---|
937 | |
---|
938 | ALLOCATE( buildings(nb)%l_v(1:buildings(nb)%num_facades_per_building_v_l) ) |
---|
939 | ALLOCATE( buildings(nb)%m_v(1:buildings(nb)%num_facades_per_building_v_l) ) |
---|
940 | |
---|
941 | ALLOCATE( buildings(nb)%theta_m_t_prev_h(1:buildings(nb)%num_facades_per_building_h_l) ) |
---|
942 | ALLOCATE( buildings(nb)%theta_m_t_prev_v(1:buildings(nb)%num_facades_per_building_v_l) ) |
---|
943 | ENDIF |
---|
944 | |
---|
945 | IF ( buildings(nb)%on_pe ) THEN |
---|
946 | ALLOCATE( buildings(nb)%vpf(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
947 | buildings(nb)%vpf = 0.0_wp |
---|
948 | |
---|
949 | facade_area_v = 0.0_wp |
---|
950 | DO k = buildings(nb)%kb_min, buildings(nb)%kb_max |
---|
951 | facade_area_v = facade_area_v + buildings(nb)%num_facade_v(k) * dzw(k+1) * dx |
---|
952 | ENDDO |
---|
953 | ! |
---|
954 | !-- Determine volume per total facade area (vpf). For the horizontal facade area |
---|
955 | !-- num_facades_per_building_h can be taken, multiplied with dx*dy. |
---|
956 | !-- However, due to grid stretching, vertical facade elements must be summed-up vertically. |
---|
957 | !-- Please note, if dx /= dy, an error is made! |
---|
958 | buildings(nb)%vpf = buildings(nb)%vol_tot / & |
---|
959 | ( buildings(nb)%num_facades_per_building_h * dx * dy + facade_area_v ) |
---|
960 | ! |
---|
961 | !-- Determine floor-area-per-facade. |
---|
962 | buildings(nb)%fapf = buildings(nb)%num_facades_per_building_h * dx * dy & |
---|
963 | / ( buildings(nb)%num_facades_per_building_h * dx * dy & |
---|
964 | + facade_area_v ) |
---|
965 | ENDIF |
---|
966 | ENDDO |
---|
967 | ! |
---|
968 | !-- Link facade elements with surface data type. |
---|
969 | !-- Allocate array for counting. |
---|
970 | ALLOCATE( n_fa(1:num_build) ) |
---|
971 | n_fa = 1 |
---|
972 | |
---|
973 | DO l = 0, 1 |
---|
974 | DO m = 1, surf_usm_h(l)%ns |
---|
975 | i = surf_usm_h(l)%i(m) + surf_usm_h(l)%ioff |
---|
976 | j = surf_usm_h(l)%j(m) + surf_usm_h(l)%joff |
---|
977 | |
---|
978 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM=1 ) |
---|
979 | |
---|
980 | IF ( buildings(nb)%on_pe ) THEN |
---|
981 | buildings(nb)%l_h(n_fa(nb)) = l |
---|
982 | buildings(nb)%m_h(n_fa(nb)) = m |
---|
983 | n_fa(nb) = n_fa(nb) + 1 |
---|
984 | ENDIF |
---|
985 | ENDDO |
---|
986 | ENDDO |
---|
987 | |
---|
988 | n_fa = 1 |
---|
989 | DO l = 0, 3 |
---|
990 | DO m = 1, surf_usm_v(l)%ns |
---|
991 | i = surf_usm_v(l)%i(m) + surf_usm_v(l)%ioff |
---|
992 | j = surf_usm_v(l)%j(m) + surf_usm_v(l)%joff |
---|
993 | |
---|
994 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM=1 ) |
---|
995 | |
---|
996 | IF ( buildings(nb)%on_pe ) THEN |
---|
997 | buildings(nb)%l_v(n_fa(nb)) = l |
---|
998 | buildings(nb)%m_v(n_fa(nb)) = m |
---|
999 | n_fa(nb) = n_fa(nb) + 1 |
---|
1000 | ENDIF |
---|
1001 | ENDDO |
---|
1002 | ENDDO |
---|
1003 | DEALLOCATE( n_fa ) |
---|
1004 | ! |
---|
1005 | !-- Initialize building parameters, first by mean building type. Note, in this case all buildings |
---|
1006 | !-- have the same type. |
---|
1007 | !-- In a second step initialize with building tpyes from static input file, where building types can |
---|
1008 | !-- be individual for each building. |
---|
1009 | buildings(:)%lambda_layer3 = building_pars(31,building_type) |
---|
1010 | buildings(:)%s_layer3 = building_pars(44,building_type) |
---|
1011 | buildings(:)%f_c_win = building_pars(119,building_type) |
---|
1012 | buildings(:)%g_value_win = building_pars(120,building_type) |
---|
1013 | buildings(:)%u_value_win = building_pars(121,building_type) |
---|
1014 | buildings(:)%eta_ve = building_pars(124,building_type) |
---|
1015 | buildings(:)%factor_a = building_pars(125,building_type) |
---|
1016 | buildings(:)%factor_c = building_pars(126,building_type) |
---|
1017 | buildings(:)%lambda_at = building_pars(127,building_type) |
---|
1018 | buildings(:)%theta_int_h_set = building_pars(13,building_type) |
---|
1019 | buildings(:)%theta_int_c_set = building_pars(12,building_type) |
---|
1020 | buildings(:)%q_h_max = building_pars(128,building_type) |
---|
1021 | buildings(:)%q_c_max = building_pars(129,building_type) |
---|
1022 | buildings(:)%qint_high = building_pars(130,building_type) |
---|
1023 | buildings(:)%qint_low = building_pars(131,building_type) |
---|
1024 | buildings(:)%height_storey = building_pars(132,building_type) |
---|
1025 | buildings(:)%height_cei_con = building_pars(133,building_type) |
---|
1026 | buildings(:)%params_waste_heat_h = building_pars(134,building_type) |
---|
1027 | buildings(:)%params_waste_heat_c = building_pars(135,building_type) |
---|
1028 | ! |
---|
1029 | !-- Initialize seasonal dependent parameters, depending on day of the year. |
---|
1030 | !-- First, calculated day of the year. |
---|
1031 | CALL get_date_time( time_since_reference_point, day_of_year = day_of_year ) |
---|
1032 | ! |
---|
1033 | !-- Summer is defined in between northward- and southward equinox. |
---|
1034 | IF ( day_of_year >= northward_equinox .AND. day_of_year <= southward_equinox ) THEN |
---|
1035 | buildings(:)%air_change_low = summer_pars(0,building_type) |
---|
1036 | buildings(:)%air_change_high = summer_pars(1,building_type) |
---|
1037 | ELSE |
---|
1038 | buildings(:)%air_change_low = winter_pars(0,building_type) |
---|
1039 | buildings(:)%air_change_high = winter_pars(1,building_type) |
---|
1040 | ENDIF |
---|
1041 | ! |
---|
1042 | !-- Initialize ventilation load. Please note, building types > 7 are actually not allowed (check |
---|
1043 | !-- already in urban_surface_mod and netcdf_data_input_mod. |
---|
1044 | !-- However, the building data base may be later extended. |
---|
1045 | IF ( building_type == 1 .OR. building_type == 2 .OR. & |
---|
1046 | building_type == 3 .OR. building_type == 10 .OR. & |
---|
1047 | building_type == 11 .OR. building_type == 12 ) THEN |
---|
1048 | buildings(:)%ventilation_int_loads = 1 |
---|
1049 | ! |
---|
1050 | !-- Office, building with large windows |
---|
1051 | ELSEIF ( building_type == 4 .OR. building_type == 5 .OR. & |
---|
1052 | building_type == 6 .OR. building_type == 7 .OR. & |
---|
1053 | building_type == 8 .OR. building_type == 9) THEN |
---|
1054 | buildings(:)%ventilation_int_loads = 2 |
---|
1055 | ! |
---|
1056 | !-- Industry, hospitals |
---|
1057 | ELSEIF ( building_type == 13 .OR. building_type == 14 .OR. & |
---|
1058 | building_type == 15 .OR. building_type == 16 .OR. & |
---|
1059 | building_type == 17 .OR. building_type == 18 ) THEN |
---|
1060 | buildings(:)%ventilation_int_loads = 3 |
---|
1061 | ENDIF |
---|
1062 | ! |
---|
1063 | !-- Initialization of building parameters - level 2 |
---|
1064 | IF ( building_type_f%from_file ) THEN |
---|
1065 | DO i = nxl, nxr |
