1 | !> @file indoor_model_mod.f90 |
---|
2 | !--------------------------------------------------------------------------------! |
---|
3 | ! This file is part of the PALM model system. |
---|
4 | ! |
---|
5 | ! PALM is free software: you can redistribute it and/or modify it under the |
---|
6 | ! terms of the GNU General Public License as published by the Free Software |
---|
7 | ! Foundation, either version 3 of the License, or (at your option) any later |
---|
8 | ! version. |
---|
9 | ! |
---|
10 | ! PALM is distributed in the hope that it will be useful, but WITHOUT ANY |
---|
11 | ! WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR |
---|
12 | ! A PARTICULAR PURPOSE. See the GNU General Public License for more details. |
---|
13 | ! |
---|
14 | ! You should have received a copy of the GNU General Public License along with |
---|
15 | ! PALM. If not, see <http://www.gnu.org/licenses/>. |
---|
16 | ! |
---|
17 | ! Copyright 2018-2018 Leibniz Universitaet Hannover |
---|
18 | ! Copyright 2018-2018 Hochschule Offenburg |
---|
19 | !--------------------------------------------------------------------------------! |
---|
20 | ! |
---|
21 | ! Current revisions: |
---|
22 | ! ----------------- |
---|
23 | ! |
---|
24 | ! |
---|
25 | ! Former revisions: |
---|
26 | ! ----------------- |
---|
27 | ! $Id: indoor_model_mod.f90 3597 2018-12-04 08:40:18Z suehring $ |
---|
28 | ! Renamed t_surf_10cm to pt_10cm |
---|
29 | ! |
---|
30 | ! 3593 2018-12-03 13:51:13Z kanani |
---|
31 | ! Replace degree symbol by degree_C |
---|
32 | ! |
---|
33 | ! 3524 2018-11-14 13:36:44Z raasch |
---|
34 | ! working precision added to make code Fortran 2008 conform |
---|
35 | ! |
---|
36 | ! 3469 2018-10-30 20:05:07Z kanani |
---|
37 | ! Initial revision (tlang, suehring, kanani, srissman) |
---|
38 | ! |
---|
39 | ! |
---|
40 | ! |
---|
41 | ! Authors: |
---|
42 | ! -------- |
---|
43 | ! @author Tobias Lang |
---|
44 | ! @author Jens Pfafferott |
---|
45 | ! @author Farah Kanani-Suehring |
---|
46 | ! @author Matthias Suehring |
---|
47 | ! @author Sascha RiÃmann |
---|
48 | ! |
---|
49 | ! |
---|
50 | ! Description: |
---|
51 | ! ------------ |
---|
52 | !> <Description of the new module> |
---|
53 | !> Module for Indoor Climate Model (ICM) |
---|
54 | !> The module is based on the DIN EN ISO 13790 with simplified hour-based procedure. |
---|
55 | !> This model is a equivalent circuit diagram of a three-point RC-model (5R1C). |
---|
56 | !> This module differ between indoor-air temperature an average temperature of indoor surfaces which make it prossible to determine thermal comfort |
---|
57 | !> the heat transfer between indoor and outdoor is simplified |
---|
58 | |
---|
59 | !> @todo Replace window_area_per_facade by %frac(1,m) for window |
---|
60 | !> @todo emissivity change for window blinds if solar_protection_on=1 |
---|
61 | !> @todo write datas in netcdf file as output data |
---|
62 | !> @todo reduce the building volume with netto ground surface to take respect costruction areas like walls and ceilings. Have effect on factor_a, factor_c, airchange and lambda_at |
---|
63 | !> |
---|
64 | !> @note Do we allow use of integer flags, or only logical flags? (concerns e.g. cooling_on, heating_on) |
---|
65 | !> @note How to write indoor temperature output to pt array? |
---|
66 | !> |
---|
67 | !> @bug <Enter known bugs here> |
---|
68 | !------------------------------------------------------------------------------! |
---|
69 | MODULE indoor_model_mod |
---|
70 | |
---|
71 | USE control_parameters, & |
---|
72 | ONLY: initializing_actions |
---|
73 | |
---|
74 | USE kinds |
---|
75 | |
---|
76 | USE surface_mod, & |
---|
77 | ONLY: surf_usm_h, surf_usm_v |
---|
78 | |
---|
79 | |
---|
80 | IMPLICIT NONE |
---|
81 | |
---|
82 | ! |
---|
83 | !-- Define data structure for buidlings. |
---|
84 | TYPE build |
---|
85 | |
---|
86 | INTEGER(iwp) :: id !< building ID |
---|
87 | INTEGER(iwp) :: kb_min !< lowest vertical index of a building |
---|
88 | INTEGER(iwp) :: kb_max !< highest vertical index of a building |
---|
89 | INTEGER(iwp) :: num_facades_per_building_h !< total number of horizontal facades elements |
---|
90 | INTEGER(iwp) :: num_facades_per_building_h_l !< number of horizontal facade elements on local subdomain |
---|
91 | INTEGER(iwp) :: num_facades_per_building_v !< total number of vertical facades elements |
---|
92 | INTEGER(iwp) :: num_facades_per_building_v_l !< number of vertical facade elements on local subdomain |
---|
93 | |
---|
94 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: l_v !< index array linking surface-element orientation index |
---|
95 | !< for vertical surfaces with building |
---|
96 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: m_h !< index array linking surface-element index for |
---|
97 | !< horizontal surfaces with building |
---|
98 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: m_v !< index array linking surface-element index for |
---|
99 | !< vertical surfaces with building |
---|
100 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: num_facade_h !< number of horizontal facade elements per buidling |
---|
101 | !< and height level |
---|
102 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: num_facade_v !< number of vertical facades elements per buidling |
---|
103 | !< and height level |
---|
104 | |
---|
105 | LOGICAL :: on_pe = .FALSE. !< flag indicating whether a building with certain ID is on local subdomain |
---|
106 | |
---|
107 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in !< mean building indoor temperature, height dependent |
---|
108 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in_l !< mean building indoor temperature on local subdomain, height dependent |
---|
109 | REAL(wp), DIMENSION(:), ALLOCATABLE :: volume !< total building volume, height dependent |
---|
110 | REAL(wp), DIMENSION(:), ALLOCATABLE :: vol_frac !< fraction of local on total building volume, height dependent |
---|
111 | REAL(wp), DIMENSION(:), ALLOCATABLE :: vpf !< building volume volume per facade element, height dependent |
---|
112 | |
---|
113 | END TYPE build |
---|
114 | |
---|
115 | TYPE(build), DIMENSION(:), ALLOCATABLE :: buildings !< building array |
---|
116 | |
---|
117 | INTEGER(iwp) :: num_build !< total number of buildings in domain |
---|
118 | |
---|
119 | REAL(wp) :: volume_fraction |
---|
120 | |
---|
121 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in !< dummy array for indoor temperature for the |
---|
122 | !< total building volume at each discrete height level |
---|
123 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in_l !< dummy array for indoor temperature for the |
---|
124 | !< local building volume fraction at each discrete height level |
---|
125 | |
---|
126 | ! |
---|
127 | !-- Declare all global variables within the module |
---|
128 | |
---|
129 | INTEGER(iwp) :: building_type = 1 !< namelist parameter with |
---|
130 | !< X1=construction year (cy) 1950, X2=cy 2000, X3=cy 2050 |
---|
131 | !< R=Residental building, O=Office, RW=Enlarged Windows, P=Panel type (Plattenbau) WBS 70, H=Hospital (in progress), I=Industrial halls (in progress), S=Special Building (in progress) |
---|
132 | !< (0=R1, 1=R2, 2=R3, 3=O1, 4=O2, 5=O3,...) |
---|
133 | INTEGER(iwp) :: cooling_on !< Indoor cooling flag (0=off, 1=on) |
---|
134 | INTEGER(iwp) :: heating_on !< Indoor heating flag (0=off, 1=on) |
---|
135 | INTEGER(iwp) :: solar_protection_off !< Solar protection off |
---|
136 | INTEGER(iwp) :: solar_protection_on !< Solar protection on |
---|
137 | |
---|
138 | REAL(wp) :: air_change_high !< [1/h] air changes per time_utc_hour |
---|
139 | REAL(wp) :: air_change_low !< [1/h] air changes per time_utc_hour |
---|
140 | REAL(wp) :: eff_mass_area !< [m²] the effective mass-related area |
---|
141 | REAL(wp) :: floor_area_per_facade !< [m²] net floor area (Sum of all floors) |
---|
142 | REAL(wp) :: total_area !<! [m²] area of all surfaces pointing to zone |
---|
143 | REAL(wp) :: window_area_per_facade !< [m2] window area per facade element |
---|
144 | REAL(wp) :: air_change !< [1/h] Airflow |
---|
145 | REAL(wp) :: bldg_part_surf_i = 4 !< [m²_surf,i] part building surface, from Palm, das mÌsste mittlerweile "facade_element_area" sein! |
---|
146 | REAL(wp) :: facade_element_area !< [m²_facade] building surface facade |
---|
147 | REAL(wp) :: indoor_volume_per_facade !< [m³] indoor air volume per facade element |
---|
148 | REAL(wp) :: c_m !< [J/K] internal heat storage capacity |
---|
149 | REAL(wp) :: dt_indoor = 3600.0_wp !< [s] namelist parameter: time interval for indoor-model application |
---|
150 | REAL(wp) :: eta_ve !< [-] heat recovery efficiency |
---|
151 | REAL(wp) :: f_c_win !< [-] shading factor |
---|
152 | REAL(wp) :: factor_a !< [-] Dynamic parameters specific effective surface according to Table 12; 2.5 (very light, light and medium), 3.0 (heavy), 3.5 (very heavy) |
---|
153 | REAL(wp) :: factor_c !< [J/(m2 K)] Dynamic parameters inner heatstorage according to Table 12; 80000 (very light), 110000 (light), 165000 (medium), 260000 (heavy), 370000 (very heavy) |
