173 | | ||[=#PA0131 PA0131] ||inflow_disturbance_begin out of range || Jens || |
174 | | ||[=#PA0132 PA0132] ||inflow_disturbance_end out of range || Jens || |
| 173 | ||[=#PA0131 PA0131] ||inflow_disturbance_begin out of range || The parameter [../inipar#inflow_disturbance_begin inflow_disturbance_begin] gives the number of grid points (counted horizontally from the inflow) from which on perturbations are imposed on the horizontal velocity field. This value must not be smaller than zero or larger than nx (in case of non-cyclic lateral boundary conditions along the x-direction) or ny (in case of non-cyclic lateral boundary conditions along the y-direction). || |
| 174 | ||[=#PA0132 PA0132] ||inflow_disturbance_end out of range || The parameter [../inipar#inflow_disturbance_end inflow_disturbance_end] gives the number of grid points (counted horizontally from the inflow) up to which perturbations are imposed on the horizontal velocity field. This value must not be smaller than zero or larger than nx (in case of non-cyclic lateral boundary conditions along the x-direction) or ny (in case of non-cyclic lateral boundary conditions along the y-direction). || |