---|
1066 | DO j = nys, nyn |
---|
1067 | IF ( building_id_f%var(j,i) /= building_id_f%fill ) THEN |
---|
1068 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM=1 ) |
---|
1069 | bt = building_type_f%var(j,i) |
---|
1070 | |
---|
1071 | buildings(nb)%lambda_layer3 = building_pars(31,bt) |
---|
1072 | buildings(nb)%s_layer3 = building_pars(44,bt) |
---|
1073 | buildings(nb)%f_c_win = building_pars(119,bt) |
---|
1074 | buildings(nb)%g_value_win = building_pars(120,bt) |
---|
1075 | buildings(nb)%u_value_win = building_pars(121,bt) |
---|
1076 | buildings(nb)%eta_ve = building_pars(124,bt) |
---|
1077 | buildings(nb)%factor_a = building_pars(125,bt) |
---|
1078 | buildings(nb)%factor_c = building_pars(126,bt) |
---|
1079 | buildings(nb)%lambda_at = building_pars(127,bt) |
---|
1080 | buildings(nb)%theta_int_h_set = building_pars(13,bt) |
---|
1081 | buildings(nb)%theta_int_c_set = building_pars(12,bt) |
---|
1082 | buildings(nb)%q_h_max = building_pars(128,bt) |
---|
1083 | buildings(nb)%q_c_max = building_pars(129,bt) |
---|
1084 | buildings(nb)%qint_high = building_pars(130,bt) |
---|
1085 | buildings(nb)%qint_low = building_pars(131,bt) |
---|
1086 | buildings(nb)%height_storey = building_pars(132,bt) |
---|
1087 | buildings(nb)%height_cei_con = building_pars(133,bt) |
---|
1088 | buildings(nb)%params_waste_heat_h = building_pars(134,bt) |
---|
1089 | buildings(nb)%params_waste_heat_c = building_pars(135,bt) |
---|
1090 | |
---|
1091 | IF ( day_of_year >= northward_equinox .AND. day_of_year <= southward_equinox ) THEN |
---|
1092 | buildings(nb)%air_change_low = summer_pars(0,bt) |
---|
1093 | buildings(nb)%air_change_high = summer_pars(1,bt) |
---|
1094 | ELSE |
---|
1095 | buildings(nb)%air_change_low = winter_pars(0,bt) |
---|
1096 | buildings(nb)%air_change_high = winter_pars(1,bt) |
---|
1097 | ENDIF |
---|
1098 | |
---|
1099 | ! |
---|
1100 | !-- Initialize ventilaation load. Please note, building types > 7 |
---|
1101 | !-- are actually not allowed (check already in urban_surface_mod |
---|
1102 | !-- and netcdf_data_input_mod. However, the building data base may |
---|
1103 | !-- be later extended. |
---|
1104 | IF ( bt == 1 .OR. bt == 2 .OR. & |
---|
1105 | bt == 3 .OR. bt == 10 .OR. & |
---|
1106 | bt == 11 .OR. bt == 12 ) THEN |
---|
1107 | buildings(nb)%ventilation_int_loads = 1 |
---|
1108 | ! |
---|
1109 | !-- Office, building with large windows |
---|
1110 | ELSEIF ( bt == 4 .OR. bt == 5 .OR. & |
---|
1111 | bt == 6 .OR. bt == 7 .OR. & |
---|
1112 | bt == 8 .OR. bt == 9) THEN |
---|
1113 | buildings(nb)%ventilation_int_loads = 2 |
---|
1114 | ! |
---|
1115 | !-- Industry, hospitals |
---|
1116 | ELSEIF ( bt == 13 .OR. bt == 14 .OR. & |
---|
1117 | bt == 15 .OR. bt == 16 .OR. & |
---|
1118 | bt == 17 .OR. bt == 18 ) THEN |
---|
1119 | buildings(nb)%ventilation_int_loads = 3 |
---|
1120 | ENDIF |
---|
1121 | ENDIF |
---|
1122 | ENDDO |
---|
1123 | ENDDO |
---|
1124 | ENDIF |
---|
1125 | ! |
---|
1126 | !-- Calculation of surface-related heat transfer coeffiecient out of standard u-values from building |
---|
1127 | !-- database. |
---|
1128 | !-- Only amount of extern and surface is used. |
---|
1129 | !-- Otherwise amount between air and surface taken account twice. |
---|
1130 | DO nb = 1, num_build |
---|
1131 | IF ( buildings(nb)%on_pe ) THEN |
---|
1132 | du_win_tmp = 1.0_wp / buildings(nb)%u_value_win |
---|
1133 | u_tmp = buildings(nb)%u_value_win * ( du_win_tmp / ( du_win_tmp - & |
---|
1134 | 0.125_wp + ( 1.0_wp / h_is ) ) ) |
---|
1135 | |
---|
1136 | du_tmp = 1.0_wp / u_tmp |
---|
1137 | |
---|
1138 | buildings(nb)%h_es = 1.0_wp / ( du_tmp - ( 1.0_wp / h_is ) ) |
---|
1139 | |
---|
1140 | ENDIF |
---|
1141 | ENDDO |
---|
1142 | ! |
---|
1143 | !-- Initialize indoor temperature. Actually only for output at initial state. |
---|
1144 | DO nb = 1, num_build |
---|
1145 | IF ( buildings(nb)%on_pe ) THEN |
---|
1146 | buildings(nb)%t_in(:) = initial_indoor_temperature |
---|
1147 | |
---|
1148 | ! |
---|
1149 | !-- (after first loop, use theta_m_t as theta_m_t_prev) |
---|
1150 | buildings(nb)%theta_m_t_prev_h(:) = initial_indoor_temperature |
---|
1151 | buildings(nb)%theta_m_t_prev_v(:) = initial_indoor_temperature |
---|
1152 | |
---|
1153 | ENDIF |
---|
1154 | ENDDO |
---|
1155 | |
---|
1156 | CALL location_message( 'initializing indoor model', 'finished' ) |
---|
1157 | |
---|
1158 | END SUBROUTINE im_init |
---|
1159 | |
---|
1160 | |
---|
1161 | !--------------------------------------------------------------------------------------------------! |
---|
1162 | ! Description: |
---|
1163 | ! ------------ |
---|
1164 | !> Main part of the indoor model. |
---|
1165 | !> Calculation of .... (kanani: Please describe) |
---|
1166 | !--------------------------------------------------------------------------------------------------! |
---|
1167 | SUBROUTINE im_main_heatcool |
---|
1168 | |
---|
1169 | ! USE basic_constants_and_equations_mod, & |
---|
1170 | ! ONLY: c_p |
---|
1171 | |
---|
1172 | USE control_parameters, & |
---|
1173 | ONLY: time_since_reference_point |
---|
1174 | |
---|
1175 | USE grid_variables, & |
---|
1176 | ONLY: dx, dy |
---|
1177 | |
---|
1178 | USE pegrid |
---|
1179 | |
---|
1180 | USE surface_mod, & |
---|
1181 | ONLY: ind_veg_wall, ind_wat_win, surf_usm_h, surf_usm_v |
---|
1182 | |
---|
1183 | USE urban_surface_mod, & |
---|
1184 | ONLY: building_type, nzt_wall, t_wall_h, t_wall_v, t_window_h, t_window_v |
---|
1185 | |
---|
1186 | |
---|
1187 | INTEGER(iwp) :: fa !< running index for facade elements of each building |
---|
1188 | INTEGER(iwp) :: i !< index of facade-adjacent atmosphere grid point in x-direction |
---|
1189 | INTEGER(iwp) :: j !< index of facade-adjacent atmosphere grid point in y-direction |
---|
1190 | INTEGER(iwp) :: k !< index of facade-adjacent atmosphere grid point in z-direction |
---|
1191 | INTEGER(iwp) :: kk !< vertical index of indoor grid point adjacent to facade |
---|
1192 | INTEGER(iwp) :: l !< running index for surface-element orientation |
---|
1193 | INTEGER(iwp) :: m !< running index surface elements |
---|
1194 | INTEGER(iwp) :: nb !< running index for buildings |
---|
1195 | |
---|
1196 | REAL(wp) :: indoor_wall_window_temperature !< weighted temperature of innermost wall/window layer |
---|
1197 | REAL(wp) :: near_facade_temperature !< outside air temperature 10cm away from facade |
---|
1198 | REAL(wp) :: second_of_day !< second of the current day |
---|
1199 | REAL(wp) :: time_utc_hour !< time of day (hour UTC) |
---|
1200 | |
---|
1201 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in_l_send !< dummy send buffer used for summing-up indoor temperature per kk-level |
---|