---|
154 | REAL(wp) :: g_value_win !< [-] SHGC factor |
---|
155 | REAL(wp) :: h_tr_1 !<! [W/K] Heat transfer coefficient auxiliary variable 1 |
---|
156 | REAL(wp) :: h_tr_2 !<! [W/K] Heat transfer coefficient auxiliary variable 2 |
---|
157 | REAL(wp) :: h_tr_3 !<! [W/K] Heat transfer coefficient auxiliary variable 3 |
---|
158 | REAL(wp) :: h_tr_em !<! [W/K] Heat transfer coefficient of the emmision (got with h_tr_ms the thermal mass) |
---|
159 | REAL(wp) :: h_tr_is !<! [W/K] thermal coupling conductance (Thermischer Kopplungsleitwert) |
---|
160 | REAL(wp) :: h_tr_ms !<! [W/K] Heat transfer conductance term (got with h_tr_em the thermal mass) |
---|
161 | REAL(wp) :: h_tr_op !<! [W/K] heat transfer coefficient of opaque components (assumption: got all thermal mass) contains of h_tr_em and h_tr_ms |
---|
162 | REAL(wp) :: h_tr_w !<! [W/K] heat transfer coefficient of doors, windows, curtain walls and glazed walls (assumption: thermal mass=0) |
---|
163 | REAL(wp) :: h_ve !<! [W/K] heat transfer of ventilation |
---|
164 | REAL(wp) :: height_storey !< [m] storey heigth |
---|
165 | REAL(wp) :: height_cei_con !< [m] ceiling construction heigth |
---|
166 | REAL(wp) :: initial_indoor_temperature !< namelist parameter |
---|
167 | REAL(wp) :: lambda_at !< [-] ratio internal surface/floor area chap. 7.2.2.2. |
---|
168 | REAL(wp) :: lambda_layer3 !< [W/(m*K)] Thermal conductivity of the inner layer |
---|
169 | REAL(wp) :: net_sw_in !< net short-wave radiation (in - out; was i_global --> CORRECT?) |
---|
170 | REAL(wp) :: qint_high !< [W/m2] internal heat gains, option Database qint_0-23 |
---|
171 | REAL(wp) :: qint_low !< [W/m2] internal heat gains, option Database qint_0-23 |
---|
172 | REAL(wp) :: phi_c_max !< [W] Max. Cooling capacity (negative) |
---|
173 | REAL(wp) :: phi_h_max !< [W] Max. Heating capacity (negative) |
---|
174 | REAL(wp) :: phi_hc_nd !<! [W] heating demand and/or cooling demand |
---|
175 | REAL(wp) :: phi_hc_nd_10 !<! [W] heating demand and/or cooling demand for heating or cooling |
---|
176 | REAL(wp) :: phi_hc_nd_ac !<! [W] actual heating demand and/or cooling demand |
---|
177 | REAL(wp) :: phi_hc_nd_un !<! [W] unlimited heating demand and/or cooling demand which is necessary to reach the demanded required temperature (heating is positive, cooling is negative) |
---|
178 | REAL(wp) :: phi_ia !< [W] internal air load = internal loads * 0.5, Eq. (C.1) |
---|
179 | REAL(wp) :: phi_m !<! [W] mass specific thermal load (internal and external) |
---|
180 | REAL(wp) :: phi_mtot !<! [W] total mass specific thermal load (internal and external) |
---|
181 | REAL(wp) :: phi_sol !< [W] solar loads |
---|
182 | REAL(wp) :: phi_st !<! [W] mass specific thermal load implied non thermal mass |
---|
183 | REAL(wp) :: q_emission !< emissions, in first version = 0, option for second part of the project |
---|
184 | REAL(wp) :: q_wall_win !< heat flux from indoor into wall/window |
---|
185 | REAL(wp) :: q_waste_heat !< waste heat, sum of waste heat over the roof to Palm |
---|
186 | REAL(wp) :: q_waste_heat_bldg !< [W/building] waste heat of the complete building, in Palm sum of all indoor_model-calculations |
---|
187 | REAL(wp) :: s_layer3 !< [m] half thickness of the inner layer (layer_3) |
---|
188 | REAL(wp) :: schedule_d !< activation for internal loads (low or high + low) |
---|
189 | REAL(wp) :: skip_time_do_indoor = 0.0_wp !< [s] Indoor model is not called before this time |
---|
190 | REAL(wp) :: theta_air !<! [degree_C] air temperature of the RC-node |
---|
191 | REAL(wp) :: theta_air_0 !<! [degree_C] air temperature of the RC-node in equilibrium |
---|
192 | REAL(wp) :: theta_air_10 !<! [degree_C] air temperature of the RC-node from a heating capacity of 10 W/m² |
---|
193 | REAL(wp) :: theta_air_ac !< [degree_C] actual room temperature after heating/cooling |
---|
194 | REAL(wp) :: theta_air_set !< [degree_C] Setpoint_temperature for the room |
---|
195 | REAL(wp) :: theta_int_c_set !< [degree_C] Max. Setpoint temperature (summer) |
---|
196 | REAL(wp) :: theta_int_h_set !< [degree_C] Max. Setpoint temperature (winter) |
---|
197 | REAL(wp) :: theta_m !<! [degree_C} inner temperature of the RC-node |
---|
198 | REAL(wp) :: theta_m_t !<! [degree_C] (Fictive) component temperature timestep |
---|
199 | REAL(wp) :: theta_m_t_prev !< [degree_C] (Fictive) component temperature previous timestep (do not change) |
---|
200 | REAL(wp) :: theta_op !< [degree_C] operative temperature |
---|
201 | REAL(wp) :: theta_s !<! [degree_C] surface temperature of the RC-node |
---|
202 | REAL(wp) :: time_indoor = 0.0_wp !< [s] time since last call of indoor model |
---|
203 | REAL(wp) :: time_utc_hour !< Time in hours per day (UTC) |
---|
204 | REAL(wp) :: u_value_win !< [W/(m2*K)] transmittance |
---|
205 | REAL(wp) :: ventilation_int_loads !< Zuteilung der GebÀude fÌr Verlauf/AktivitÀt der LÌftung und internen Lasten |
---|
206 | |
---|
207 | ! |
---|
208 | !-- Declare all global parameters within the module |
---|
209 | REAL(wp), PARAMETER :: params_f_f = 0.3_wp !< [-] frame ratio chap. 8.3.2.1.1 for buildings with mostly cooling 2.0_wp |
---|
210 | REAL(wp), PARAMETER :: params_f_w = 0.9_wp !< [-] correction factor (fuer nicht senkrechten Stahlungseinfall DIN 4108-2 chap.8, (hier konstant, keine WinkelabhÀngigkeit) |
---|
211 | REAL(wp), PARAMETER :: params_f_win = 0.5_wp !< [-] proportion of window area, Database A_win aus Datenbank 27 window_area_per_facade_percent |
---|
212 | REAL(wp), PARAMETER :: params_solar_protection = 300.0_wp !< [W/m2] chap. G.5.3.1 sun protection closed, if the radiation on facade exceeds this value |
---|
213 | REAL(wp), PARAMETER :: params_waste_heat_c = 4.0_wp !< [-] anthropogenic heat outputs for cooling e.g. 4 for KKM with COP = 3 |
---|
214 | REAL(wp), PARAMETER :: params_waste_heat_h = 1.111_wp !< [-] anthropogenic heat outputs for heating e.g. 1 / 0.9 = 1.111111 for combustion with eta = 0.9 or -3 for WP with COP = 4 |
---|
215 | REAL(wp), PARAMETER :: h_is = 3.45_wp !< [W/(m^2 K)] h_is = 3.45 between surface and air (chap. 7.2.2.2) |
---|
216 | REAL(wp), PARAMETER :: h_ms = 9.1_wp !< [W/K] h_ms = 9.10 W / (m2 K) between component and surface (chap. 12.2.2) |
---|
217 | |
---|
218 | SAVE |
---|
219 | |
---|
220 | |
---|
221 | PRIVATE |
---|
222 | |
---|
223 | ! |
---|
224 | !-- Add INTERFACES that must be available to other modules |
---|
225 | PUBLIC im_init, im_main_heatcool, im_parin |
---|
226 | |
---|
227 | ! |
---|
228 | !-- Add VARIABLES that must be available to other modules |
---|
229 | PUBLIC dt_indoor, skip_time_do_indoor, time_indoor |
---|
230 | |
---|
231 | ! |
---|
232 | !-- Calculations for indoor temperatures |
---|
233 | INTERFACE im_calc_temperatures |
---|
234 | MODULE PROCEDURE im_calc_temperatures |
---|
235 | END INTERFACE im_calc_temperatures |
---|
236 | ! |
---|
237 | !-- Initialization actions |
---|
238 | INTERFACE im_init |
---|
239 | MODULE PROCEDURE im_init |
---|
240 | END INTERFACE im_init |
---|
241 | |
---|
242 | ! |
---|
243 | !-- Main part of indoor model |
---|
244 | INTERFACE im_main_heatcool |
---|
245 | MODULE PROCEDURE im_main_heatcool |
---|
246 | END INTERFACE im_main_heatcool |
---|
247 | ! |
---|
248 | !-- Reading of NAMELIST parameters |
---|
249 | INTERFACE im_parin |
---|
250 | MODULE PROCEDURE im_parin |
---|
251 | END INTERFACE im_parin |
---|
252 | |
---|
253 | CONTAINS |
---|
254 | |
---|
255 | !------------------------------------------------------------------------------! |
---|
256 | ! Description: |
---|
257 | ! ------------ |
---|
258 | !< Calculation of the air temperatures and mean radiation temperature |
---|
259 | !< This is basis for the operative temperature |
---|
260 | !< Based on a Crank-Nicholson scheme with a timestep of a hour |
---|
261 | !------------------------------------------------------------------------------! |
---|
262 | SUBROUTINE im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
263 | near_facade_temperature, phi_hc_nd_dummy ) |
---|
264 | |
---|
265 | USE arrays_3d, & |
---|
266 | ONLY: pt |
---|
267 | |
---|
268 | |
---|
269 | IMPLICIT NONE |
---|
270 | |
---|
271 | |
---|
272 | INTEGER(iwp) :: i |
---|
273 | INTEGER(iwp) :: j |
---|
274 | INTEGER(iwp) :: k |
---|
275 | |
---|
276 | REAL(wp) :: indoor_wall_window_temperature !< weighted temperature of innermost wall/window layer |
---|
277 | REAL(wp) :: near_facade_temperature |
---|
278 | REAL(wp) :: phi_hc_nd_dummy |
---|
279 | |
---|
280 | !< Calculation of total mass specific thermal load (internal and external) |
---|
281 | phi_mtot = ( phi_m + h_tr_em * indoor_wall_window_temperature & |
---|
282 | + h_tr_3 * ( phi_st + h_tr_w * pt(k,j,i) & |
---|
283 | + h_tr_1 * & |
---|
284 | ( ( ( phi_ia + phi_hc_nd_dummy ) / h_ve ) & |
---|
285 | + near_facade_temperature ) & |
---|
286 | ) / h_tr_2 & |
---|
287 | ) !< [degree_C] Eq. (C.5) |
---|
288 | |
---|
289 | !< Calculation of component temperature at factual timestep |
---|
290 | theta_m_t = ( ( theta_m_t_prev & |
---|
