326 | | ||[=#PA0286 PA0286] ||version mismatch concerning data from prior run version on file = "..." version in program = "..." || || |
327 | | ||[=#PA0287 PA0287] ||problem with index bound nxl on restart file "..." nxl = ... but it should be = ... from the index bound information array || || |
328 | | ||[=#PA0288 PA0288] ||problem with index bound nxr on restart file "..." nxr = ... but it should be = ... from the index bound information array || || |
329 | | ||[=#PA0289 PA0289] ||problem with index bound nys on restart file "..." nys = ... but it should be = ... from the index bound information array || || |
330 | | ||[=#PA0290 PA0290] ||problem with index bound nyn on restart file "..." nyn = ... but it should be = ... from the index bound information array || || |
331 | | ||[=#PA0291 PA0201] ||mismatch between actual data and data from prior run on PE ... nzb on file = ... nzb = ... || The vertical extent of the model domain must be the same in precursor and main run. In this case, there is a mismatch in the respective topography. See documentation of [../examples/turbinf tubulent inflow] for detailed information on the use of restart data for precursor runs. || |
332 | | ||[=#PA0292 PA0292] ||mismatch between actual data and data from prior run on PE ... nzt on file = ... nzt = ... || The vertical extent of the model domain must be the same in precursor and main run. See documentation of [../examples/turbinf tubulent inflow] for detailed information on the use of restart data for precursor runs. || |
| 326 | ||[=#PA0286 PA0286] ||version mismatch concerning data from prior run version on file = "..." version in program = "..." || The precursor run was carried out with a different version than the main run. Repeat the precurser with the current version or carry out the main run with the same version as the precursor. || |
| 327 | ||[=#PA0287 PA0287] ||problem with index bound nxl on restart file "..." nxl = ... but it should be = ... from the index bound information array ||The processor grid was changed between this and the previous run. See documentation of [../examples/turbinf tubulent inflow] for detailed information on the use of restart data for precursor runs. || |
| 328 | ||[=#PA0288 PA0288] ||problem with index bound nxr on restart file "..." nxr = ... but it should be = ... from the index bound information array || The processor grid was changed between this and the previous run. See documentation of [../examples/turbinf tubulent inflow] for detailed information on the use of restart data for precursor runs. || |
| 329 | ||[=#PA0289 PA0289] ||problem with index bound nys on restart file "..." nys = ... but it should be = ... from the index bound information array || The processor grid was changed between this and the previous run. See documentation of [../examples/turbinf tubulent inflow] for detailed information on the use of restart data for precursor runs. || |
| 330 | ||[=#PA0290 PA0290] ||problem with index bound nyn on restart file "..." nyn = ... but it should be = ... from the index bound information array || The processor grid was changed between this and the previous run. See documentation of [../examples/turbinf tubulent inflow] for detailed information on the use of restart data for precursor runs. || |
| 331 | ||[=#PA0291 PA0201] ||mismatch between actual data and data from prior run on PE ... \\nzb on file = ... \\nzb = ... || The vertical extent of the model domain must be the same in precursor and main run. In this case, there is a mismatch in the respective topography. See documentation of [../examples/turbinf tubulent inflow] for detailed information on the use of restart data for precursor runs. || |
| 332 | ||[=#PA0292 PA0292] ||mismatch between actual data and data from prior run on PE ... \\nzt on file = ... \\nzt = ... || The vertical extent of the model domain must be the same in precursor and main run. See documentation of [../examples/turbinf tubulent inflow] for detailed information on the use of restart data for precursor runs. || |