1202 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in_recv !< dummy recv buffer used for summing-up indoor temperature per kk-level |
---|
1203 | ! |
---|
1204 | !-- Determine time of day in hours. |
---|
1205 | CALL get_date_time( time_since_reference_point, second_of_day=second_of_day ) |
---|
1206 | time_utc_hour = second_of_day / seconds_per_hour |
---|
1207 | ! |
---|
1208 | !-- Following calculations must be done for each facade element. |
---|
1209 | DO nb = 1, num_build |
---|
1210 | ! |
---|
1211 | !-- First, check whether building is present on local subdomain. |
---|
1212 | IF ( buildings(nb)%on_pe ) THEN |
---|
1213 | ! |
---|
1214 | !-- Determine daily schedule. 08:00-18:00 = 1, other hours = 0. |
---|
1215 | !-- Residental Building, panel WBS 70 |
---|
1216 | IF ( buildings(nb)%ventilation_int_loads == 1 ) THEN |
---|
1217 | IF ( time_utc_hour >= 8.0_wp .AND. time_utc_hour <= 18.0_wp ) THEN |
---|
1218 | schedule_d = 0 |
---|
1219 | ELSE |
---|
1220 | schedule_d = 1 |
---|
1221 | ENDIF |
---|
1222 | ENDIF |
---|
1223 | ! |
---|
1224 | !-- Office, building with large windows |
---|
1225 | IF ( buildings(nb)%ventilation_int_loads == 2 ) THEN |
---|
1226 | IF ( time_utc_hour >= 8.0_wp .AND. time_utc_hour <= 18.0_wp ) THEN |
---|
1227 | schedule_d = 1 |
---|
1228 | ELSE |
---|
1229 | schedule_d = 0 |
---|
1230 | ENDIF |
---|
1231 | ENDIF |
---|
1232 | ! |
---|
1233 | !-- Industry, hospitals |
---|
1234 | IF ( buildings(nb)%ventilation_int_loads == 3 ) THEN |
---|
1235 | IF ( time_utc_hour >= 6.0_wp .AND. time_utc_hour <= 22.0_wp ) THEN |
---|
1236 | schedule_d = 1 |
---|
1237 | ELSE |
---|
1238 | schedule_d = 0 |
---|
1239 | ENDIF |
---|
1240 | ENDIF |
---|
1241 | ! |
---|
1242 | !-- Initialize/reset indoor temperature |
---|
1243 | buildings(nb)%t_in_l = 0.0_wp |
---|
1244 | ! |
---|
1245 | !-- Horizontal surfaces |
---|
1246 | DO fa = 1, buildings(nb)%num_facades_per_building_h_l |
---|
1247 | ! |
---|
1248 | !-- Determine indices where corresponding surface-type information is stored. |
---|
1249 | l = buildings(nb)%l_h(fa) |
---|
1250 | m = buildings(nb)%m_h(fa) |
---|
1251 | ! |
---|
1252 | !-- Determine building height level index. |
---|
1253 | kk = surf_usm_h(l)%k(m) + surf_usm_h(l)%koff |
---|
1254 | ! |
---|
1255 | !-- Building geometries --> not time-dependent |
---|
1256 | facade_element_area = dx * dy !< [m2] surface area per facade element |
---|
1257 | floor_area_per_facade = buildings(nb)%fapf !< [m2/m2] floor area per facade area |
---|
1258 | indoor_volume_per_facade = buildings(nb)%vpf(kk) !< [m3/m2] indoor air volume per facade area |
---|
1259 | buildings(nb)%area_facade = facade_element_area * & |
---|
1260 | ( buildings(nb)%num_facades_per_building_h + & |
---|
1261 | buildings(nb)%num_facades_per_building_v ) !< [m2] area of total facade |
---|
1262 | window_area_per_facade = surf_usm_h(l)%frac(m,ind_wat_win) * facade_element_area !< [m2] window area per facade |
---|
1263 | !< element |
---|
1264 | |
---|
1265 | buildings(nb)%net_floor_area = buildings(nb)%vol_tot / ( buildings(nb)%height_storey ) |
---|
1266 | total_area = buildings(nb)%net_floor_area !< [m2] area of all surfaces |
---|
1267 | !< pointing to zone Eq. (9) according to section 7.2.2.2 |
---|
1268 | a_m = buildings(nb)%factor_a * total_area * & |
---|
1269 | ( facade_element_area / buildings(nb)%area_facade ) * & |
---|
1270 | buildings(nb)%lambda_at !< [m2] standard values |
---|
1271 | !< according to Table 12 section 12.3.1.2 (calculate over Eq. (65) according to section 12.3.1.2) |
---|
1272 | c_m = buildings(nb)%factor_c * total_area * & |
---|
1273 | ( facade_element_area / buildings(nb)%area_facade ) !< [J/K] standard values |
---|
1274 | !< according to table 12 section 12.3.1.2 (calculate over Eq. (66) according to section 12.3.1.2) |
---|
1275 | ! |
---|
1276 | !-- Calculation of heat transfer coefficient for transmission --> not time-dependent |
---|
1277 | h_t_es = window_area_per_facade * buildings(nb)%h_es !< [W/K] only for windows |
---|
1278 | |
---|
1279 | h_t_is = buildings(nb)%area_facade * h_is !< [W/K] with h_is = 3.45 W / |
---|
1280 | !< (m2 K) between surface and air, Eq. (9) |
---|
1281 | h_t_ms = a_m * h_ms !< [W/K] with h_ms = 9.10 W / |
---|
1282 | !< (m2 K) between component and surface, Eq. (64) |
---|
1283 | h_t_wall = 1.0_wp / ( 1.0_wp / ( ( facade_element_area - window_area_per_facade ) & !< [W/K] |
---|
1284 | * buildings(nb)%lambda_layer3 / buildings(nb)%s_layer3 * 0.5_wp & |
---|
1285 | ) + 1.0_wp / h_t_ms ) !< [W/K] opaque components |
---|
1286 | h_t_wm = 1.0_wp / ( 1.0_wp / h_t_wall - 1.0_wp / h_t_ms ) !< [W/K] emmision Eq. (63), |
---|
1287 | !< Section 12.2.2 |
---|
1288 | ! |
---|
1289 | !-- Internal air loads dependent on the occupacy of the room. |
---|
1290 | !-- Basical internal heat gains (qint_low) with additional internal heat gains by occupancy (qint_high) (0,5*phi_int). |
---|
1291 | phi_ia = 0.5_wp * ( ( buildings(nb)%qint_high * schedule_d + buildings(nb)%qint_low ) & |
---|
1292 | * floor_area_per_facade ) |
---|
1293 | q_int = phi_ia / total_area |
---|
1294 | ! |
---|
1295 | !-- Airflow dependent on the occupacy of the room. |
---|
1296 | !-- Basical airflow (air_change_low) with additional airflow gains by occupancy (air_change_high) |
---|
1297 | air_change = ( buildings(nb)%air_change_high * schedule_d + buildings(nb)%air_change_low ) !< [1/h]? |
---|
1298 | ! |
---|
1299 | !-- Heat transfer of ventilation. |
---|
1300 | !-- Not less than 0.01 W/K to avoid division by 0 in further calculations with heat |
---|
1301 | !-- capacity of air 0.33 Wh/m2K. |
---|
1302 | h_v = MAX( 0.01_wp , ( air_change * indoor_volume_per_facade * & |
---|
1303 | 0.33_wp * (1.0_wp - buildings(nb)%eta_ve ) ) ) !< [W/K] from ISO 13789 Eq.(10) |
---|
1304 | |
---|
1305 | !-- Heat transfer coefficient auxiliary variables |
---|
1306 | h_t_1 = 1.0_wp / ( ( 1.0_wp / h_v ) + ( 1.0_wp / h_t_is ) ) !< [W/K] Eq. (C.6) |
---|
1307 | h_t_2 = h_t_1 + h_t_es !< [W/K] Eq. (C.7) |
---|
1308 | h_t_3 = 1.0_wp / ( ( 1.0_wp / h_t_2 ) + ( 1.0_wp / h_t_ms ) ) !< [W/K] Eq. (C.8) |
---|
1309 | ! |
---|
1310 | !-- Net short-wave radiation through window area (was i_global) |
---|
1311 | net_sw_in = surf_usm_h(l)%rad_sw_in(m) - surf_usm_h(l)%rad_sw_out(m) |
---|
1312 | ! |
---|
1313 | !-- Quantities needed for im_calc_temperatures |
---|
1314 | i = surf_usm_h(l)%i(m) |
---|
1315 | j = surf_usm_h(l)%j(m) |
---|
1316 | k = surf_usm_h(l)%k(m) |
---|
1317 | near_facade_temperature = surf_usm_h(l)%pt_10cm(m) |
---|
1318 | indoor_wall_window_temperature = & |
---|
1319 | surf_usm_h(l)%frac(m,ind_veg_wall) * t_wall_h(l)%val(nzt_wall,m) & |
---|
1320 | + surf_usm_h(l)%frac(m,ind_wat_win) * t_window_h(l)%val(nzt_wall,m) |
---|
1321 | ! |
---|
1322 | !-- Solar thermal gains. If net_sw_in larger than sun-protection threshold parameter |