291 | * ( ( c_m / 3600 ) - 0.5 * ( h_tr_3 + h_tr_em ) ) + phi_mtot & |
---|
292 | ) & |
---|
293 | / ( ( c_m / 3600 ) + 0.5 * ( h_tr_3 + h_tr_em ) ) & |
---|
294 | ) !< [degree_C] Eq. (C.4) |
---|
295 | |
---|
296 | !< Calculation of mean inner temperature for the RC-node in actual timestep |
---|
297 | theta_m = ( theta_m_t + theta_m_t_prev ) * 0.5 !< [degree_C] Eq. (C.9) |
---|
298 | |
---|
299 | !< Calculation of mean surface temperature of the RC-node in actual timestep |
---|
300 | theta_s = ( ( h_tr_ms * theta_m + phi_st + h_tr_w * pt(k,j,i) & |
---|
301 | + h_tr_1 * ( near_facade_temperature + ( phi_ia + phi_hc_nd_dummy ) / h_ve ) & |
---|
302 | ) & |
---|
303 | / ( h_tr_ms + h_tr_w + h_tr_1 ) & |
---|
304 | ) !< [degree_C] Eq. (C.10) |
---|
305 | |
---|
306 | !< Calculation of the air temperature of the RC-node |
---|
307 | theta_air = ( h_tr_is * theta_s + h_ve * near_facade_temperature & |
---|
308 | + phi_ia + phi_hc_nd_dummy ) / ( h_tr_is + h_ve ) !< [degree_C] Eq. (C.11) |
---|
309 | |
---|
310 | END SUBROUTINE im_calc_temperatures |
---|
311 | |
---|
312 | !------------------------------------------------------------------------------! |
---|
313 | ! Description: |
---|
314 | ! ------------ |
---|
315 | !> Initialization of the indoor model. |
---|
316 | !> Static information are calculated here, e.g. building parameters and |
---|
317 | !> geometrical information, everything that doesn't change in time. |
---|
318 | ! |
---|
319 | !-- Input values |
---|
320 | !-- Input datas from Palm, M4 |
---|
321 | ! i_global --> net_sw_in !global radiation [W/m2] |
---|
322 | ! theta_e --> pt(k,j,i) !undisturbed outside temperature, 1. PALM volume, for windows |
---|
323 | ! theta_sup = theta_f --> surf_usm_h%pt_10cm(m) |
---|
324 | ! surf_usm_v(l)%pt_10cm(m) !Air temperature, facade near (10cm) air temperature from 1. Palm volume |
---|
325 | ! theta_node --> t_wall_h(nzt_wall,m) |
---|
326 | ! t_wall_v(l)%t(nzt_wall,m) !Temperature of innermost wall layer, for opaque wall |
---|
327 | !------------------------------------------------------------------------------! |
---|
328 | SUBROUTINE im_init |
---|
329 | |
---|
330 | USE arrays_3d, & |
---|
331 | ONLY: dzw |
---|
332 | |
---|
333 | USE control_parameters, & |
---|
334 | ONLY: message_string |
---|
335 | |
---|
336 | USE indices, & |
---|
337 | ONLY: nxl, nxr, nyn, nys, nzb, nzt, wall_flags_0 |
---|
338 | |
---|
339 | USE grid_variables, & |
---|
340 | ONLY: dx, dy |
---|
341 | |
---|
342 | USE netcdf_data_input_mod, & |
---|
343 | ONLY: building_id_f |
---|
344 | |
---|
345 | USE pegrid |
---|
346 | |
---|
347 | USE surface_mod, & |
---|
348 | ONLY: surf_usm_h, surf_usm_v |
---|
349 | |
---|
350 | USE urban_surface_mod, & |
---|
351 | ONLY: building_pars, building_type |
---|
352 | |
---|
353 | IMPLICIT NONE |
---|
354 | |
---|
355 | INTEGER(iwp) :: fa !< running index for facade elements of each building |
---|
356 | INTEGER(iwp) :: i !< running index along x-direction |
---|
357 | INTEGER(iwp) :: j !< running index along y-direction |
---|
358 | INTEGER(iwp) :: k !< running index along z-direction |
---|
359 | INTEGER(iwp) :: l !< running index for surface-element orientation |
---|
360 | INTEGER(iwp) :: m !< running index surface elements |
---|
361 | INTEGER(iwp) :: n !< building index |
---|
362 | INTEGER(iwp) :: nb !< building index |
---|
363 | |
---|
364 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids !< building IDs on entire model domain |
---|
365 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids_final !< building IDs on entire model domain, |
---|
366 | !< multiple occurences are sorted out |
---|
367 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids_final_tmp !< temporary array used for resizing |
---|
368 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids_l !< building IDs on local subdomain |
---|
369 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: build_ids_l_tmp !< temporary array used to resize array of building IDs |
---|
370 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: displace_dum !< displacements of start addresses, used for MPI_ALLGATHERV |
---|
371 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: k_max_l !< highest vertical index of a building on subdomain |
---|
372 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: k_min_l !< lowest vertical index of a building on subdomain |
---|
373 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: n_fa !< counting array |
---|
374 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: num_facades_h !< dummy array used for summing-up total number of |
---|
375 | !< horizontal facade elements |
---|
376 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: num_facades_v !< dummy array used for summing-up total number of |
---|
377 | !< vertical facade elements |
---|
378 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: receive_dum_h !< dummy array used for MPI_ALLREDUCE |
---|
379 | INTEGER(iwp), DIMENSION(:), ALLOCATABLE :: receive_dum_v !< dummy array used for MPI_ALLREDUCE |
---|
380 | |
---|
381 | INTEGER(iwp), DIMENSION(0:numprocs-1) :: num_buildings !< number of buildings with different ID on entire model domain |
---|
382 | INTEGER(iwp), DIMENSION(0:numprocs-1) :: num_buildings_l !< number of buildings with different ID on local subdomain |
---|
383 | |
---|
384 | REAL(wp), DIMENSION(:), ALLOCATABLE :: local_weight !< dummy representing fraction of local on total building volume, |
---|
385 | !< height dependent |
---|
386 | REAL(wp), DIMENSION(:), ALLOCATABLE :: volume !< total building volume at each discrete height level |
---|
387 | REAL(wp), DIMENSION(:), ALLOCATABLE :: volume_l !< total building volume at each discrete height level, |
---|
388 | !< on local subdomain |
---|
389 | |
---|
390 | ! |
---|
391 | !-- Initializing of indoor model is only possible if buildings can be |
---|
392 | !-- distinguished by their IDs. |
---|
393 | IF ( .NOT. building_id_f%from_file ) THEN |
---|
394 | message_string = 'Indoor model requires information about building_id' |
---|
395 | CALL message( 'im_init', 'PA0999', 1, 2, 0, 6, 0 ) |
---|
396 | ENDIF |
---|
397 | ! |
---|
398 | !-- Determine number of different building IDs on local subdomain. |
---|
399 | num_buildings_l = 0 |
---|
400 | num_buildings = 0 |
---|
401 | ALLOCATE( build_ids_l(1) ) |
---|
402 | DO i = nxl, nxr |
---|
403 | DO j = nys, nyn |
---|
404 | IF ( building_id_f%var(j,i) /= building_id_f%fill ) THEN |
---|
405 | IF ( num_buildings_l(myid) > 0 ) THEN |
---|
406 | IF ( ANY( building_id_f%var(j,i) .EQ. build_ids_l ) ) THEN |
---|
407 | CYCLE |
---|
408 | ELSE |
---|
409 | num_buildings_l(myid) = num_buildings_l(myid) + 1 |
---|
410 | ! |
---|
411 | !-- Resize array with different local building ids |
---|
412 | ALLOCATE( build_ids_l_tmp(1:SIZE(build_ids_l)) ) |
---|
413 | build_ids_l_tmp = build_ids_l |
---|
414 | DEALLOCATE( build_ids_l ) |
---|
415 | ALLOCATE( build_ids_l(1:num_buildings_l(myid)) ) |
---|
416 | build_ids_l(1:num_buildings_l(myid)-1) = & |
---|
417 | build_ids_l_tmp(1:num_buildings_l(myid)-1) |
---|
418 | build_ids_l(num_buildings_l(myid)) = building_id_f%var(j,i) |
---|
419 | DEALLOCATE( build_ids_l_tmp ) |
---|
420 | ENDIF |
---|
421 | ! |
---|
422 | !-- First occuring building id on PE |
---|
423 | ELSE |
---|
424 | num_buildings_l(myid) = num_buildings_l(myid) + 1 |
---|
425 | build_ids_l(1) = building_id_f%var(j,i) |
---|
426 | ENDIF |
---|
427 | ENDIF |
---|
428 | ENDDO |
---|
429 | ENDDO |
---|
430 | ! |
---|
431 | !-- Determine number of building IDs for the entire domain. (Note, building IDs |
---|
432 | !-- can appear multiple times as buildings might be distributed over several |
---|
433 | !-- PEs.) |
---|
434 | #if defined( __parallel ) |
---|
435 | CALL MPI_ALLREDUCE( num_buildings_l, num_buildings, numprocs, & |
---|
436 | MPI_INTEGER, MPI_SUM, comm2d, ierr ) |
---|
437 | #else |
---|
438 | num_buildings = num_buildings_l |
---|
439 | #endif |
---|
440 | ALLOCATE( build_ids(1:SUM(num_buildings)) ) |
---|
441 | ! |
---|
442 | !-- Gather building IDs. Therefore, first, determine displacements used |
---|
443 | !-- required for MPI_GATHERV call. |
---|
444 | ALLOCATE( displace_dum(0:numprocs-1) ) |
---|
445 | displace_dum(0) = 0 |
---|
446 | DO i = 1, numprocs-1 |
---|
447 | displace_dum(i) = displace_dum(i-1) + num_buildings(i-1) |
---|
448 | ENDDO |
---|
449 | |
---|
450 | #if defined( __parallel ) |
---|
451 | CALL MPI_ALLGATHERV( build_ids_l(1:num_buildings_l(myid)), & |
---|
452 | num_buildings(myid), & |
---|
453 | MPI_INTEGER, & |
---|
454 | build_ids, & |
---|
455 | num_buildings, & |
---|
456 | displace_dum, & |
---|
457 | MPI_INTEGER, & |
---|
458 | comm2d, ierr ) |
---|
459 | |
---|
460 | DEALLOCATE( displace_dum ) |
---|
461 | |
---|
462 | #else |
---|
463 | build_ids = build_ids_l |
---|
464 | #endif |
---|
465 | ! |
---|
466 | !-- Note: in parallel mode, building IDs can occur mutliple times, as |
---|
467 | !-- each PE has send its own ids. Therefore, sort out building IDs which |
---|
468 | !-- appear multiple times. |
