Changes between Version 7 and Version 8 of doc/app/runtime_parameters
- Timestamp:
- Sep 13, 2010 11:17:16 AM (15 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
doc/app/runtime_parameters
v7 v8 18 18 Averaging interval for all output of temporally averaged data (in s).\\\\ 19 19 This parameter defines the time interval length for temporally averaged data (vertical profiles, spectra, 2d cross-sections, 3d volume data). By default, data are not subject to temporal averaging. The interval length is limited by the parameter 20 [#dt_data_output_av dt_data_output_av]. In any case, '''averaging_interval <=dt_data_output_av''' must hold.\\\\20 [#dt_data_output_av dt_data_output_av]. In any case, '''averaging_interval<=dt_data_output_av''' must hold.\\\\ 21 21 If an interval is defined, then by default the average is calculated from the data values of all timesteps lying within this interval. The number of time levels entering into the average can be reduced with the parameter [#dt_averaging_input dt_averaging_input].\\\\ 22 22 If an averaging interval can not be completed at the end of a run, it will be finished at the beginning of the next restart run. Thus for restart runs, averaging intervals do not necessarily begin at the beginning of the run.\\\\