---|
1323 | !-- (params_solar_protection), sun protection will be activated. |
---|
1324 | IF ( net_sw_in <= params_solar_protection ) THEN |
---|
1325 | solar_protection_off = 1 |
---|
1326 | solar_protection_on = 0 |
---|
1327 | ELSE |
---|
1328 | solar_protection_off = 0 |
---|
1329 | solar_protection_on = 1 |
---|
1330 | ENDIF |
---|
1331 | ! |
---|
1332 | !-- Calculation of total heat gains from net_sw_in through windows [W] in respect on |
---|
1333 | !-- automatic sun protection. |
---|
1334 | !-- DIN 4108 - 2 chap.8 |
---|
1335 | phi_sol = ( window_area_per_facade * net_sw_in * solar_protection_off & |
---|
1336 | + window_area_per_facade * net_sw_in * buildings(nb)%f_c_win * & |
---|
1337 | solar_protection_on ) & |
---|
1338 | * buildings(nb)%g_value_win * ( 1.0_wp - params_f_f ) * params_f_w |
---|
1339 | q_sol = phi_sol |
---|
1340 | ! |
---|
1341 | !-- Calculation of the mass specific thermal load for internal and external heatsources of |
---|
1342 | !-- the inner node. |
---|
1343 | phi_m = (a_m / total_area) * ( phi_ia + phi_sol ) !< [W] Eq. (C.2) with |
---|
1344 | !< phi_ia=0,5*phi_int |
---|
1345 | q_c_m = phi_m |
---|
1346 | ! |
---|
1347 | !-- Calculation mass specific thermal load implied non thermal mass |
---|
1348 | phi_st = ( 1.0_wp - ( a_m / total_area ) - ( h_t_es / ( 9.1_wp * total_area ) ) ) & |
---|
1349 | * ( phi_ia + phi_sol ) !< [W] Eq. (C.3) with |
---|
1350 | !< phi_ia=0,5*phi_int |
---|
1351 | q_c_st = phi_st |
---|
1352 | ! |
---|
1353 | !-- Calculations for deriving indoor temperature and heat flux into the wall |
---|
1354 | !-- Step 1: indoor temperature without heating and cooling |
---|
1355 | !-- section C.4.1 Picture C.2 zone 3) |
---|
1356 | phi_hc_nd = 0.0_wp |
---|
1357 | |
---|
1358 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1359 | near_facade_temperature, phi_hc_nd, buildings(nb)%theta_m_t_prev_h(fa) ) |
---|
1360 | ! |
---|
1361 | !-- If air temperature between border temperatures of heating and cooling, assign output |
---|
1362 | !-- variable, then ready. |
---|
1363 | IF ( buildings(nb)%theta_int_h_set <= theta_air .AND. & |
---|
1364 | theta_air <= buildings(nb)%theta_int_c_set ) THEN |
---|
1365 | phi_hc_nd_ac = 0.0_wp |
---|
1366 | phi_hc_nd = phi_hc_nd_ac |
---|
1367 | theta_air_ac = theta_air |
---|
1368 | ! |
---|
1369 | !-- Step 2: Else, apply 10 W/m2 heating/cooling power and calculate indoor temperature |
---|
1370 | !-- again. |
---|
1371 | ELSE |
---|
1372 | ! |
---|
1373 | !-- Temperature not correct, calculation method according to section C4.2 |
---|
1374 | theta_air_0 = theta_air !< temperature without heating/cooling |
---|
1375 | ! |
---|
1376 | !-- Heating or cooling? |
---|
1377 | IF ( theta_air_0 > buildings(nb)%theta_int_c_set ) THEN |
---|
1378 | theta_air_set = buildings(nb)%theta_int_c_set |
---|
1379 | ELSE |
---|
1380 | theta_air_set = buildings(nb)%theta_int_h_set |
---|
1381 | ENDIF |
---|
1382 | ! |
---|
1383 | !-- Calculate the temperature with phi_hc_nd_10 |
---|
1384 | phi_hc_nd_10 = 10.0_wp * floor_area_per_facade |
---|
1385 | phi_hc_nd = phi_hc_nd_10 |
---|
1386 | |
---|
1387 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1388 | near_facade_temperature, phi_hc_nd, buildings(nb)%theta_m_t_prev_h(fa) ) |
---|
1389 | theta_air_10 = theta_air !< temperature with 10 W/m2 of heating |
---|
1390 | phi_hc_nd_un = phi_hc_nd_10 * (theta_air_set - theta_air_0) & |
---|
1391 | / (theta_air_10 - theta_air_0) !< Eq. (C.13) |
---|
1392 | ! |
---|
1393 | !-- Step 3: with temperature ratio to determine the heating or cooling capacity. |
---|
1394 | !-- If necessary, limit the power to maximum power. |
---|
1395 | !-- section C.4.1 Picture C.2 zone 2) and 4) |
---|
1396 | buildings(nb)%phi_c_max = buildings(nb)%q_c_max * floor_area_per_facade |
---|
1397 | buildings(nb)%phi_h_max = buildings(nb)%q_h_max * floor_area_per_facade |
---|
1398 | IF ( buildings(nb)%phi_c_max < phi_hc_nd_un .AND. & |
---|
1399 | phi_hc_nd_un < buildings(nb)%phi_h_max ) THEN |
---|
1400 | phi_hc_nd_ac = phi_hc_nd_un |
---|
1401 | phi_hc_nd = phi_hc_nd_un |
---|
1402 | ELSE |
---|
1403 | ! |
---|
1404 | !-- Step 4: inner temperature with maximum heating (phi_hc_nd_un positive) or cooling |
---|
1405 | !-- (phi_hc_nd_un negative) |
---|
1406 | !-- section C.4.1 Picture C.2 zone 1) and 5) |
---|
1407 | IF ( phi_hc_nd_un > 0.0_wp ) THEN |
---|
1408 | phi_hc_nd_ac = buildings(nb)%phi_h_max !< Limit heating |
---|
1409 | ELSE |
---|
1410 | phi_hc_nd_ac = buildings(nb)%phi_c_max !< Limit cooling |
---|
1411 | ENDIF |
---|
1412 | ENDIF |
---|
1413 | phi_hc_nd = phi_hc_nd_ac |
---|
1414 | ! |
---|
1415 | !-- Calculate the temperature with phi_hc_nd_ac (new) |
---|
1416 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1417 | near_facade_temperature, phi_hc_nd, buildings(nb)%theta_m_t_prev_h(fa) ) |
---|
1418 | theta_air_ac = theta_air |
---|
1419 | ENDIF |
---|
1420 | ! |
---|
1421 | !-- Update theta_m_t_prev |
---|
1422 | buildings(nb)%theta_m_t_prev_h(fa) = theta_m_t |
---|
1423 | |
---|
1424 | |
---|
1425 | q_vent = h_v * ( theta_air - near_facade_temperature ) |
---|
1426 | ! |
---|
1427 | !-- Calculate the operating temperature with weighted mean temperature of air and mean |
---|
1428 | !-- solar temperature. |
---|
1429 | !-- Will be used for thermal comfort calculations. |
---|
1430 | theta_op = 0.3_wp * theta_air_ac + 0.7_wp * theta_s !< [degree_C] operative Temperature Eq. (C.12) |
---|
1431 | |
---|
1432 | ! surf_usm_h(l)%t_indoor(m) = theta_op !< not integrated now |
---|
1433 | ! |
---|
1434 | !-- Heat flux into the wall. Value needed in urban_surface_mod to |
---|
1435 | !-- calculate heat transfer through wall layers towards the facade |
---|
1436 | !-- (use c_p * rho_surface to convert [W/m2] into [K m/s]) |
---|
1437 | q_wall_win = h_t_ms * ( theta_s - theta_m ) & |
---|
1438 | / ( facade_element_area - window_area_per_facade ) |
---|
1439 | q_trans = q_wall_win * facade_element_area |
---|
1440 | ! |
---|
1441 | !-- Transfer q_wall_win back to USM (innermost wall/window layer) |
---|
1442 | surf_usm_h(l)%iwghf_eb(m) = q_wall_win |
---|
1443 | surf_usm_h(l)%iwghf_eb_window(m) = q_wall_win |
---|
1444 | ! |
---|
1445 | !-- Sum up operational indoor temperature per kk-level. Further below, this temperature is |
---|
1446 | !-- reduced by MPI to one temperature per kk-level and building (processor overlapping). |
---|
1447 | buildings(nb)%t_in_l(kk) = buildings(nb)%t_in_l(kk) + theta_op |
---|
1448 | ! |
---|
1449 | !-- Calculation of waste heat. |
---|
1450 | !-- Anthropogenic heat output. |
---|
1451 | IF ( phi_hc_nd_ac > 0.0_wp ) THEN |
---|
1452 | heating_on = 1 |
---|
1453 | cooling_on = 0 |
---|
1454 | ELSE |
---|