---|
469 | num_build = 0 |
---|
470 | DO n = 1, SIZE(build_ids) |
---|
471 | |
---|
472 | IF ( ALLOCATED(build_ids_final) ) THEN |
---|
473 | IF ( ANY( build_ids(n) .EQ. build_ids_final ) ) THEN !FK: Warum ANY?, Warum .EQ.? --> s.o |
---|
474 | CYCLE |
---|
475 | ELSE |
---|
476 | num_build = num_build + 1 |
---|
477 | ! |
---|
478 | !-- Resize |
---|
479 | ALLOCATE( build_ids_final_tmp(1:num_build) ) |
---|
480 | build_ids_final_tmp(1:num_build-1) = build_ids_final(1:num_build-1) |
---|
481 | DEALLOCATE( build_ids_final ) |
---|
482 | ALLOCATE( build_ids_final(1:num_build) ) |
---|
483 | build_ids_final(1:num_build-1) = build_ids_final_tmp(1:num_build-1) |
---|
484 | build_ids_final(num_build) = build_ids(n) |
---|
485 | DEALLOCATE( build_ids_final_tmp ) |
---|
486 | ENDIF |
---|
487 | ELSE |
---|
488 | num_build = num_build + 1 |
---|
489 | ALLOCATE( build_ids_final(1:num_build) ) |
---|
490 | build_ids_final(num_build) = build_ids(n) |
---|
491 | ENDIF |
---|
492 | ENDDO |
---|
493 | |
---|
494 | ! |
---|
495 | !-- Allocate building-data structure array. Note, this is a global array |
---|
496 | !-- and all building IDs on domain are known by each PE. Further attributes, |
---|
497 | !-- e.g. height-dependent arrays, however, are only allocated on PEs where |
---|
498 | !-- the respective building is present (in order to reduce memory demands). |
---|
499 | ALLOCATE( buildings(1:num_build) ) |
---|
500 | ! |
---|
501 | !-- Store building IDs and check if building with certain ID is present on |
---|
502 | !-- subdomain. |
---|
503 | DO nb = 1, num_build |
---|
504 | buildings(nb)%id = build_ids_final(nb) |
---|
505 | |
---|
506 | IF ( ANY( building_id_f%var == buildings(nb)%id ) ) & |
---|
507 | buildings(nb)%on_pe = .TRUE. |
---|
508 | ENDDO |
---|
509 | ! |
---|
510 | !-- Determine the maximum vertical dimension occupied by each building. |
---|
511 | ALLOCATE( k_min_l(1:num_build) ) |
---|
512 | ALLOCATE( k_max_l(1:num_build) ) |
---|
513 | k_min_l = nzt + 1 |
---|
514 | k_max_l = 0 |
---|
515 | |
---|
516 | DO i = nxl, nxr |
---|
517 | DO j = nys, nyn |
---|
518 | IF ( building_id_f%var(j,i) /= building_id_f%fill ) THEN |
---|
519 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), & |
---|
520 | DIM = 1 ) |
---|
521 | DO k = nzb+1, nzt+1 |
---|
522 | ! |
---|
523 | !-- Check if grid point belongs to a building. |
---|
524 | IF ( BTEST( wall_flags_0(k,j,i), 6 ) ) THEN |
---|
525 | k_min_l(nb) = MIN( k_min_l(nb), k ) |
---|
526 | k_max_l(nb) = MAX( k_max_l(nb), k ) |
---|
527 | ENDIF |
---|
528 | |
---|
529 | ENDDO |
---|
530 | ENDIF |
---|
531 | ENDDO |
---|
532 | ENDDO |
---|
533 | |
---|
534 | DO nb = 1, num_build |
---|
535 | #if defined( __parallel ) |
---|
536 | CALL MPI_ALLREDUCE( k_min_l(nb), buildings(nb)%kb_min, 1, MPI_INTEGER, & |
---|
537 | MPI_MIN, comm2d, ierr ) |
---|
538 | CALL MPI_ALLREDUCE( k_max_l(nb), buildings(nb)%kb_max, 1, MPI_INTEGER, & |
---|
539 | MPI_MAX, comm2d, ierr ) |
---|
540 | #else |
---|
541 | buildings(nb)%kb_min = k_min_l(nb) |
---|
542 | buildings(nb)%kb_max = k_max_l(nb) |
---|
543 | #endif |
---|
544 | |
---|
545 | ENDDO |
---|
546 | |
---|
547 | DEALLOCATE( k_min_l ) |
---|
548 | DEALLOCATE( k_max_l ) |
---|
549 | ! |
---|
550 | !-- Calculate building volume |
---|
551 | DO nb = 1, num_build |
---|
552 | ! |
---|
553 | !-- Allocate temporary array for summing-up building volume |
---|
554 | ALLOCATE( volume(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
555 | ALLOCATE( volume_l(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
556 | volume = 0.0_wp |
---|
557 | volume_l = 0.0_wp |
---|
558 | ! |
---|
559 | !-- Calculate building volume per height level on each PE where |
---|
560 | !-- these building is present. |
---|
561 | IF ( buildings(nb)%on_pe ) THEN |
---|
562 | ALLOCATE( buildings(nb)%volume(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
563 | ALLOCATE( buildings(nb)%vol_frac(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
564 | buildings(nb)%volume = 0.0_wp |
---|
565 | buildings(nb)%vol_frac = 0.0_wp |
---|
566 | |
---|
567 | IF ( ANY( building_id_f%var == buildings(nb)%id ) ) THEN |
---|
568 | DO i = nxl, nxr |
---|
569 | DO j = nys, nyn |
---|
570 | DO k = buildings(nb)%kb_min, buildings(nb)%kb_max |
---|
571 | IF ( building_id_f%var(j,i) /= building_id_f%fill ) & |
---|
572 | volume_l(k) = dx * dy * dzw(k) |
---|
573 | ENDDO |
---|
574 | ENDDO |
---|
575 | ENDDO |
---|
576 | ENDIF |
---|
577 | ENDIF |
---|
578 | ! |
---|
579 | !-- Sum-up building volume from all subdomains |
---|
580 | #if defined( __parallel ) |
---|
581 | CALL MPI_ALLREDUCE( volume_l, volume, SIZE(volume), MPI_REAL, MPI_SUM, & |
---|
582 | comm2d, ierr ) |
---|
583 | #else |
---|
584 | volume = volume_l |
---|
585 | #endif |
---|
586 | ! |
---|
587 | !-- Save total building volume as well as local fraction on volume on |
---|
588 | !-- building data structure. |
---|
589 | IF ( ALLOCATED( buildings(nb)%volume ) ) buildings(nb)%volume = volume |
---|
590 | ! |
---|
591 | !-- Determine fraction of local on total building volume |
---|
592 | IF ( buildings(nb)%on_pe ) buildings(nb)%vol_frac = volume_l / volume |
---|
593 | |
---|
594 | DEALLOCATE( volume ) |
---|
595 | DEALLOCATE( volume_l ) |
---|
596 | |
---|
597 | ENDDO |
---|
598 | |
---|
599 | ! |
---|
600 | !-- Allocate arrays for indoor temperature. |
---|
601 | DO nb = 1, num_build |
---|
602 | IF ( buildings(nb)%on_pe ) THEN |
---|
603 | ALLOCATE( buildings(nb)%t_in(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
604 | ALLOCATE( buildings(nb)%t_in_l(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
605 | buildings(nb)%t_in = 0.0_wp |
---|
606 | buildings(nb)%t_in_l = 0.0_wp |
---|
607 | ENDIF |
---|
608 | ENDDO |
---|
609 | ! |
---|
610 | !-- Allocate arrays for number of facades per height level. Distinguish between |
---|
611 | !-- horizontal and vertical facades. |
---|
612 | DO nb = 1, num_build |
---|
613 | IF ( buildings(nb)%on_pe ) THEN |
---|
614 | ALLOCATE( buildings(nb)%num_facade_h(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
615 | ALLOCATE( buildings(nb)%num_facade_v(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
616 | |
---|
617 | buildings(nb)%num_facade_h = 0 |
---|
618 | buildings(nb)%num_facade_v = 0 |
---|
619 | ENDIF |
---|
620 | ENDDO |
---|
621 | ! |
---|
622 | !-- Determine number of facade elements per building on local subdomain. |
---|
623 | !-- Distinguish between horizontal and vertical facade elements. |
---|
624 | ! |
---|
625 | !-- Horizontal facades |
---|
626 | buildings(:)%num_facades_per_building_h_l = 0 |
---|
627 | DO m = 1, surf_usm_h%ns |
---|
628 | ! |
---|
629 | !-- For the current facade element determine corresponding building index. |
---|
630 | !-- First, obtain j,j,k indices of the building. Please note the |
---|
631 | !-- offset between facade/surface element and building location (for |
---|
632 | !-- horizontal surface elements the horizontal offsets are zero). |
---|
633 | i = surf_usm_h%i(m) + surf_usm_h%ioff |
---|
634 | j = surf_usm_h%j(m) + surf_usm_h%joff |
---|
635 | k = surf_usm_h%k(m) + surf_usm_h%koff |
---|
636 | ! |
---|
637 | !-- Determine building index and check whether building is on PE |
---|
638 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM = 1 ) |
---|
639 | IF ( buildings(nb)%on_pe ) THEN |
---|
640 | ! |
---|
641 | !-- Count number of facade elements at each height level. |
---|
642 | buildings(nb)%num_facade_h(k) = buildings(nb)%num_facade_h(k) + 1 |
---|
643 | ! |
---|
644 | !-- Moreover, sum up number of local facade elements per building. |
---|
645 | buildings(nb)%num_facades_per_building_h_l = & |
---|
646 | buildings(nb)%num_facades_per_building_h_l + 1 |
---|
647 | ENDIF |
---|
648 | ENDDO |
---|
649 | ! |
---|
650 | !-- Vertical facades |
---|
651 | buildings(:)%num_facades_per_building_v_l = 0 |
---|
652 | DO l = 0, 3 |
---|
653 | DO m = 1, surf_usm_v(l)%ns |
---|
654 | ! |
---|
655 | !-- For the current facade element determine corresponding building index. |
---|
656 | !-- First, obtain j,j,k indices of the building. Please note the |
---|
657 | !-- offset between facade/surface element and building location (for |
---|
658 | !-- vertical surface elements the vertical offsets are zero). |
---|
659 | i = surf_usm_v(l)%i(m) + surf_usm_v(l)%ioff |
---|
660 | j = surf_usm_v(l)%j(m) + surf_usm_v(l)%joff |
---|
661 | k = surf_usm_v(l)%k(m) + surf_usm_v(l)%koff |
---|
662 | |
---|
663 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), & |
---|
664 | DIM = 1 ) |
---|
665 | IF ( buildings(nb)%on_pe ) THEN |
---|
666 | buildings(nb)%num_facade_v(k) = buildings(nb)%num_facade_v(k) + 1 |
---|
667 | buildings(nb)%num_facades_per_building_v_l = & |
---|
668 | buildings(nb)%num_facades_per_building_v_l + 1 |
---|
669 | ENDIF |
---|
670 | ENDDO |
---|
671 | ENDDO |
---|
672 | |
---|
673 | ! |
---|
674 | !-- Determine total number of facade elements per building and assign number to |
---|
675 | !-- building data type. |
---|
676 | DO nb = 1, num_build |
---|
677 | ! |
---|
