1 | SUBROUTINE calc_liquid_water_content |
---|
2 | |
---|
3 | !------------------------------------------------------------------------------! |
---|
4 | ! Actual revisions: |
---|
5 | ! ----------------- |
---|
6 | ! |
---|
7 | ! |
---|
8 | ! Former revisions: |
---|
9 | ! ----------------- |
---|
10 | ! $Id: calc_liquid_water_content.f90 98 2007-06-21 09:36:33Z maronga $ |
---|
11 | ! |
---|
12 | ! 95 2007-06-02 16:48:38Z raasch |
---|
13 | ! hydro_press renamed hyp |
---|
14 | ! |
---|
15 | ! 19 2007-02-23 04:53:48Z raasch |
---|
16 | ! Old comment removed |
---|
17 | ! |
---|
18 | ! RCS Log replace by Id keyword, revision history cleaned up |
---|
19 | ! |
---|
20 | ! Revision 1.5 2005/03/26 15:22:06 raasch |
---|
21 | ! Arguments for non-cyclic boundary conditions added to argument list of |
---|
22 | ! routine exchange_horiz, |
---|
23 | ! ql calculated for the ghost points, exchange of ghost points removed |
---|
24 | ! |
---|
25 | ! Revision 1.1 2000/04/13 14:50:45 schroeter |
---|
26 | ! Initial revision |
---|
27 | ! |
---|
28 | ! |
---|
29 | ! |
---|
30 | ! Description: |
---|
31 | ! ------------ |
---|
32 | ! Calculation of the liquid water content (0%-or-100%-scheme) |
---|
33 | !------------------------------------------------------------------------------! |
---|
34 | |
---|
35 | |
---|
36 | USE arrays_3d |
---|
37 | USE cloud_parameters |
---|
38 | USE constants |
---|
39 | USE grid_variables |
---|
40 | USE indices |
---|
41 | USE pegrid |
---|
42 | |
---|
43 | IMPLICIT NONE |
---|
44 | |
---|
45 | INTEGER :: i, j, k |
---|
46 | |
---|
47 | REAL :: alpha, e_s, q_s, t_l |
---|
48 | |
---|
49 | DO i = nxl-1, nxr+1 |
---|
50 | DO j = nys-1, nyn+1 |
---|
51 | DO k = nzb_2d(j,i)+1, nzt |
---|
52 | |
---|
53 | ! |
---|
54 | !-- Compute the liquid water temperature |
---|
55 | t_l = t_d_pt(k) * pt(k,j,i) |
---|
56 | |
---|
57 | ! |
---|
58 | !-- Compute saturation water vapor pressure at t_l |
---|
59 | e_s = 610.78 * EXP( 17.269 * ( t_l - 273.16 ) / & |
---|
60 | ( t_l - 35.86 ) ) |
---|
61 | |
---|
62 | ! |
---|
63 | !-- Compute approximation of saturation humidity |
---|
64 | q_s = 0.622 * e_s / ( hyp(k) - 0.378 * e_s ) |
---|
65 | |
---|
66 | ! |
---|
67 | !-- Correction factor |
---|
68 | alpha = 0.622 * l_d_r * l_d_cp / ( t_l * t_l ) |
---|
69 | |
---|
70 | ! |
---|
71 | !-- Correction of the approximated value |
---|
72 | !-- (see: Cuijpers + Duynkerke, 1993, JAS, 23) |
---|
73 | q_s = q_s * ( 1.0 + alpha * q(k,j,i) ) / ( 1.0 + alpha * q_s ) |
---|
74 | |
---|
75 | ! |
---|
76 | !-- Compute the liquid water content |
---|
77 | IF ( ( q(k,j,i) - q_s ) > 0.0 ) THEN |
---|
78 | ql(k,j,i) = q(k,j,i) - q_s |
---|
79 | ELSE |
---|
80 | ql(k,j,i) = 0.0 |
---|
81 | ENDIF |
---|
82 | |
---|
83 | ENDDO |
---|
84 | ENDDO |
---|
85 | ENDDO |
---|
86 | |
---|
87 | END SUBROUTINE calc_liquid_water_content |
---|