1455 | heating_on = 0 |
---|
1456 | cooling_on = -1 |
---|
1457 | ENDIF |
---|
1458 | |
---|
1459 | q_waste_heat = ( phi_hc_nd * ( & |
---|
1460 | buildings(nb)%params_waste_heat_h * heating_on + & |
---|
1461 | buildings(nb)%params_waste_heat_c * cooling_on ) & |
---|
1462 | ) / facade_element_area !< [W/m2] , observe the directional |
---|
1463 | !< convention in PALM! |
---|
1464 | surf_usm_h(l)%waste_heat(m) = 0.0_wp !q_waste_heat |
---|
1465 | ENDDO !< Horizontal surfaces loop |
---|
1466 | ! |
---|
1467 | !-- Vertical surfaces |
---|
1468 | DO fa = 1, buildings(nb)%num_facades_per_building_v_l |
---|
1469 | ! |
---|
1470 | !-- Determine indices where corresponding surface-type information is stored. |
---|
1471 | l = buildings(nb)%l_v(fa) |
---|
1472 | m = buildings(nb)%m_v(fa) |
---|
1473 | ! |
---|
1474 | !-- Determine building height level index. |
---|
1475 | kk = surf_usm_v(l)%k(m) + surf_usm_v(l)%koff |
---|
1476 | ! |
---|
1477 | !-- (SOME OF THE FOLLOWING (not time-dependent) COULD PROBABLY GO INTO A FUNCTION |
---|
1478 | !-- EXCEPT facade_element_area, EVERYTHING IS CALCULATED EQUALLY) |
---|
1479 | !-- Building geometries --> not time-dependent |
---|
1480 | IF ( l == 0 .OR. l == 1 ) facade_element_area = dx * dzw(kk+1) !< [m2] surface area per facade element |
---|
1481 | IF ( l == 2 .OR. l == 3 ) facade_element_area = dy * dzw(kk+1) !< [m2] surface area per facade element |
---|
1482 | |
---|
1483 | floor_area_per_facade = buildings(nb)%fapf !< [m2/m2] floor area per facade area |
---|
1484 | indoor_volume_per_facade = buildings(nb)%vpf(kk) !< [m3/m2] indoor air volume per facade area |
---|
1485 | buildings(nb)%area_facade = facade_element_area * & |
---|
1486 | ( buildings(nb)%num_facades_per_building_h + & |
---|
1487 | buildings(nb)%num_facades_per_building_v ) !< [m2] area of total facade |
---|
1488 | window_area_per_facade = surf_usm_v(l)%frac(m,ind_wat_win) * facade_element_area !< [m2] window area per |
---|
1489 | !< facade element |
---|
1490 | |
---|
1491 | buildings(nb)%net_floor_area = buildings(nb)%vol_tot / ( buildings(nb)%height_storey ) |
---|
1492 | total_area = buildings(nb)%net_floor_area !< [m2] area of all surfaces |
---|
1493 | !< pointing to zone Eq. (9) according to section 7.2.2.2 |
---|
1494 | a_m = buildings(nb)%factor_a * total_area * & |
---|
1495 | ( facade_element_area / buildings(nb)%area_facade ) * & |
---|
1496 | buildings(nb)%lambda_at !< [m2] standard values |
---|
1497 | !< according to Table 12 section 12.3.1.2 (calculate over Eq. (65) according to section 12.3.1.2) |
---|
1498 | c_m = buildings(nb)%factor_c * total_area * & |
---|
1499 | ( facade_element_area / buildings(nb)%area_facade ) !< [J/K] standard values |
---|
1500 | !< according to table 12 section 12.3.1.2 (calculate over Eq. (66) according to section 12.3.1.2) |
---|
1501 | ! |
---|
1502 | !-- Calculation of heat transfer coefficient for transmission --> not time-dependent |
---|
1503 | h_t_es = window_area_per_facade * buildings(nb)%h_es !< [W/K] only for windows |
---|
1504 | |
---|
1505 | h_t_is = buildings(nb)%area_facade * h_is !< [W/K] with h_is = 3.45 W / |
---|
1506 | !< (m2 K) between surface and air, Eq. (9) |
---|
1507 | h_t_ms = a_m * h_ms !< [W/K] with h_ms = 9.10 W / |
---|
1508 | !< (m2 K) between component and surface, Eq. (64) |
---|
1509 | h_t_wall = 1.0_wp / ( 1.0_wp / ( ( facade_element_area - window_area_per_facade ) & !< [W/K] |
---|
1510 | * buildings(nb)%lambda_layer3 / buildings(nb)%s_layer3 * 0.5_wp & |
---|
1511 | ) + 1.0_wp / h_t_ms ) !< [W/K] opaque components |
---|
1512 | h_t_wm = 1.0_wp / ( 1.0_wp / h_t_wall - 1.0_wp / h_t_ms ) !< [W/K] emmision Eq. (63), Section 12.2.2 |
---|
1513 | ! |
---|
1514 | !-- Internal air loads dependent on the occupacy of the room. |
---|
1515 | !-- Basical internal heat gains (qint_low) with additional internal heat gains by occupancy |
---|
1516 | !-- (qint_high) (0,5*phi_int) |
---|
1517 | phi_ia = 0.5_wp * ( ( buildings(nb)%qint_high * schedule_d + buildings(nb)%qint_low ) & |
---|
1518 | * floor_area_per_facade ) |
---|
1519 | q_int = phi_ia |
---|
1520 | |
---|
1521 | ! |
---|
1522 | !-- Airflow dependent on the occupacy of the room. |
---|
1523 | !-- Basical airflow (air_change_low) with additional airflow gains by occupancy |
---|
1524 | !-- (air_change_high) |
---|
1525 | air_change = ( buildings(nb)%air_change_high * schedule_d + & |
---|
1526 | buildings(nb)%air_change_low ) |
---|
1527 | ! |
---|
1528 | !-- Heat transfer of ventilation. |
---|
1529 | !-- Not less than 0.01 W/K to avoid division by 0 in further calculations with heat |
---|
1530 | !-- capacity of air 0.33 Wh/m2K |
---|
1531 | h_v = MAX( 0.01_wp , ( air_change * indoor_volume_per_facade * & |
---|
1532 | 0.33_wp * (1.0_wp - buildings(nb)%eta_ve ) ) ) !< [W/K] from ISO 13789 |
---|
1533 | !< Eq.(10) |
---|
1534 | |
---|
1535 | !-- Heat transfer coefficient auxiliary variables |
---|
1536 | h_t_1 = 1.0_wp / ( ( 1.0_wp / h_v ) + ( 1.0_wp / h_t_is ) ) !< [W/K] Eq. (C.6) |
---|
1537 | h_t_2 = h_t_1 + h_t_es !< [W/K] Eq. (C.7) |
---|
1538 | h_t_3 = 1.0_wp / ( ( 1.0_wp / h_t_2 ) + ( 1.0_wp / h_t_ms ) ) !< [W/K] Eq. (C.8) |
---|
1539 | ! |
---|
1540 | !-- Net short-wave radiation through window area (was i_global) |
---|
1541 | net_sw_in = surf_usm_v(l)%rad_sw_in(m) - surf_usm_v(l)%rad_sw_out(m) |
---|
1542 | ! |
---|
1543 | !-- Quantities needed for im_calc_temperatures |
---|
1544 | i = surf_usm_v(l)%i(m) |
---|
1545 | j = surf_usm_v(l)%j(m) |
---|
1546 | k = surf_usm_v(l)%k(m) |
---|
1547 | near_facade_temperature = surf_usm_v(l)%pt_10cm(m) |
---|
1548 | indoor_wall_window_temperature = & |
---|
1549 | surf_usm_v(l)%frac(m,ind_veg_wall) * t_wall_v(l)%val(nzt_wall,m) & |
---|
1550 | + surf_usm_v(l)%frac(m,ind_wat_win) * t_window_v(l)%val(nzt_wall,m) |
---|
1551 | |
---|
1552 | ! |
---|
1553 | !-- Solar thermal gains. If net_sw_in larger than sun-protection |
---|
1554 | !-- threshold parameter (params_solar_protection), sun protection will |
---|
1555 | !-- be activated |
---|
1556 | IF ( net_sw_in <= params_solar_protection ) THEN |
---|
1557 | solar_protection_off = 1 |
---|
1558 | solar_protection_on = 0 |
---|
1559 | ELSE |
---|
1560 | solar_protection_off = 0 |
---|
1561 | solar_protection_on = 1 |
---|
1562 | ENDIF |
---|
1563 | ! |
---|
1564 | !-- Calculation of total heat gains from net_sw_in through windows [W] in respect on |
---|
1565 | !-- automatic sun protection. |
---|
1566 | !-- DIN 4108 - 2 chap.8 |
---|
1567 | phi_sol = ( window_area_per_facade * net_sw_in * solar_protection_off & |
---|
1568 | + window_area_per_facade * net_sw_in * buildings(nb)%f_c_win * & |
---|
1569 | solar_protection_on ) & |
---|
1570 | * buildings(nb)%g_value_win * ( 1.0_wp - params_f_f ) * params_f_w |