678 | !-- Allocate dummy array used for summing-up facade elements. |
---|
679 | !-- Please note, dummy arguments are necessary as building-date type |
---|
680 | !-- arrays are not necessarily allocated on all PEs. |
---|
681 | ALLOCATE( num_facades_h(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
682 | ALLOCATE( num_facades_v(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
683 | ALLOCATE( receive_dum_h(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
684 | ALLOCATE( receive_dum_v(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
685 | num_facades_h = 0 |
---|
686 | num_facades_v = 0 |
---|
687 | receive_dum_h = 0 |
---|
688 | receive_dum_v = 0 |
---|
689 | |
---|
690 | IF ( buildings(nb)%on_pe ) THEN |
---|
691 | num_facades_h = buildings(nb)%num_facade_h |
---|
692 | num_facades_v = buildings(nb)%num_facade_v |
---|
693 | ENDIF |
---|
694 | |
---|
695 | #if defined( __parallel ) |
---|
696 | CALL MPI_ALLREDUCE( num_facades_h, & |
---|
697 | receive_dum_h, & |
---|
698 | buildings(nb)%kb_max - buildings(nb)%kb_min + 1, & |
---|
699 | MPI_INTEGER, & |
---|
700 | MPI_SUM, & |
---|
701 | comm2d, & |
---|
702 | ierr ) |
---|
703 | |
---|
704 | CALL MPI_ALLREDUCE( num_facades_v, & |
---|
705 | receive_dum_v, & |
---|
706 | buildings(nb)%kb_max - buildings(nb)%kb_min + 1, & |
---|
707 | MPI_INTEGER, & |
---|
708 | MPI_SUM, & |
---|
709 | comm2d, & |
---|
710 | ierr ) |
---|
711 | IF ( ALLOCATED( buildings(nb)%num_facade_h ) ) & !FK: Was wenn not allocated? --> s.o. |
---|
712 | buildings(nb)%num_facade_h = receive_dum_h |
---|
713 | IF ( ALLOCATED( buildings(nb)%num_facade_v ) ) & |
---|
714 | buildings(nb)%num_facade_v = receive_dum_v |
---|
715 | #else |
---|
716 | buildings(nb)%num_facade_h = num_facades_h |
---|
717 | buildings(nb)%num_facade_v = num_facades_v |
---|
718 | #endif |
---|
719 | ! |
---|
720 | !-- Deallocate dummy arrays |
---|
721 | DEALLOCATE( num_facades_h ) |
---|
722 | DEALLOCATE( num_facades_v ) |
---|
723 | DEALLOCATE( receive_dum_h ) |
---|
724 | DEALLOCATE( receive_dum_v ) |
---|
725 | ! |
---|
726 | !-- Allocate index arrays which link facade elements with surface-data type. |
---|
727 | !-- Please note, no height levels are considered here (information is stored |
---|
728 | !-- in surface-data type itself). |
---|
729 | IF ( buildings(nb)%on_pe ) THEN |
---|
730 | ! |
---|
731 | !-- Determine number of facade elements per building. |
---|
732 | buildings(nb)%num_facades_per_building_h = SUM( buildings(nb)%num_facade_h ) |
---|
733 | buildings(nb)%num_facades_per_building_v = SUM( buildings(nb)%num_facade_v ) |
---|
734 | ! |
---|
735 | !-- Allocate arrays which link the building with the horizontal and vertical |
---|
736 | !-- urban-type surfaces. Please note, linking arrays are allocated over all |
---|
737 | !-- facade elements, which is required in case a building is located at the |
---|
738 | !-- subdomain boundaries, where the building and the corresponding surface |
---|
739 | !-- elements are located on different subdomains. |
---|
740 | ALLOCATE( buildings(nb)%m_h(1:buildings(nb)%num_facades_per_building_h_l) ) |
---|
741 | |
---|
742 | ALLOCATE( buildings(nb)%l_v(1:buildings(nb)%num_facades_per_building_v_l) ) |
---|
743 | ALLOCATE( buildings(nb)%m_v(1:buildings(nb)%num_facades_per_building_v_l) ) |
---|
744 | ENDIF |
---|
745 | ! |
---|
746 | !-- Determine volume per facade element (vpf) |
---|
747 | IF ( buildings(nb)%on_pe ) THEN |
---|
748 | ALLOCATE( buildings(nb)%vpf(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
749 | |
---|
750 | DO k = buildings(nb)%kb_min, buildings(nb)%kb_max |
---|
751 | buildings(nb)%vpf(k) = buildings(nb)%volume(k) / & |
---|
752 | ( buildings(nb)%num_facade_h(k) + & |
---|
753 | buildings(nb)%num_facade_v(k) ) |
---|
754 | ENDDO |
---|
755 | ENDIF |
---|
756 | ENDDO |
---|
757 | ! |
---|
758 | !-- Link facade elements with surface data type. |
---|
759 | !-- Allocate array for counting. |
---|
760 | ALLOCATE( n_fa(1:num_build) ) |
---|
761 | n_fa = 1 |
---|
762 | |
---|
763 | DO m = 1, surf_usm_h%ns |
---|
764 | i = surf_usm_h%i(m) + surf_usm_h%ioff |
---|
765 | j = surf_usm_h%j(m) + surf_usm_h%joff |
---|
766 | |
---|
767 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM = 1 ) |
---|
768 | |
---|
769 | buildings(nb)%m_h(n_fa(nb)) = m |
---|
770 | n_fa(nb) = n_fa(nb) + 1 |
---|
771 | ENDDO |
---|
772 | |
---|
773 | n_fa = 1 |
---|
774 | DO l = 0, 3 |
---|
775 | DO m = 1, surf_usm_v(l)%ns |
---|
776 | i = surf_usm_v(l)%i(m) + surf_usm_v(l)%ioff |
---|
777 | j = surf_usm_v(l)%j(m) + surf_usm_v(l)%joff |
---|
778 | |
---|
779 | nb = MINLOC( ABS( buildings(:)%id - building_id_f%var(j,i) ), DIM = 1 ) |
---|
780 | |
---|
781 | buildings(nb)%l_v(n_fa(nb)) = l |
---|
782 | buildings(nb)%m_v(n_fa(nb)) = m |
---|
783 | n_fa(nb) = n_fa(nb) + 1 |
---|
784 | ENDDO |
---|
785 | ENDDO |
---|
786 | DEALLOCATE( n_fa ) |
---|
787 | |
---|
788 | ! |
---|
789 | !-- Building parameters by type of building. Assigned in urban_surface_mod.f90 |
---|
790 | |
---|
791 | lambda_layer3 = building_pars(63, building_type) |
---|
792 | s_layer3 = building_pars(57, building_type) |
---|
793 | f_c_win = building_pars(119, building_type) |
---|
794 | g_value_win = building_pars(120, building_type) |
---|
795 | u_value_win = building_pars(121, building_type) |
---|
796 | air_change_low = building_pars(122, building_type) |
---|
797 | air_change_high = building_pars(123, building_type) |
---|
798 | eta_ve = building_pars(124, building_type) |
---|
799 | factor_a = building_pars(125, building_type) |
---|
800 | factor_c = building_pars(126, building_type) |
---|
801 | lambda_at = building_pars(127, building_type) |
---|
802 | theta_int_h_set = building_pars(118, building_type) |
---|
803 | theta_int_c_set = building_pars(117, building_type) |
---|
804 | phi_h_max = building_pars(128, building_type) |
---|
805 | phi_c_max = building_pars(129, building_type) |
---|
806 | qint_high = building_pars(130, building_type) |
---|
807 | qint_low = building_pars(131, building_type) |
---|
808 | height_storey = building_pars(132, building_type) |
---|
809 | height_cei_con = building_pars(133, building_type) |
---|
810 | |
---|
811 | ! |
---|
812 | !-- Setting of initial room temperature [K] |
---|
813 | !-- (after first loop, use theta_m_t as theta_m_t_prev) |
---|
814 | theta_m_t_prev = initial_indoor_temperature |
---|
815 | |
---|
816 | |
---|
817 | END SUBROUTINE im_init |
---|
818 | |
---|
819 | |
---|
820 | !------------------------------------------------------------------------------! |
---|
821 | ! Description: |
---|
822 | ! ------------ |
---|
823 | !> Main part of the indoor model. |
---|
824 | !> Calculation of .... (kanani: Please describe) |
---|
825 | !------------------------------------------------------------------------------! |
---|
826 | SUBROUTINE im_main_heatcool |
---|
827 | |
---|
828 | USE arrays_3d, & |
---|
829 | ONLY: ddzw, dzw |
---|
830 | |
---|
831 | USE basic_constants_and_equations_mod, & |
---|
832 | ONLY: c_p |
---|
833 | |
---|
834 | USE control_parameters, & |
---|
835 | ONLY: rho_surface |
---|
836 | |
---|
837 | USE date_and_time_mod, & |
---|
838 | ONLY: time_utc |
---|
839 | |
---|
840 | USE grid_variables, & |
---|
841 | ONLY: dx, dy |
---|
842 | |
---|
843 | USE pegrid |
---|
844 | |
---|
845 | USE surface_mod, & |
---|
846 | ONLY: ind_veg_wall, ind_wat_win, surf_usm_h, surf_usm_v |
---|
847 | |
---|
848 | USE urban_surface_mod, & |
---|
849 | ONLY: nzt_wall, t_wall_h, t_wall_v, t_window_h, t_window_v, & |
---|
850 | building_type |
---|
851 | |
---|
852 | |
---|
853 | IMPLICIT NONE |
---|
854 | |
---|
855 | INTEGER(iwp) :: i !< index of facade-adjacent atmosphere grid point in x-direction |
---|
856 | INTEGER(iwp) :: j !< index of facade-adjacent atmosphere grid point in y-direction |
---|
857 | INTEGER(iwp) :: k !< index of facade-adjacent atmosphere grid point in z-direction |
---|
858 | INTEGER(iwp) :: kk !< vertical index of indoor grid point adjacent to facade |
---|
859 | INTEGER(iwp) :: l !< running index for surface-element orientation |
---|
860 | INTEGER(iwp) :: m !< running index surface elements |
---|
861 | INTEGER(iwp) :: nb !< running index for buildings |
---|
862 | INTEGER(iwp) :: fa !< running index for facade elements of each building |
---|
863 | |
---|
864 | REAL(wp) :: indoor_wall_window_temperature !< weighted temperature of innermost wall/window layer |
---|
865 | REAL(wp) :: near_facade_temperature !< outside air temperature 10cm away from facade |
---|
866 | REAL(wp) :: time_utc_hour !< time of day (hour UTC) |
---|
867 | |
---|
868 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in_l_send !< dummy send buffer used for summing-up indoor temperature per kk-level |
---|
869 | REAL(wp), DIMENSION(:), ALLOCATABLE :: t_in_recv !< dummy recv buffer used for summing-up indoor temperature per kk-level |
---|
870 | |
---|
871 | ! |
---|
872 | !-- Daily schedule, here for 08:00-18:00 = 1, other hours = 0. |
---|
873 | !-- time_utc_hour is calculated here based on time_utc [s] from |
---|
874 | !-- date_and_time_mod. |
