Changes between Version 505 and Version 506 of doc/app/errmsg


Ignore:
Timestamp:
May 22, 2018 9:06:38 AM (6 years ago)
Author:
Giersch
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • doc/app/errmsg

    v505 v506  
    4040||[=#PA0015 PA0015]   || Using synthetic turbulence generator requires initializing_actions = "set_constant_profiles" or "read_restart_data" || When switching on the synthetic turbulence generator by setting use_synthetic_turbulence_generator = .TRUE., PALM has to be initialized using either constant profiles ([../inipar#initializing_actions initializing_actions] = "set_constant_profiles") or loading data from a previous run ([../inipar#initializing_actions initializing_actions] = "read_restart_data"). Other initialization actions do not support the synthetic turbulence generator. ||
    4141||[=#PA0016 PA0016]   ||unknown solver for perturbation pressure: psolver = "..."   ||See parameter [../inipar#psolver psolver] for allowed values, and correct your parameter file. ||
    42 ||[=#PA0017 PA0017]   || ||  ||
    43 ||[=#PA0018 PA0018]   ||ros_count > 5 in Rosenbrock method  || The Rosenbrock method is used if curvature and solution effects are included in the calculation of cloud droplet growth due to condensation (see [../parpar#curvature_solution_effects curvature_solution_effects]). This algorithm may lead to unreasonable results, if the external conditions, especially the supersaturation, significantly changes between two PALM time steps. In that case, the algorithm will be carried out again with a smaller internal time step. The limits, which decide weather a result is reasonable or not, are only tested for a certain range of relative humidities and cloud droplet sizes. If this error appears, the result after 5 recalculations of the Rosenbrock algorithm is still regarded as unreasonable. Thus the limiting values may not be suitable for the current conditions and need to be adjusted in PALM's source code (see file [source:palm/trunk/SOURCE/lpm_droplet_condensation.f90 lpm_doplet_condensation.f90] in the repository). ||
    44 ||[=#PA0019 PA0019]   ||   ||message number is unused ||
     42||[=#PA0017 PA0017]   || ||message number is unused  ||
     43||[=#PA0018 PA0018]   || ||message number is unused ||
     44||[=#PA0019 PA0019]   || unknown surface type: surface_type = "..."  ||See parameter [../lsmpar#surface_type surface_type] for allowed values, and appropriately correct your parameter file. ||
    4545||[=#PA0020 PA0020]   ||unknown multigrid cycle: cycle_mg = "..."   ||See parameter [../inipar#cycle_mg cycle_mg] for allowed values, and appropriately correct your parameter file. ||
    4646||[=#PA0021 PA0021]   ||unknown fft-algorithm: fft_method = "..."   ||See parameter [../inipar#fft_method fft_method] for allowed values, and appropriately correct your parameter file. ||