---|
1571 | q_sol = phi_sol |
---|
1572 | ! |
---|
1573 | !-- Calculation of the mass specific thermal load for internal and external heatsources. |
---|
1574 | phi_m = (a_m / total_area) * ( phi_ia + phi_sol ) !< [W] Eq. (C.2) with phi_ia=0,5*phi_int |
---|
1575 | q_c_m = phi_m |
---|
1576 | ! |
---|
1577 | !-- Calculation mass specific thermal load implied non thermal mass. |
---|
1578 | phi_st = ( 1.0_wp - ( a_m / total_area ) - ( h_t_es / ( 9.1_wp * total_area ) ) ) & |
---|
1579 | * ( phi_ia + phi_sol ) !< [W] Eq. (C.3) with |
---|
1580 | !< phi_ia=0,5*phi_int |
---|
1581 | q_c_st = phi_st |
---|
1582 | ! |
---|
1583 | !-- Calculations for deriving indoor temperature and heat flux into the wall. |
---|
1584 | !-- Step 1: indoor temperature without heating and cooling. |
---|
1585 | !-- section C.4.1 Picture C.2 zone 3) |
---|
1586 | phi_hc_nd = 0.0_wp |
---|
1587 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1588 | near_facade_temperature, phi_hc_nd, buildings(nb)%theta_m_t_prev_v(fa) ) |
---|
1589 | ! |
---|
1590 | !-- If air temperature between border temperatures of heating and cooling, assign output |
---|
1591 | !-- variable, then ready. |
---|
1592 | IF ( buildings(nb)%theta_int_h_set <= theta_air .AND. & |
---|
1593 | theta_air <= buildings(nb)%theta_int_c_set ) THEN |
---|
1594 | phi_hc_nd_ac = 0.0_wp |
---|
1595 | phi_hc_nd = phi_hc_nd_ac |
---|
1596 | theta_air_ac = theta_air |
---|
1597 | ! |
---|
1598 | !-- Step 2: Else, apply 10 W/m2 heating/cooling power and calculate indoor temperature |
---|
1599 | !-- again. |
---|
1600 | ELSE |
---|
1601 | ! |
---|
1602 | !-- Temperature not correct, calculation method according to section C4.2 |
---|
1603 | theta_air_0 = theta_air !< Note temperature without heating/cooling |
---|
1604 | ! |
---|
1605 | !-- Heating or cooling? |
---|
1606 | IF ( theta_air_0 > buildings(nb)%theta_int_c_set ) THEN |
---|
1607 | theta_air_set = buildings(nb)%theta_int_c_set |
---|
1608 | ELSE |
---|
1609 | theta_air_set = buildings(nb)%theta_int_h_set |
---|
1610 | ENDIF |
---|
1611 | |
---|
1612 | !-- Calculate the temperature with phi_hc_nd_10 |
---|
1613 | phi_hc_nd_10 = 10.0_wp * floor_area_per_facade |
---|
1614 | phi_hc_nd = phi_hc_nd_10 |
---|
1615 | |
---|
1616 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1617 | near_facade_temperature, phi_hc_nd, buildings(nb)%theta_m_t_prev_v(fa) ) |
---|
1618 | |
---|
1619 | theta_air_10 = theta_air !< Note the temperature with 10 W/m2 of heating |
---|
1620 | |
---|
1621 | phi_hc_nd_un = phi_hc_nd_10 * ( theta_air_set - theta_air_0 ) & |
---|
1622 | / ( theta_air_10 - theta_air_0 ) !< Eq. (C.13) |
---|
1623 | ! |
---|
1624 | !-- Step 3: with temperature ratio to determine the heating or cooling capacity |
---|
1625 | !-- If necessary, limit the power to maximum power. |
---|
1626 | !-- section C.4.1 Picture C.2 zone 2) and 4) |
---|
1627 | buildings(nb)%phi_c_max = buildings(nb)%q_c_max * floor_area_per_facade |
---|
1628 | buildings(nb)%phi_h_max = buildings(nb)%q_h_max * floor_area_per_facade |
---|
1629 | IF ( buildings(nb)%phi_c_max < phi_hc_nd_un .AND. & |
---|
1630 | phi_hc_nd_un < buildings(nb)%phi_h_max ) THEN |
---|
1631 | phi_hc_nd_ac = phi_hc_nd_un |
---|
1632 | phi_hc_nd = phi_hc_nd_un |
---|
1633 | ELSE |
---|
1634 | ! |
---|
1635 | !-- Step 4: inner temperature with maximum heating (phi_hc_nd_un positive) or cooling |
---|
1636 | !-- (phi_hc_nd_un negative) |
---|
1637 | !-- section C.4.1 Picture C.2 zone 1) and 5) |
---|
1638 | IF ( phi_hc_nd_un > 0.0_wp ) THEN |
---|
1639 | phi_hc_nd_ac = buildings(nb)%phi_h_max !< Limit heating |
---|
1640 | ELSE |
---|
1641 | phi_hc_nd_ac = buildings(nb)%phi_c_max !< Limit cooling |
---|
1642 | ENDIF |
---|
1643 | ENDIF |
---|
1644 | phi_hc_nd = phi_hc_nd_ac |
---|
1645 | ! |
---|
1646 | !-- Calculate the temperature with phi_hc_nd_ac (new) |
---|
1647 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1648 | near_facade_temperature, phi_hc_nd, buildings(nb)%theta_m_t_prev_v(fa) ) |
---|
1649 | theta_air_ac = theta_air |
---|
1650 | ENDIF |
---|
1651 | ! |
---|
1652 | !-- Update theta_m_t_prev |
---|
1653 | buildings(nb)%theta_m_t_prev_v(fa) = theta_m_t |
---|
1654 | |
---|
1655 | |
---|
1656 | q_vent = h_v * ( theta_air - near_facade_temperature ) |
---|
1657 | ! |
---|
1658 | !-- Calculate the operating temperature with weighted mean of temperature of air and mean. |
---|
1659 | !-- Will be used for thermal comfort calculations. |
---|
1660 | theta_op = 0.3_wp * theta_air_ac + 0.7_wp * theta_s |
---|
1661 | |
---|
1662 | ! surf_usm_v(l)%t_indoor(m) = theta_op !< not integrated yet |
---|
1663 | ! |
---|
1664 | !-- Heat flux into the wall. Value needed in urban_surface_mod to |
---|
1665 | !-- calculate heat transfer through wall layers towards the facade |
---|
1666 | q_wall_win = h_t_ms * ( theta_s - theta_m ) & |
---|
1667 | / ( facade_element_area - window_area_per_facade ) |
---|
1668 | q_trans = q_wall_win * facade_element_area |
---|
1669 | ! |
---|
1670 | !-- Transfer q_wall_win back to USM (innermost wall/window layer) |
---|
1671 | surf_usm_v(l)%iwghf_eb(m) = q_wall_win |
---|
1672 | surf_usm_v(l)%iwghf_eb_window(m) = q_wall_win |
---|
1673 | ! |
---|
1674 | !-- Sum up operational indoor temperature per kk-level. Further below, this temperature is |
---|
1675 | !-- reduced by MPI to one temperature per kk-level and building (processor overlapping). |
---|
1676 | buildings(nb)%t_in_l(kk) = buildings(nb)%t_in_l(kk) + theta_op |
---|
1677 | ! |
---|
1678 | !-- Calculation of waste heat. |
---|
1679 | !-- Anthropogenic heat output. |
---|
1680 | IF ( phi_hc_nd_ac > 0.0_wp ) THEN |
---|
1681 | heating_on = 1 |
---|
1682 | cooling_on = 0 |
---|
1683 | ELSE |
---|
1684 | heating_on = 0 |
---|
1685 | cooling_on = -1 |
---|
1686 | ENDIF |
---|
1687 | |
---|
1688 | q_waste_heat = ( phi_hc_nd * ( buildings(nb)%params_waste_heat_h * heating_on + & |
---|
1689 | buildings(nb)%params_waste_heat_c * cooling_on ) & |
---|
1690 | ) / facade_element_area !< [W/m2] , observe the directional convention in |
---|
1691 | !< PALM! |
---|
1692 | surf_usm_v(l)%waste_heat(m) = 0.0_wp !q_waste_heat |
---|
1693 | ENDDO !< Vertical surfaces loop |
---|
1694 | ENDIF !< buildings(nb)%on_pe |
---|
1695 | ENDDO !< buildings loop |
---|
1696 | |
---|
1697 | ! |
---|
1698 | !-- Determine the mean building temperature. |
---|
1699 | DO nb = 1, num_build |
---|
1700 | ! |
---|
1701 | !-- Allocate dummy array used for summing-up facade elements. |
---|
1702 | !-- Please note, dummy arguments are necessary as building-date type arrays are not necessarily |
---|
1703 | !-- allocated on all PEs. |
---|
1704 | ALLOCATE( t_in_l_send(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