---|
875 | !-- (kanani: Does this schedule not depend on if it's an office or resident |
---|
876 | !-- building?) |
---|
877 | time_utc_hour = time_utc / 3600.0_wp |
---|
878 | |
---|
879 | ! |
---|
880 | !-- Allocation of the load profiles to the building types |
---|
881 | !-- Residental Building, panel WBS 70 |
---|
882 | if (building_type == 1 .OR. & |
---|
883 | building_type == 2 .OR. & |
---|
884 | building_type == 3 .OR. & |
---|
885 | building_type == 10 .OR. & |
---|
886 | building_type == 11 .OR. & |
---|
887 | building_type == 12) then |
---|
888 | ventilation_int_loads = 1 |
---|
889 | !-- Office, building with large windows |
---|
890 | else if (building_type == 4 .OR. & |
---|
891 | building_type == 5 .OR. & |
---|
892 | building_type == 6 .OR. & |
---|
893 | building_type == 7 .OR. & |
---|
894 | building_type == 8 .OR. & |
---|
895 | building_type == 9) then |
---|
896 | ventilation_int_loads = 2 |
---|
897 | !-- Industry, hospitals |
---|
898 | else if (building_type == 13 .OR. & |
---|
899 | building_type == 14 .OR. & |
---|
900 | building_type == 15 .OR. & |
---|
901 | building_type == 16 .OR. & |
---|
902 | building_type == 17 .OR. & |
---|
903 | building_type == 18) then |
---|
904 | ventilation_int_loads = 3 |
---|
905 | |
---|
906 | end if |
---|
907 | |
---|
908 | !-- Residental Building, panel WBS 70 |
---|
909 | |
---|
910 | if (ventilation_int_loads == 1) THEN |
---|
911 | if ( time_utc_hour >= 6.0_wp .AND. time_utc_hour <= 8.0_wp ) THEN |
---|
912 | schedule_d = 1 |
---|
913 | else if ( time_utc_hour >= 18.0_wp .AND. time_utc_hour <= 23.0_wp ) THEN |
---|
914 | schedule_d = 1 |
---|
915 | else |
---|
916 | schedule_d = 0 |
---|
917 | end if |
---|
918 | end if |
---|
919 | |
---|
920 | !-- Office, building with large windows |
---|
921 | |
---|
922 | if (ventilation_int_loads == 2) THEN |
---|
923 | if ( time_utc_hour >= 8.0_wp .AND. time_utc_hour <= 18.0_wp ) THEN |
---|
924 | schedule_d = 1 |
---|
925 | else |
---|
926 | schedule_d = 0 |
---|
927 | end if |
---|
928 | end if |
---|
929 | |
---|
930 | !-- Industry, hospitals |
---|
931 | if (ventilation_int_loads == 3) THEN |
---|
932 | if ( time_utc_hour >= 6.0_wp .AND. time_utc_hour <= 22.0_wp ) THEN |
---|
933 | schedule_d = 1 |
---|
934 | else |
---|
935 | schedule_d = 0 |
---|
936 | end if |
---|
937 | end if |
---|
938 | |
---|
939 | |
---|
940 | ! |
---|
941 | !-- Following calculations must be done for each facade element. |
---|
942 | DO nb = 1, num_build |
---|
943 | ! |
---|
944 | !-- First, check whether building is present on local subdomain. |
---|
945 | IF ( buildings(nb)%on_pe ) THEN |
---|
946 | ! |
---|
947 | !-- Initialize/reset indoor temperature |
---|
948 | buildings(nb)%t_in = 0.0_wp |
---|
949 | buildings(nb)%t_in_l = 0.0_wp |
---|
950 | ! |
---|
951 | !-- Horizontal surfaces |
---|
952 | DO fa = 1, buildings(nb)%num_facades_per_building_h_l |
---|
953 | ! |
---|
954 | !-- Determine index where corresponding surface-type information |
---|
955 | !-- is stored. |
---|
956 | m = buildings(nb)%m_h(fa) |
---|
957 | ! |
---|
958 | !-- Determine building height level index. |
---|
959 | kk = surf_usm_h%k(m) + surf_usm_h%koff |
---|
960 | ! |
---|
961 | !-- Building geometries --> not time-dependent |
---|
962 | facade_element_area = dx * dy !< [m2] surface area per facade element |
---|
963 | floor_area_per_facade = buildings(nb)%vpf(kk) * ddzw(kk) !< [m2] net floor area per facade element |
---|
964 | indoor_volume_per_facade = buildings(nb)%vpf(kk) !< [m3] indoor air volume per facade element |
---|
965 | window_area_per_facade = surf_usm_h%frac(ind_wat_win,m) * facade_element_area !< [m2] window area per facade element |
---|
966 | eff_mass_area = factor_a * floor_area_per_facade !< [m2] standard values according to Table 12 section 12.3.1.2 (calculate over Eq. (65) according to section 12.3.1.2) |
---|
967 | c_m = factor_c * floor_area_per_facade !< [J/K] standard values according to table 12 section 12.3.1.2 (calculate over Eq. (66) according to section 12.3.1.2) |
---|
968 | total_area = lambda_at * floor_area_per_facade !< [m2] area of all surfaces pointing to zone Eq. (9) according to section 7.2.2.2 |
---|
969 | |
---|
970 | !-- Calculation of heat transfer coefficient for transmission --> not time-dependent |
---|
971 | h_tr_w = window_area_per_facade * u_value_win !< [W/K] only for windows |
---|
972 | h_tr_is = total_area * h_is !< [W/K] with h_is = 3.45 W / (m2 K) between surface and air, Eq. (9) |
---|
973 | h_tr_ms = eff_mass_area * h_ms !< [W/K] with h_ms = 9.10 W / (m2 K) between component and surface, Eq. (64) |
---|
974 | h_tr_op = 1 / ( 1 / ( ( facade_element_area - window_area_per_facade ) & |
---|
975 | * lambda_layer3 / s_layer3 * 0.5 ) + 1 / h_tr_ms ) |
---|
976 | h_tr_em = 1 / ( 1 / h_tr_op - 1 / h_tr_ms ) !< [W/K] Eq. (63), Section 12.2.2 |
---|
977 | ! |
---|
978 | !-- internal air loads dependent on the occupacy of the room |
---|
979 | !-- basical internal heat gains (qint_low) with additional internal heat gains by occupancy (qint_high) (0,5*phi_int) |
---|
980 | phi_ia = 0.5 * ( ( qint_high * schedule_d + qint_low ) & |
---|
981 | * floor_area_per_facade ) !< [W] Eq. (C.1) |
---|
982 | ! |
---|
983 | !-- Airflow dependent on the occupacy of the room |
---|
984 | !-- basical airflow (air_change_low) with additional airflow gains by occupancy (air_change_high) |
---|
985 | air_change = ( air_change_high * schedule_d + air_change_low ) !< [1/h]? |
---|
986 | ! |
---|
987 | !-- Heat transfer of ventilation |
---|
988 | !-- not less than 0.01 W/K to provide division by 0 in further calculations |
---|
989 | !-- with heat capacity of air 0.33 Wh/m2K |
---|
990 | h_ve = MAX( 0.01_wp , ( air_change * indoor_volume_per_facade * & |
---|
991 | 0.33_wp * (1 - eta_ve ) ) ) !< [W/K] from ISO 13789 Eq.(10) |
---|
992 | |
---|
993 | !-- Heat transfer coefficient auxiliary variables |
---|
994 | h_tr_1 = 1 / ( ( 1 / h_ve ) + ( 1 / h_tr_is ) ) !< [W/K] Eq. (C.6) |
---|
995 | h_tr_2 = h_tr_1 + h_tr_w !< [W/K] Eq. (C.7) |
---|
996 | h_tr_3 = 1 / ( ( 1 / h_tr_2 ) + ( 1 / h_tr_ms ) ) !< [W/K] Eq. (C.8) |
---|
997 | ! |
---|
998 | !-- Net short-wave radiation through window area (was i_global) |
---|
999 | net_sw_in = surf_usm_h%rad_sw_in(m) - surf_usm_h%rad_sw_out(m) |
---|
1000 | ! |
---|
1001 | !-- Quantities needed for im_calc_temperatures |
---|
1002 | i = surf_usm_h%i(m) |
---|
1003 | j = surf_usm_h%j(m) |
---|
1004 | k = surf_usm_h%k(m) |
---|
1005 | near_facade_temperature = surf_usm_h%pt_10cm(m) |
---|
1006 | indoor_wall_window_temperature = & |
---|
1007 | surf_usm_h%frac(ind_veg_wall,m) * t_wall_h(nzt_wall,m) & |
---|
1008 | + surf_usm_h%frac(ind_wat_win,m) * t_window_h(nzt_wall,m) |
---|
1009 | ! |
---|
1010 | !-- Solar thermal gains. If net_sw_in larger than sun-protection |
---|
1011 | !-- threshold parameter (params_solar_protection), sun protection will |
---|
1012 | !-- be activated |
---|
1013 | IF ( net_sw_in <= params_solar_protection ) THEN |
---|
1014 | solar_protection_off = 1 |
---|
1015 | solar_protection_on = 0 |
---|
1016 | ELSE |
---|
1017 | solar_protection_off = 0 |
---|
1018 | solar_protection_on = 1 |
---|
1019 | ENDIF |
---|
1020 | ! |
---|
1021 | !-- Calculation of total heat gains from net_sw_in through windows [W] in respect on automatic sun protection |
---|
1022 | !-- DIN 4108 - 2 chap.8 |
---|
1023 | phi_sol = ( window_area_per_facade * net_sw_in * solar_protection_off & |
---|
1024 | + window_area_per_facade * net_sw_in * f_c_win * solar_protection_on ) & |
---|
1025 | * g_value_win * ( 1 - params_f_f ) * params_f_w !< [W] |
---|
1026 | ! |
---|
1027 | !-- Calculation of the mass specific thermal load for internal and external heatsources of the inner node |
---|
1028 | phi_m = (eff_mass_area / total_area) * ( phi_ia + phi_sol ) !< [W] Eq. (C.2) with phi_ia=0,5*phi_int |
---|
1029 | ! |
---|
1030 | !-- Calculation mass specific thermal load implied non thermal mass |
---|
1031 | phi_st = ( 1 - ( eff_mass_area / total_area ) - ( h_tr_w / ( 9.1 * total_area ) ) ) & |
---|
1032 | * ( phi_ia + phi_sol ) !< [W] Eq. (C.3) with phi_ia=0,5*phi_int |
---|
1033 | ! |
---|
1034 | !-- Calculations for deriving indoor temperature and heat flux into the wall |
---|
1035 | !-- Step 1: Indoor temperature without heating and cooling |
---|
1036 | !-- section C.4.1 Picture C.2 zone 3) |
---|
1037 | phi_hc_nd = 0 |
---|
1038 | |
---|
1039 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1040 | near_facade_temperature, phi_hc_nd ) |
---|
1041 | ! |
---|
1042 | !-- If air temperature between border temperatures of heating and cooling, assign output variable, then ready |
---|
1043 | IF ( theta_int_h_set <= theta_air .AND. theta_air <= theta_int_c_set ) THEN |
---|
1044 | phi_hc_nd_ac = 0 |
---|
1045 | phi_hc_nd = phi_hc_nd_ac |
---|
1046 | theta_air_ac = theta_air |
---|
1047 | ! |
---|
1048 | !-- Step 2: Else, apply 10 W/m² heating/cooling power and calculate indoor temperature |
---|
1049 | !-- again. |
---|
1050 | ELSE |
---|
1051 | ! |
---|
