Version 15 (modified by weinreis, 15 years ago) (diff)

--

Runtime parameters

Output steering

Run steering



Output steering:

Parameter Name FORTRAN Type Default Value Explanation

averaging_interval

R

0.0

Averaging interval for all output of temporally averaged data (in s).

This parameter defines the time interval length for temporally averaged data (vertical profiles, spectra, 2d cross-sections, 3d volume data). By default, data are not subject to temporal averaging. The interval length is limited by the parameter dt_data_output_av. In any case, averaging_interval <= dt_data_output_av must hold.

If an interval is defined, then by default the average is calculated from the data values of all timesteps lying within this interval. The number of time levels entering into the average can be reduced with the parameter dt_averaging_input?.

If an averaging interval can not be completed at the end of a run, it will be finished at the beginning of the next restart run. Thus for restart runs, averaging intervals do not necessarily begin at the beginning of the run.

Parameters averaging_interval_pr and averaging_interval_sp? can be used to define different averaging intervals for vertical profile data and spectra, respectively.

averaging_interval_pr

R

value of averaging_interval

Averaging interval for output of vertical profiles to local file DATA_1D_PR_NETCDF? (in s).

If this parameter is given a non-zero value, temporally averaged vertical profile data are output. By default, profile data data are not subject to temporal averaging. The interval length is limited by the parameter dt_dopr?. In any case averaging_interval_pr <= dt_dopr must hold.

If an interval is defined, then by default the average is calculated from the data values of all timesteps lying within this interval. The number of time levels entering into the average can be reduced with the parameter dt_averaging_input_pr?.

If an averaging interval can not be completed at the end of a run, it will be finished at the beginning of the next restart run. Thus for restart runs, averaging intervals do not necessarily begin at the beginning of the run.

dt_data_output_av

R

0.0



Run steering:

Parameter Name Type Default Value Explanation

call_psolver_at_all_substeps

L

.T.

Switch to steer the call of the pressure solver.

In order to speed-up performance, the Poisson equation for perturbation pressure (see psolver?) can be called only at the last substep of multistep Runge-Kutta timestep schemes (see timestep_scheme?) by setting call_psolver_at_all_substeps = .F.. In many cases, this sufficiently reduces the divergence of the velocity field. Nevertheless, small-scale ripples (2-delta-x) may occur. In this case and in case of non-cyclic lateral boundary conditions, call_psolver_at_all_timesteps = .T. should be used.

cfl_factor

R

0.1, 0.8 or 0.9 (see right)

Time step limiting factor.

In the model, the maximum allowed time step according to CFL and diffusion-criterion dt_max? is reduced by dt = dt_max * cfl_factor in order to avoid stability problems which may arise in the vicinity of the maximum allowed timestep. The condition 0.0 < cfl_factor < 1.0 applies.

call_psolver_at_all_substeps

L

.T.

call_psolver_at_all_substeps

L

.T.

call_psolver_at_all_substeps

L

.T.

call_psolver_at_all_substeps

L