Surface output parameters














PALM allows the output of instantaneous data as well as of temporally averaged surface data, i.e. from horizontally and vertically orientated surfaces. These data can be further processed into Paraview readable VTK files, in order to visualize surface properties such as surface temperature or radiation balance, etc.. Output is written into binary files.

Please note, in order to visualize surface data with Paraview, a postprocessing tool is required in order to convert into VTK files. This postprocessing tool will be provided soon.

NAMELIST group name: surface_output_parameters


Parameter Name FORTRAN
Type
Default
Value
Explanation

averaging_interval_surf

R

value of averaging_interval

Averaging interval for surface output data (in s). In any case, averaging_interval_surf <= dt_dosurf_av must hold. If an interval is defined, then by default the average is calculated from the data values of all time steps lying within this interval.

data_output_surf

C * 300 (100)

' '

Quantities for which surface data shall be be output. PALM allows the output of instantaneous data as well as of temporally averaged data which is steered by the string '_av' assigned to this parameter (see data_output for more explanation). For example, data_output_surf = 'shf', 'shf_av', will output instantaneous as well as time-averaged data of surface sensible heat flux at all surface elements.

Surface data for all surfaces elements on the processor subdomain is output in a separate NetCDF file. Further, additional information about polygons and vertices defining the surface elements are output. This information enables to create VTK files with a post-processor (not available yet) which can be read by this visualization software PARAVIEW.

The following quantities are available for output:

Quantity name Meaning Unit Remarks
shf surface sensible heat fluxK m / s
qsws surface latent heat fluxkg m / ( kg s )

... (more will follow)

dt_dosurf

R

value of dt_data_output

Temporal interval at which instantaneous surface data shall be output (in s). Output can be skipped at the beginning of a simulation using parameter skip_time_dosurf, which has zero value by default.

dt_dosurf_av

R

value of dt_dosurf

Temporal interval at which time averaged surface data shall be output (in s). Output can be skipped at the beginning of a simulation using parameter skip_time_dosurf_av, which has zero value by default.

skip_time_dosurf

R

0.0

No surface data output before this interval has passed (in s). This parameter causes that surface data output activities are starting not before this interval (counting from the beginning of the simulation, t=0) has passed.

skip_time_dosurf_av

R

0.0

No surfave data output of averaged variables before this interval has passed (in s). This parameter causes that averaged surface data output activities are starting not before this interval (counting from the beginning of the simulation, t=0) has passed.