1052 | !-- Temperature not correct, calculation method according to section C4.2 |
---|
1053 | theta_air_0 = theta_air !< Note temperature without heating/cooling |
---|
1054 | |
---|
1055 | !-- Heating or cooling? |
---|
1056 | IF ( theta_air > theta_int_c_set ) THEN |
---|
1057 | theta_air_set = theta_int_c_set |
---|
1058 | ELSE |
---|
1059 | theta_air_set = theta_int_h_set |
---|
1060 | ENDIF |
---|
1061 | |
---|
1062 | !-- Calculate the temperature with phi_hc_nd_10 |
---|
1063 | phi_hc_nd_10 = 10.0_wp * floor_area_per_facade |
---|
1064 | phi_hc_nd = phi_hc_nd_10 |
---|
1065 | |
---|
1066 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1067 | near_facade_temperature, phi_hc_nd ) |
---|
1068 | |
---|
1069 | theta_air_10 = theta_air !< Note the temperature with 10 W/m2 of heating |
---|
1070 | ! |
---|
1071 | |
---|
1072 | phi_hc_nd_un = phi_hc_nd_10 * (theta_air_set - theta_air_0) & |
---|
1073 | / (theta_air_10 - theta_air_0) !< Eq. (C.13) |
---|
1074 | |
---|
1075 | |
---|
1076 | |
---|
1077 | !-- Step 3: With temperature ratio to determine the heating or cooling capacity |
---|
1078 | !-- If necessary, limit the power to maximum power |
---|
1079 | !-- section C.4.1 Picture C.2 zone 2) and 4) |
---|
1080 | IF ( phi_c_max < phi_hc_nd_un .AND. phi_hc_nd_un < phi_h_max ) THEN |
---|
1081 | phi_hc_nd_ac = phi_hc_nd_un |
---|
1082 | phi_hc_nd = phi_hc_nd_un |
---|
1083 | ELSE |
---|
1084 | !-- Step 4: Inner temperature with maximum heating (phi_hc_nd_un positive) or cooling (phi_hc_nd_un negative) |
---|
1085 | !-- section C.4.1 Picture C.2 zone 1) and 5) |
---|
1086 | IF ( phi_hc_nd_un > 0 ) THEN |
---|
1087 | phi_hc_nd_ac = phi_h_max !< Limit heating |
---|
1088 | ELSE |
---|
1089 | phi_hc_nd_ac = phi_c_max !< Limit cooling |
---|
1090 | ENDIF |
---|
1091 | ENDIF |
---|
1092 | |
---|
1093 | phi_hc_nd = phi_hc_nd_ac |
---|
1094 | ! |
---|
1095 | !-- Calculate the temperature with phi_hc_nd_ac (new) |
---|
1096 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1097 | near_facade_temperature, phi_hc_nd ) |
---|
1098 | |
---|
1099 | theta_air_ac = theta_air |
---|
1100 | |
---|
1101 | ENDIF |
---|
1102 | ! |
---|
1103 | !-- Update theta_m_t_prev |
---|
1104 | theta_m_t_prev = theta_m_t |
---|
1105 | ! |
---|
1106 | !-- Calculate the operating temperature with weighted mean temperature of air and mean solar temperature |
---|
1107 | !-- Will be used for thermal comfort calculations |
---|
1108 | theta_op = 0.3 * theta_air_ac + 0.7 * theta_s !< [degree_C] operative Temperature Eq. (C.12) |
---|
1109 | ! |
---|
1110 | !-- Heat flux into the wall. Value needed in urban_surface_mod to |
---|
1111 | !-- calculate heat transfer through wall layers towards the facade |
---|
1112 | !-- (use c_p * rho_surface to convert [W/m2] into [K m/s]) |
---|
1113 | q_wall_win = h_tr_ms * ( theta_s - theta_m ) & |
---|
1114 | / ( facade_element_area & |
---|
1115 | - window_area_per_facade ) |
---|
1116 | ! |
---|
1117 | !-- Transfer q_wall_win back to USM (innermost wall/window layer) |
---|
1118 | surf_usm_h%iwghf_eb(m) = q_wall_win |
---|
1119 | surf_usm_h%iwghf_eb_window(m) = q_wall_win |
---|
1120 | ! |
---|
1121 | !-- Sum up operational indoor temperature per kk-level. Further below, |
---|
1122 | !-- this temperature is reduced by MPI to one temperature per kk-level |
---|
1123 | !-- and building (processor overlapping) |
---|
1124 | buildings(nb)%t_in_l(kk) = buildings(nb)%t_in_l(kk) + theta_op |
---|
1125 | ! |
---|
1126 | !-- Calculation of waste heat |
---|
1127 | !-- Anthropogenic heat output |
---|
1128 | IF ( phi_hc_nd_ac > 0 ) THEN |
---|
1129 | heating_on = 1 |
---|
1130 | cooling_on = 0 |
---|
1131 | ELSE |
---|
1132 | heating_on = 0 |
---|
1133 | cooling_on = 1 |
---|
1134 | ENDIF |
---|
1135 | |
---|
1136 | q_waste_heat = (phi_hc_nd * (params_waste_heat_h * heating_on + params_waste_heat_c * cooling_on)) !< [W/m2] anthropogenic heat output |
---|
1137 | ! surf_usm_h%shf(m)=q_waste_heat |
---|
1138 | |
---|
1139 | ENDDO !< Horizontal surfaces loop |
---|
1140 | ! |
---|
1141 | !-- Vertical surfaces |
---|
1142 | DO fa = 1, buildings(nb)%num_facades_per_building_v_l |
---|
1143 | ! |
---|
1144 | !-- Determine indices where corresponding surface-type information |
---|
1145 | !-- is stored. |
---|
1146 | l = buildings(nb)%l_v(fa) |
---|
1147 | m = buildings(nb)%m_v(fa) |
---|
1148 | ! |
---|
1149 | !-- Determine building height level index. |
---|
1150 | kk = surf_usm_v(l)%k(m) + surf_usm_v(l)%koff |
---|
1151 | ! |
---|
1152 | !-- Building geometries --> not time-dependent |
---|
1153 | IF ( l == 0 .OR. l == 1 ) facade_element_area = dx * dzw(kk) !< [m2] surface area per facade element |
---|
1154 | IF ( l == 2 .OR. l == 3 ) facade_element_area = dy * dzw(kk) !< [m2] surface area per facade element |
---|
1155 | floor_area_per_facade = buildings(nb)%vpf(kk) * ddzw(kk) !< [m2] net floor area per facade element |
---|
1156 | indoor_volume_per_facade = buildings(nb)%vpf(kk) !< [m3] indoor air volume per facade element |
---|
1157 | window_area_per_facade = surf_usm_v(l)%frac(ind_wat_win,m) * facade_element_area !< [m2] window area per facade element |
---|
1158 | eff_mass_area = factor_a * floor_area_per_facade !< [m2] standard values according to Table 12 section 12.3.1.2 (calculate over Eq. (65) according to section 12.3.1.2) |
---|
1159 | c_m = factor_c * floor_area_per_facade !< [J/K] standard values according to table 12 section 12.3.1.2 (calculate over Eq. (66) according to section 12.3.1.2) |
---|
1160 | total_area = lambda_at * floor_area_per_facade !< [m2] area of all surfaces pointing to zone Eq. (9) according to section 7.2.2.2 |
---|
1161 | ! |
---|
1162 | !-- Calculation of heat transfer coefficient for transmission --> not time-dependent |
---|
1163 | h_tr_w = window_area_per_facade * u_value_win !< [W/K] only for windows |
---|
1164 | h_tr_is = total_area * h_is !< [W/K] with h_is = 3.45 W / (m2 K) between surface and air, Eq. (9) |
---|
1165 | h_tr_ms = eff_mass_area * h_ms !< [W/K] with h_ms = 9.10 W / (m2 K) between component and surface, Eq. (64) |
---|
1166 | h_tr_op = 1 / ( 1 / ( ( facade_element_area - window_area_per_facade ) & |
---|
1167 | * lambda_layer3 / s_layer3 * 0.5 ) + 1 / h_tr_ms ) |
---|
1168 | h_tr_em = 1 / ( 1 / h_tr_op - 1 / h_tr_ms ) !< [W/K] Eq. (63), Section 12.2.2 |
---|
1169 | ! |
---|
1170 | !-- internal air loads dependent on the occupacy of the room |
---|
1171 | !-- basical internal heat gains (qint_low) with additional internal heat gains by occupancy (qint_high) (0,5*phi_int) |
---|
1172 | phi_ia = 0.5 * ( ( qint_high * schedule_d + qint_low ) & |
---|
1173 | * floor_area_per_facade ) !< [W] Eq. (C.1) |
---|
1174 | ! |
---|
1175 | !-- Airflow dependent on the occupacy of the room |
---|
1176 | !-- basical airflow (air_change_low) with additional airflow gains by occupancy (air_change_high) |
---|
1177 | air_change = ( air_change_high * schedule_d + air_change_low ) |
---|
1178 | ! |
---|
1179 | !-- Heat transfer of ventilation |
---|
1180 | !-- not less than 0.01 W/K to provide division by 0 in further calculations |
---|
1181 | !-- with heat capacity of air 0.33 Wh/m2K |
---|
1182 | h_ve = MAX( 0.01_wp , ( air_change * indoor_volume_per_facade * & |
---|
1183 | 0.33_wp * (1 - eta_ve ) ) ) !< [W/K] from ISO 13789 Eq.(10) |
---|
1184 | |
---|
1185 | !-- Heat transfer coefficient auxiliary variables |
---|
1186 | h_tr_1 = 1 / ( ( 1 / h_ve ) + ( 1 / h_tr_is ) ) !< [W/K] Eq. (C.6) |
---|
1187 | h_tr_2 = h_tr_1 + h_tr_w !< [W/K] Eq. (C.7) |
---|
1188 | h_tr_3 = 1 / ( ( 1 / h_tr_2 ) + ( 1 / h_tr_ms ) ) !< [W/K] Eq. (C.8) |
---|
1189 | ! |
---|
1190 | !-- Net short-wave radiation through window area (was i_global) |
---|
1191 | net_sw_in = surf_usm_v(l)%rad_sw_in(m) - surf_usm_v(l)%rad_sw_out(m) |
---|
1192 | ! |
---|
1193 | !-- Quantities needed for im_calc_temperatures |
---|
1194 | i = surf_usm_v(l)%i(m) |
---|
1195 | j = surf_usm_v(l)%j(m) |
---|
1196 | k = surf_usm_v(l)%k(m) |
---|
1197 | near_facade_temperature = surf_usm_v(l)%pt_10cm(m) |
---|
1198 | indoor_wall_window_temperature = & |
---|
1199 | surf_usm_v(l)%frac(ind_veg_wall,m) * t_wall_v(l)%t(nzt_wall,m) & |
---|
1200 | + surf_usm_v(l)%frac(ind_wat_win,m) * t_window_v(l)%t(nzt_wall,m) |
---|
1201 | ! |
---|
1202 | !-- Solar thermal gains. If net_sw_in larger than sun-protection |
---|
1203 | !-- threshold parameter (params_solar_protection), sun protection will |
---|
1204 | !-- be activated |
---|
1205 | IF ( net_sw_in <= params_solar_protection ) THEN |
---|
1206 | solar_protection_off = 1 |
---|
1207 | solar_protection_on = 0 |
---|
1208 | ELSE |
---|
1209 | solar_protection_off = 0 |
---|
1210 | solar_protection_on = 1 |
---|
1211 | ENDIF |
---|
1212 | ! |
---|
1213 | !-- Calculation of total heat gains from net_sw_in through windows [W] in respect on automatic sun protection |
---|
1214 | !-- DIN 4108 - 2 chap.8 |
---|
1215 | phi_sol = ( window_area_per_facade * net_sw_in * solar_protection_off & |
---|
1216 | + window_area_per_facade * net_sw_in * f_c_win * solar_protection_on ) & |
---|
1217 | * g_value_win * ( 1 - params_f_f ) * params_f_w |