1705 | ALLOCATE( t_in_recv(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
1706 | t_in_l_send = 0.0_wp |
---|
1707 | t_in_recv = 0.0_wp |
---|
1708 | |
---|
1709 | IF ( buildings(nb)%on_pe ) THEN |
---|
1710 | t_in_l_send = buildings(nb)%t_in_l |
---|
1711 | ENDIF |
---|
1712 | |
---|
1713 | |
---|
1714 | #if defined( __parallel ) |
---|
1715 | CALL MPI_ALLREDUCE( t_in_l_send, & |
---|
1716 | t_in_recv, & |
---|
1717 | buildings(nb)%kb_max - buildings(nb)%kb_min + 1, & |
---|
1718 | MPI_REAL, & |
---|
1719 | MPI_SUM, & |
---|
1720 | comm2d, & |
---|
1721 | ierr ) |
---|
1722 | |
---|
1723 | IF ( ALLOCATED( buildings(nb)%t_in ) ) buildings(nb)%t_in = t_in_recv |
---|
1724 | #else |
---|
1725 | IF ( ALLOCATED( buildings(nb)%t_in ) ) buildings(nb)%t_in = buildings(nb)%t_in_l |
---|
1726 | #endif |
---|
1727 | |
---|
1728 | IF ( ALLOCATED( buildings(nb)%t_in ) ) THEN |
---|
1729 | ! |
---|
1730 | !-- Average indoor temperature. Note, in case a building is completely surrounded by higher |
---|
1731 | !-- buildings, it may have no facade elements at some height levels, which will lead to a |
---|
1732 | !-- division by zero. |
---|
1733 | DO k = buildings(nb)%kb_min, buildings(nb)%kb_max |
---|
1734 | IF ( buildings(nb)%num_facade_h(k) + buildings(nb)%num_facade_v(k) > 0 ) THEN |
---|
1735 | buildings(nb)%t_in(k) = buildings(nb)%t_in(k) / & |
---|
1736 | REAL( buildings(nb)%num_facade_h(k) + & |
---|
1737 | buildings(nb)%num_facade_v(k), KIND = wp ) |
---|
1738 | ENDIF |
---|
1739 | ENDDO |
---|
1740 | ! |
---|
1741 | !-- If indoor temperature is not defined because of missing facade elements, the values from |
---|
1742 | !-- the above-lying level will be taken. |
---|
1743 | !-- At least at the top of the buildings facades are defined, so that at least there an indoor |
---|
1744 | !-- temperature is defined. This information will propagate downwards the building. |
---|
1745 | DO k = buildings(nb)%kb_max-1, buildings(nb)%kb_min, -1 |
---|
1746 | IF ( buildings(nb)%num_facade_h(k) + buildings(nb)%num_facade_v(k) <= 0 ) THEN |
---|
1747 | buildings(nb)%t_in(k) = buildings(nb)%t_in(k+1) |
---|
1748 | ENDIF |
---|
1749 | ENDDO |
---|
1750 | ENDIF |
---|
1751 | |
---|
1752 | |
---|
1753 | ! |
---|
1754 | !-- Deallocate dummy arrays |
---|
1755 | DEALLOCATE( t_in_l_send ) |
---|
1756 | DEALLOCATE( t_in_recv ) |
---|
1757 | |
---|
1758 | ENDDO |
---|
1759 | |
---|
1760 | END SUBROUTINE im_main_heatcool |
---|
1761 | |
---|
1762 | |
---|
1763 | !--------------------------------------------------------------------------------------------------! |
---|
1764 | ! Description: |
---|
1765 | !------------- |
---|
1766 | !> Check data output for plant canopy model |
---|
1767 | !--------------------------------------------------------------------------------------------------! |
---|
1768 | SUBROUTINE im_check_data_output( var, unit ) |
---|
1769 | |
---|
1770 | CHARACTER (LEN=*) :: unit !< |
---|
1771 | CHARACTER (LEN=*) :: var !< |
---|
1772 | |
---|
1773 | SELECT CASE ( TRIM( var ) ) |
---|
1774 | |
---|
1775 | |
---|
1776 | CASE ( 'im_hf_roof') |
---|
1777 | unit = 'W m-2' |
---|
1778 | |
---|
1779 | CASE ( 'im_hf_wall_win' ) |
---|
1780 | unit = 'W m-2' |
---|
1781 | |
---|
1782 | CASE ( 'im_hf_wall_win_waste' ) |
---|
1783 | unit = 'W m-2' |
---|
1784 | |
---|
1785 | CASE ( 'im_hf_roof_waste' ) |
---|
1786 | unit = 'W m-2' |
---|
1787 | |
---|
1788 | CASE ( 'im_t_indoor_mean' ) |
---|
1789 | unit = 'K' |
---|
1790 | |
---|
1791 | CASE ( 'im_t_indoor_roof' ) |
---|
1792 | unit = 'K' |
---|
1793 | |
---|
1794 | CASE ( 'im_t_indoor_wall_win' ) |
---|
1795 | unit = 'K' |
---|
1796 | |
---|
1797 | CASE DEFAULT |
---|
1798 | unit = 'illegal' |
---|
1799 | |
---|
1800 | END SELECT |
---|
1801 | |
---|
1802 | END SUBROUTINE |
---|
1803 | |
---|
1804 | |
---|
1805 | !--------------------------------------------------------------------------------------------------! |
---|
1806 | ! Description: |
---|
1807 | !------------- |
---|
1808 | !> Check parameters routine for plant canopy model |
---|
1809 | !--------------------------------------------------------------------------------------------------! |
---|
1810 | SUBROUTINE im_check_parameters |
---|
1811 | |
---|
1812 | ! USE control_parameters, |
---|
1813 | ! ONLY: message_string |
---|
1814 | |
---|
1815 | END SUBROUTINE im_check_parameters |
---|
1816 | |
---|
1817 | |
---|
1818 | !--------------------------------------------------------------------------------------------------! |
---|
1819 | ! Description: |
---|
1820 | !------------- |
---|
1821 | !> Subroutine defining appropriate grid for netcdf variables. |
---|
1822 | !> It is called from subroutine netcdf. |
---|
1823 | !--------------------------------------------------------------------------------------------------! |
---|
1824 | SUBROUTINE im_define_netcdf_grid( var, found, grid_x, grid_y, grid_z ) |
---|
1825 | |
---|
1826 | CHARACTER (LEN=*), INTENT(OUT) :: grid_x |
---|
1827 | CHARACTER (LEN=*), INTENT(OUT) :: grid_y |
---|
1828 | CHARACTER (LEN=*), INTENT(OUT) :: grid_z |
---|
1829 | CHARACTER (LEN=*), INTENT(IN) :: var |
---|
1830 | |
---|
1831 | LOGICAL, INTENT(OUT) :: found |
---|
1832 | |
---|
1833 | |
---|
1834 | found = .TRUE. |
---|
1835 | ! |
---|
1836 | !-- Check for the grid |
---|
1837 | SELECT CASE ( TRIM( var ) ) |
---|
1838 | |
---|
1839 | CASE ( 'im_hf_roof', 'im_hf_roof_waste' ) |
---|
1840 | grid_x = 'x' |
---|
1841 | grid_y = 'y' |
---|
1842 | grid_z = 'zw' |
---|
1843 | ! |
---|
1844 | !-- Heat fluxes at vertical walls are actually defined on stagged grid, i.e. xu, yv. |
---|
1845 | CASE ( 'im_hf_wall_win', 'im_hf_wall_win_waste' ) |
---|
1846 | grid_x = 'x' |
---|
1847 | grid_y = 'y' |
---|
1848 | grid_z = 'zu' |
---|
1849 | |
---|
1850 | CASE ( 'im_t_indoor_mean', 'im_t_indoor_roof', 'im_t_indoor_wall_win') |
---|
1851 | grid_x = 'x' |
---|
1852 | grid_y = 'y' |
---|
1853 | grid_z = 'zw' |
---|
1854 | |
---|
1855 | CASE DEFAULT |
---|
1856 | found = .FALSE. |
---|
1857 | grid_x = 'none' |
---|
1858 | grid_y = 'none' |
---|
1859 | grid_z = 'none' |
---|
1860 | END SELECT |
---|
1861 | |
---|
1862 | END SUBROUTINE im_define_netcdf_grid |
---|
1863 | |
---|
1864 | |
---|
1865 | !--------------------------------------------------------------------------------------------------! |
---|
1866 | ! Description: |
---|
1867 | ! ------------ |
---|
1868 | !> Subroutine defining 3D output variables |
---|
1869 | !--------------------------------------------------------------------------------------------------! |
---|
1870 | SUBROUTINE im_data_output_3d( av, variable, found, local_pf, fill_value, nzb_do, nzt_do ) |
---|
1871 | |
---|
1872 | USE indices |
---|
1873 | |
---|
1874 | USE kinds |
---|
1875 | |
---|
1876 | CHARACTER (LEN=*) :: variable !< |
