Changes between Version 830 and Version 831 of doc/app/errmsg
- Timestamp:
- Nov 2, 2022 12:23:48 PM (2 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
doc/app/errmsg
v830 v831 224 224 ||[=#PA0182 PA0182] ||no output provided for: ... || There is no 3D data output available for the selected variable. Please check your variable list in your [../runtime_parameters#data_output data_output] and [../user_parameters#data_output_user data_output_user] parameter for correct spelling. || 225 225 ||[=#PA0183 PA0183] ||end_time of the simulation exceeds the time dimension in the dynamic input file || time dimension in dynamic input file must cover the entire simulation time. || 226 ||[=#PA0184 PA0184] || unknown recycling method: ... || Allowed input for recycling_method is 'turbulent_fluctuation', 'absolute_value', or 'absolute_value_thermodynamic'. ||226 ||[=#PA0184 PA0184] || unknown turbulent inflow method: ... || Allowed input for the turbulence recycling method is 'read_from_file' (not before Nov. 2022), 'recycle_turbulent_fluctuation', 'recycle_absolute_value', or 'recycle_absolute_value_thermodynamic'. || 227 227 ||[=#PA0185 PA0185] || data_output_pr = s*2 is not implemented for passive_scalar = .FALSE. ||The listed entry s*2 in the parameter file under [../runtime_parameters#data_output_pr data_output_pr] is only available for [../initialization_parameters#passive_scalar passive_scalar]= .T.. || 228 228 ||[=#PA0186 PA0186] || no spectra data available || This message occurs if the {{{data_output_spectra}}} routine is called but no spectra data was calculated through the routine {{{calc_spectra}}}. Check your [../spectra_parameters#SpectraParameters spectra settings] in the parameter file. ||