---|
1218 | ! |
---|
1219 | !-- Calculation of the mass specific thermal load for internal and external heatsources |
---|
1220 | phi_m = (eff_mass_area / total_area) * ( phi_ia + phi_sol ) !< [W] Eq. (C.2) with phi_ia=0,5*phi_int |
---|
1221 | ! |
---|
1222 | !-- Calculation mass specific thermal load implied non thermal mass |
---|
1223 | phi_st = ( 1 - ( eff_mass_area / total_area ) - ( h_tr_w / ( 9.1 * total_area ) ) ) & |
---|
1224 | * ( phi_ia + phi_sol ) !< [W] Eq. (C.3) with phi_ia=0,5*phi_int |
---|
1225 | ! |
---|
1226 | !-- Calculations for deriving indoor temperature and heat flux into the wall |
---|
1227 | !-- Step 1: Indoor temperature without heating and cooling |
---|
1228 | !-- section C.4.1 Picture C.2 zone 3) |
---|
1229 | phi_hc_nd = 0 |
---|
1230 | |
---|
1231 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1232 | near_facade_temperature, phi_hc_nd ) |
---|
1233 | ! |
---|
1234 | !-- If air temperature between border temperatures of heating and cooling, assign output variable, then ready |
---|
1235 | IF ( theta_int_h_set <= theta_air .AND. theta_air <= theta_int_c_set ) THEN |
---|
1236 | phi_hc_nd_ac = 0 |
---|
1237 | phi_hc_nd = phi_hc_nd_ac |
---|
1238 | theta_air_ac = theta_air |
---|
1239 | ! |
---|
1240 | !-- Step 2: Else, apply 10 W/m² heating/cooling power and calculate indoor temperature |
---|
1241 | !-- again. |
---|
1242 | ELSE |
---|
1243 | ! |
---|
1244 | !-- Temperature not correct, calculation method according to section C4.2 |
---|
1245 | theta_air_0 = theta_air !< Note temperature without heating/cooling |
---|
1246 | |
---|
1247 | !-- Heating or cooling? |
---|
1248 | IF ( theta_air > theta_int_c_set ) THEN |
---|
1249 | theta_air_set = theta_int_c_set |
---|
1250 | ELSE |
---|
1251 | theta_air_set = theta_int_h_set |
---|
1252 | ENDIF |
---|
1253 | |
---|
1254 | !-- Calculate the temperature with phi_hc_nd_10 |
---|
1255 | phi_hc_nd_10 = 10.0_wp * floor_area_per_facade |
---|
1256 | phi_hc_nd = phi_hc_nd_10 |
---|
1257 | |
---|
1258 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1259 | near_facade_temperature, phi_hc_nd ) |
---|
1260 | |
---|
1261 | theta_air_10 = theta_air !< Note the temperature with 10 W/m2 of heating |
---|
1262 | |
---|
1263 | |
---|
1264 | phi_hc_nd_un = phi_hc_nd_10 * (theta_air_set - theta_air_0) & |
---|
1265 | / (theta_air_10 - theta_air_0) !< Eq. (C.13) |
---|
1266 | ! |
---|
1267 | !-- Step 3: With temperature ratio to determine the heating or cooling capacity |
---|
1268 | !-- If necessary, limit the power to maximum power |
---|
1269 | !-- section C.4.1 Picture C.2 zone 2) and 4) |
---|
1270 | IF ( phi_c_max < phi_hc_nd_un .AND. phi_hc_nd_un < phi_h_max ) THEN |
---|
1271 | phi_hc_nd_ac = phi_hc_nd_un |
---|
1272 | phi_hc_nd = phi_hc_nd_un |
---|
1273 | ELSE |
---|
1274 | !-- Step 4: Inner temperature with maximum heating (phi_hc_nd_un positive) or cooling (phi_hc_nd_un negative) |
---|
1275 | !-- section C.4.1 Picture C.2 zone 1) and 5) |
---|
1276 | IF ( phi_hc_nd_un > 0 ) THEN |
---|
1277 | phi_hc_nd_ac = phi_h_max !< Limit heating |
---|
1278 | ELSE |
---|
1279 | phi_hc_nd_ac = phi_c_max !< Limit cooling |
---|
1280 | ENDIF |
---|
1281 | ENDIF |
---|
1282 | |
---|
1283 | phi_hc_nd = phi_hc_nd_ac |
---|
1284 | ! |
---|
1285 | !-- Calculate the temperature with phi_hc_nd_ac (new) |
---|
1286 | CALL im_calc_temperatures ( i, j, k, indoor_wall_window_temperature, & |
---|
1287 | near_facade_temperature, phi_hc_nd ) |
---|
1288 | |
---|
1289 | theta_air_ac = theta_air |
---|
1290 | |
---|
1291 | ENDIF |
---|
1292 | ! |
---|
1293 | !-- Update theta_m_t_prev |
---|
1294 | theta_m_t_prev = theta_m_t |
---|
1295 | ! |
---|
1296 | !-- Calculate the operating temperature with weighted mean of temperature of air and mean |
---|
1297 | !-- Will be used for thermal comfort calculations |
---|
1298 | theta_op = 0.3 * theta_air_ac + 0.7 * theta_s |
---|
1299 | ! |
---|
1300 | !-- Heat flux into the wall. Value needed in urban_surface_mod to |
---|
1301 | !-- calculate heat transfer through wall layers towards the facade |
---|
1302 | q_wall_win = h_tr_ms * ( theta_s - theta_m ) & |
---|
1303 | / ( facade_element_area & |
---|
1304 | - window_area_per_facade ) |
---|
1305 | ! |
---|
1306 | !-- Transfer q_wall_win back to USM (innermost wall/window layer) |
---|
1307 | surf_usm_v(l)%iwghf_eb(m) = q_wall_win |
---|
1308 | surf_usm_v(l)%iwghf_eb_window(m) = q_wall_win |
---|
1309 | ! |
---|
1310 | !-- Sum up operational indoor temperature per kk-level. Further below, |
---|
1311 | !-- this temperature is reduced by MPI to one temperature per kk-level |
---|
1312 | !-- and building (processor overlapping) |
---|
1313 | buildings(nb)%t_in_l(kk) = buildings(nb)%t_in_l(kk) + theta_op |
---|
1314 | |
---|
1315 | ! |
---|
1316 | !-- Calculation of waste heat |
---|
1317 | !-- Anthropogenic heat output |
---|
1318 | IF ( phi_hc_nd_ac > 0 ) THEN |
---|
1319 | heating_on = 1 |
---|
1320 | cooling_on = 0 |
---|
1321 | ELSE |
---|
1322 | heating_on = 0 |
---|
1323 | cooling_on = 1 |
---|
1324 | ENDIF |
---|
1325 | |
---|
1326 | q_waste_heat = (phi_hc_nd * (params_waste_heat_h * heating_on + params_waste_heat_c * cooling_on)) !< [W/m2] , anthropogenic heat output |
---|
1327 | ! surf_usm_v(l)%waste_heat(m)=q_waste_heat |
---|
1328 | |
---|
1329 | ENDDO !< Vertical surfaces loop |
---|
1330 | |
---|
1331 | ENDIF !< buildings(nb)%on_pe |
---|
1332 | ENDDO !< buildings loop |
---|
1333 | |
---|
1334 | ! |
---|
1335 | !-- Determine total number of facade elements per building and assign number to |
---|
1336 | !-- building data type. |
---|
1337 | DO nb = 1, num_build |
---|
1338 | ! |
---|
1339 | !-- Allocate dummy array used for summing-up facade elements. |
---|
1340 | !-- Please note, dummy arguments are necessary as building-date type |
---|
1341 | !-- arrays are not necessarily allocated on all PEs. |
---|
1342 | ALLOCATE( t_in_l_send(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
1343 | ALLOCATE( t_in_recv(buildings(nb)%kb_min:buildings(nb)%kb_max) ) |
---|
1344 | t_in_l_send = 0.0_wp |
---|
1345 | t_in_recv = 0.0_wp |
---|
1346 | |
---|
1347 | IF ( buildings(nb)%on_pe ) THEN |
---|
1348 | t_in_l_send = buildings(nb)%t_in_l |
---|
1349 | ENDIF |
---|
1350 | |
---|
1351 | #if defined( __parallel ) |
---|
1352 | CALL MPI_ALLREDUCE( t_in_l_send, & |
---|
1353 | t_in_recv, & |
---|
1354 | buildings(nb)%kb_max - buildings(nb)%kb_min + 1, & |
---|
1355 | MPI_REAL, & |
---|
1356 | MPI_SUM, & |
---|
1357 | comm2d, & |
---|
1358 | ierr ) |
---|
1359 | |
---|
1360 | IF ( ALLOCATED( buildings(nb)%t_in ) ) & |
---|
1361 | buildings(nb)%t_in = t_in_recv |
---|
1362 | #else |
---|
1363 | buildings(nb)%t_in = buildings(nb)%t_in_l |
---|
1364 | #endif |
---|
1365 | |
---|
1366 | buildings(nb)%t_in = buildings(nb)%t_in / & |
---|
1367 | ( buildings(nb)%num_facade_h + & |
---|
1368 | buildings(nb)%num_facade_v ) |
---|
1369 | ! |
---|
1370 | !-- Deallocate dummy arrays |
---|
1371 | DEALLOCATE( t_in_l_send ) |
---|
1372 | DEALLOCATE( t_in_recv ) |
---|
1373 | |
---|
1374 | ENDDO |
---|
1375 | |
---|
1376 | |
---|
1377 | END SUBROUTINE im_main_heatcool |
---|
1378 | |
---|
1379 | !------------------------------------------------------------------------------! |
---|
1380 | ! Description: |
---|
1381 | ! ------------ |
---|
1382 | !> Parin for &indoor_parameters for indoor model |
---|
1383 | !------------------------------------------------------------------------------! |
---|
1384 | SUBROUTINE im_parin |
---|
1385 | |
---|
1386 | USE control_parameters, & |
---|
1387 | ONLY: indoor_model |
---|
1388 | |
---|
1389 | IMPLICIT NONE |
---|
1390 | |
---|
1391 | CHARACTER (LEN=80) :: line !< string containing current line of file PARIN |
---|
1392 | |
---|
1393 | |
---|
1394 | |
---|
1395 | NAMELIST /indoor_parameters/ building_type, dt_indoor, & |
---|
1396 | initial_indoor_temperature |
---|
1397 | |
---|
1398 | ! line = ' ' |
---|
1399 | |
---|
1400 | ! |
---|
1401 | !-- Try to find indoor model package |
---|
1402 | REWIND ( 11 ) |
---|
1403 | line = ' ' |
---|
1404 | DO WHILE ( INDEX( line, '&indoor_parameters' ) == 0 ) |
---|
1405 | READ ( 11, '(A)', END=10 ) line |
---|
1406 | ! PRINT*, 'line: ', line |
---|
1407 | ENDDO |
---|
1408 | BACKSPACE ( 11 ) |
---|
1409 | |
---|
1410 | ! |
---|
1411 | !-- Read user-defined namelist |
---|
1412 | READ ( 11, indoor_parameters ) |
---|
1413 | ! |
---|
1414 | !-- Set flag that indicates that the indoor model is switched on |
---|
1415 | indoor_model = .TRUE. |
---|
1416 | |
---|
1417 | ! |
---|
1418 | !-- Activate spinup (maybe later |
---|
1419 | ! IF ( spinup_time > 0.0_wp ) THEN |
---|
1420 | ! coupling_start_time = spinup_time |
---|
1421 | ! end_time = end_time + spinup_time |
---|
1422 | ! IF ( spinup_pt_mean == 9999999.9_wp ) THEN |
---|
1423 | ! spinup_pt_mean = pt_surface |
---|
1424 | ! ENDIF |
---|
1425 | ! spinup = .TRUE. |
---|
1426 | ! ENDIF |
---|
1427 | |
---|
1428 | 10 CONTINUE |
---|
1429 | |
---|
1430 | END SUBROUTINE im_parin |
---|
1431 | |
---|
1432 | |
---|
1433 | END MODULE indoor_model_mod |
---|