---|
1877 | |
---|
1878 | INTEGER(iwp) :: av !< |
---|
1879 | INTEGER(iwp) :: i !< |
---|
1880 | INTEGER(iwp) :: j !< |
---|
1881 | INTEGER(iwp) :: k !< |
---|
1882 | INTEGER(iwp) :: l !< |
---|
1883 | INTEGER(iwp) :: m !< |
---|
1884 | INTEGER(iwp) :: nb !< index of the building in the building data structure |
---|
1885 | INTEGER(iwp) :: nzb_do !< lower limit of the data output (usually 0) |
---|
1886 | INTEGER(iwp) :: nzt_do !< vertical upper limit of the data output (usually nz_do3d) |
---|
1887 | |
---|
1888 | LOGICAL :: found !< |
---|
1889 | |
---|
1890 | REAL(wp), INTENT(IN) :: fill_value !< value for the _FillValue attribute |
---|
1891 | |
---|
1892 | REAL(sp), DIMENSION(nxl:nxr,nys:nyn,nzb_do:nzt_do) :: local_pf !< |
---|
1893 | |
---|
1894 | local_pf = fill_value |
---|
1895 | |
---|
1896 | found = .TRUE. |
---|
1897 | |
---|
1898 | SELECT CASE ( TRIM( variable ) ) |
---|
1899 | ! |
---|
1900 | !-- Output of indoor temperature. All grid points within the building are filled with values, |
---|
1901 | !-- while atmospheric grid points are set to _FillValues. |
---|
1902 | CASE ( 'im_t_indoor_mean' ) |
---|
1903 | IF ( av == 0 ) THEN |
---|
1904 | DO i = nxl, nxr |
---|
1905 | DO j = nys, nyn |
---|
1906 | IF ( building_id_f%var(j,i) /= building_id_f%fill ) THEN |
---|
1907 | ! |
---|
1908 | !-- Determine index of the building within the building data structure. |
---|
1909 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM=1 ) |
---|
1910 | IF ( buildings(nb)%on_pe ) THEN |
---|
1911 | ! |
---|
1912 | !-- Write mean building temperature onto output array. Please note, in |
---|
1913 | !-- contrast to many other loops in the output, the vertical bounds are |
---|
1914 | !-- determined by the lowest and hightest vertical index occupied by the |
---|
1915 | !-- building. |
---|
1916 | DO k = buildings(nb)%kb_min, buildings(nb)%kb_max |
---|
1917 | local_pf(i,j,k) = buildings(nb)%t_in(k) |
---|
1918 | ENDDO |
---|
1919 | ENDIF |
---|
1920 | ENDIF |
---|
1921 | ENDDO |
---|
1922 | ENDDO |
---|
1923 | ENDIF |
---|
1924 | |
---|
1925 | CASE ( 'im_hf_roof' ) |
---|
1926 | IF ( av == 0 ) THEN |
---|
1927 | DO m = 1, surf_usm_h(0)%ns |
---|
1928 | i = surf_usm_h(0)%i(m) !+ surf_usm_h%ioff |
---|
1929 | j = surf_usm_h(0)%j(m) !+ surf_usm_h%joff |
---|
1930 | k = surf_usm_h(0)%k(m) !+ surf_usm_h%koff |
---|
1931 | local_pf(i,j,k) = surf_usm_h(0)%iwghf_eb(m) |
---|
1932 | ENDDO |
---|
1933 | ENDIF |
---|
1934 | |
---|
1935 | CASE ( 'im_hf_roof_waste' ) |
---|
1936 | IF ( av == 0 ) THEN |
---|
1937 | DO m = 1, surf_usm_h(0)%ns |
---|
1938 | i = surf_usm_h(0)%i(m) !+ surf_usm_h%ioff |
---|
1939 | j = surf_usm_h(0)%j(m) !+ surf_usm_h%joff |
---|
1940 | k = surf_usm_h(0)%k(m) !+ surf_usm_h%koff |
---|
1941 | local_pf(i,j,k) = surf_usm_h(0)%waste_heat(m) |
---|
1942 | ENDDO |
---|
1943 | ENDIF |
---|
1944 | |
---|
1945 | CASE ( 'im_hf_wall_win' ) |
---|
1946 | IF ( av == 0 ) THEN |
---|
1947 | DO l = 0, 3 |
---|
1948 | DO m = 1, surf_usm_v(l)%ns |
---|
1949 | i = surf_usm_v(l)%i(m) !+ surf_usm_v(l)%ioff |
---|
1950 | j = surf_usm_v(l)%j(m) !+ surf_usm_v(l)%joff |
---|
1951 | k = surf_usm_v(l)%k(m) !+ surf_usm_v(l)%koff |
---|
1952 | local_pf(i,j,k) = surf_usm_v(l)%iwghf_eb(m) |
---|
1953 | ENDDO |
---|
1954 | ENDDO |
---|
1955 | ENDIF |
---|
1956 | |
---|
1957 | CASE ( 'im_hf_wall_win_waste' ) |
---|
1958 | IF ( av == 0 ) THEN |
---|
1959 | DO l = 0, 3 |
---|
1960 | DO m = 1, surf_usm_v(l)%ns |
---|
1961 | i = surf_usm_v(l)%i(m) !+ surf_usm_v(l)%ioff |
---|
1962 | j = surf_usm_v(l)%j(m) !+ surf_usm_v(l)%joff |
---|
1963 | k = surf_usm_v(l)%k(m) !+ surf_usm_v(l)%koff |
---|
1964 | local_pf(i,j,k) = surf_usm_v(l)%waste_heat(m) |
---|
1965 | ENDDO |
---|
1966 | ENDDO |
---|
1967 | ENDIF |
---|
1968 | |
---|
1969 | ! |
---|
1970 | !< NOTE im_t_indoor_roof and im_t_indoor_wall_win not work yet |
---|
1971 | |
---|
1972 | ! CASE ( 'im_t_indoor_roof' ) |
---|
1973 | ! IF ( av == 0 ) THEN |
---|
1974 | ! DO m = 1, surf_usm_h%ns |
---|
1975 | ! i = surf_usm_h%i(m) !+ surf_usm_h%ioff |
---|
1976 | ! j = surf_usm_h%j(m) !+ surf_usm_h%joff |
---|
1977 | ! k = surf_usm_h%k(m) !+ surf_usm_h%koff |
---|
1978 | ! local_pf(i,j,k) = surf_usm_h%t_indoor(m) |
---|
1979 | ! ENDDO |
---|
1980 | ! ENDIF |
---|
1981 | ! |
---|
1982 | ! CASE ( 'im_t_indoor_wall_win' ) |
---|
1983 | ! IF ( av == 0 ) THEN |
---|
1984 | ! DO l = 0, 3 |
---|
1985 | ! DO m = 1, surf_usm_v(l)%ns |
---|
1986 | ! i = surf_usm_v(l)%i(m) !+ surf_usm_v(l)%ioff |
---|
1987 | ! j = surf_usm_v(l)%j(m) !+ surf_usm_v(l)%joff |
---|
1988 | ! k = surf_usm_v(l)%k(m) !+ surf_usm_v(l)%koff |
---|
1989 | ! local_pf(i,j,k) = surf_usm_v(l)%t_indoor(m) |
---|
1990 | ! ENDDO |
---|
1991 | ! ENDDO |
---|
1992 | ! ENDIF |
---|
1993 | |
---|
1994 | CASE DEFAULT |
---|
1995 | found = .FALSE. |
---|
1996 | |
---|
1997 | END SELECT |
---|
1998 | |
---|
1999 | END SUBROUTINE im_data_output_3d |
---|
2000 | |
---|
2001 | |
---|
2002 | !--------------------------------------------------------------------------------------------------! |
---|
2003 | ! Description: |
---|
2004 | ! ------------ |
---|
2005 | !> Parin for &indoor_parameters for indoor model |
---|
2006 | !--------------------------------------------------------------------------------------------------! |
---|
2007 | SUBROUTINE im_parin |
---|
2008 | |
---|
2009 | USE control_parameters, & |
---|
2010 | ONLY: indoor_model |
---|
2011 | |
---|
2012 | |
---|
2013 | CHARACTER (LEN=80) :: line !< string containing current line of file PARIN |
---|
2014 | |
---|
2015 | NAMELIST /indoor_parameters/ initial_indoor_temperature |
---|
2016 | |
---|
2017 | |
---|
2018 | ! |
---|
2019 | !-- Try to find indoor model package |
---|
2020 | REWIND ( 11 ) |
---|
2021 | line = ' ' |
---|
2022 | DO WHILE ( INDEX( line, '&indoor_parameters' ) == 0 ) |
---|
2023 | READ ( 11, '(A)', END=10 ) line |
---|
2024 | ENDDO |
---|
2025 | BACKSPACE ( 11 ) |
---|
2026 | |
---|
2027 | ! |
---|
2028 | !-- Read user-defined namelist |
---|
2029 | READ ( 11, indoor_parameters ) |
---|
2030 | ! |
---|
2031 | !-- Set flag that indicates that the indoor model is switched on |
---|
2032 | indoor_model = .TRUE. |
---|
2033 | |
---|
2034 | ! |
---|
2035 | !-- Activate spinup (maybe later |
---|
2036 | ! IF ( spinup_time > 0.0_wp ) THEN |
---|
2037 | ! coupling_start_time = spinup_time |
---|
2038 | ! end_time = end_time + spinup_time |
---|
2039 | ! IF ( spinup_pt_mean == 9999999.9_wp ) THEN |
---|
2040 | ! spinup_pt_mean = pt_surface |
---|
2041 | ! ENDIF |
---|
2042 | ! spinup = .TRUE. |
---|
2043 | ! ENDIF |
---|
2044 | |
---|
2045 | 10 CONTINUE |
---|
2046 | |
---|
2047 | END SUBROUTINE im_parin |
---|
2048 | |
---|
2049 | |
---|
2050 | END MODULE indoor_model_mod |
---|