= Static driver look-up tables = All ''_pars'' variables are of NC_FLOAT type. Note that ''[#building_pars building_pars]'' and ''[#building_surface_pars building_surface_pars]'' will undergo major revision in near future. == [#albedo_pars ''albedo_pars(nalbedo_pars,y,x)''] ||='''nalbedo_pars''' =||='''Units''' =||='''Description''' =|| || 0|| 1 || Broadband albedo of surface elements (wall fraction in case of building) at (y,x). || || 1|| 1 || Only for buildings. Longwave albedo of wall fraction at (y,x). || || 2|| 1 || Only for buildings. Shortwave albedo of wall fraction at (y,x). || || 3|| 1 || Only for buildings. Longwave albedo of green fraction at (y,x). || || 4|| 1 || Only for buildings. Shortwave albedo of green fraction at (y,x). || || 5|| 1 || Only for buildings. Longwave albedo of window fraction at (y,x). || || 6|| 1 || Only for buildings. Shortwave albedo of window fraction at (y,x). || == [#building_pars ''building_pars(nbuilding_pars,y,x)''] [[span(style=color: #FF0000, Please note, buildings_pars will undergo a major revision soon. )]] ||='''nbuilding_pars''' =||='''Units''' =||='''Description''' =|| || 0|| 1 || Wall fraction above the ground floor level || || 1|| 1 || Window fraction above the ground floor level || || 2|| 1 || Green fraction on wall above the ground floor level || || 3|| 1 || Green fraction on roof || || 4|| m²/m² || Leaf area index of green fraction on roof || || 5|| m²/m² || Leaf area index of green fraction on wall above the ground floor level || || 6|| J/m²/K || Heat capacity of wall layer 1 above the ground floor level || || 7|| J/m²/K || Heat capacity of wall layer 2 above the ground floor level || || 8|| J/m²/K || Heat capacity of wall layer 3 above the ground floor level || || 9|| W/m/K || Thermal conductivity of wall layer 1 above the ground floor level || || 10|| W/m/K || Thermal conductivity of wall layer 2 above the ground floor level || || 11|| W/m/K || Thermal conductivity of wall layer 3 above the ground floor level || || 12|| K || Indoor target summer temperature || || 13|| K || Indoor target winter temperature || || 14|| 1 || Emissivity of wall fraction above the ground floor level || || 15|| 1 || Emissivity of green fraction above the ground floor level || || 16|| 1 || Emissivity of window fraction above the ground floor level || || 17|| 1 || Transmissivity of window fraction above the ground floor level || || 18|| m || Roughness length for momentum above the ground floor level || || 19|| m || Roughness length for heat above the ground floor level || || 20|| m || Ground floor height || || 21|| 1 || Ground floor wall fraction || || 22|| 1 || Ground floor window fraction || || 23|| 1 || Ground floor green fraction on wall || || 24|| 1 || Ground floor green fraction on roof || || 25|| m²/m² || Ground floor leaf area index of green fraction (wall) || || 26|| J/m²/K || Ground floor heat capacity of wall layer 1 || || 27|| J/m²/K || Ground floor heat capacity of wall layer 2 || || 28|| J/m²/K || Ground floor heat capacity of wall layer 3 || || 29|| W/m/K || Ground floor thermal conductivity of wall layer 1 || || 30|| W/m/K || Ground floor thermal conductivity of wall layer 2 || || 31|| W/m/K || Ground floor thermal conductivity of wall layer 3 || || 32|| 1 || Ground floor emissivity of wall fraction || || 33|| 1 || Ground floor emissivity of green fraction || || 34|| 1 || Ground floor emissivity of window fraction || || 35|| 1 || Ground floor transmissivity of window fraction || || 36|| m || Ground floor roughness length for momentum || || 37|| m || Ground floor roughness length for heat || || 38|| 1 || albedo\_type of wall fraction || || 39|| 1 || albedo\_type of green fraction || || 40|| 1 || albedo\_type of window fraction || || 41|| m || Wall depth of layer 1 || || 42|| m || Wall depth of layer 2 || || 43|| m || Wall depth of layer 3 || || 44|| m || Wall depth of layer 4 || || 45|| J/m²/K || Surface wall heat capacity || || 46|| W/m²/K || Surface wall conductivity || || 47|| J/m²/K || Heat capacity of window surface || || 48|| J/m²/K || Heat capacity of green surface || || 49|| W/m/K || Thermal conductivity of window surface || || 50|| W/m/K || Thermal conductivity of green surface || || 51*|| 1 || Wall fraction ground plate || || 52*|| m || depth of ground plate wall layer 1 || || 53*|| m || depth of ground plate wall layer 2 || || 54*|| m || depth of ground plate wall layer 3 || || 55*|| m || depth of ground plate wall layer 4 || || 56*|| J/m²/K || Heat capacity of ground plate wall layers 1 || || 57*|| J/m²/K || Heat capacity of ground plate wall layer 2 || || 58*|| J/m²/K || Heat capacity of ground plate wall layer 3 || || 59*|| W/m/K || Thermal conductivity of ground plate wall layers 1 || || 60*|| W/m/K || Thermal conductivity of ground plate wall layer 2 || || 61*|| W/m/K || Thermal conductivity of ground plate wall layer 3 || || 62|| m || depth of first floor wall layer 1 || || 63|| m || depth of first floor wall layer 2 || || 64|| m || depth of first floor wall layer 3 || || 65|| m || depth of first floor wall layer 4 || || 66|| 1 || Albedo of ground floor wall || || 67|| m || depth of first floor window layer 1 || || 68|| m || depth of first floor window layer 2 || || 69|| m || depth of first floor window layer 3 || || 70|| m || depth of first floor window layer 4 || || 71|| J/m²/K || Heat capacity of first floor window layers 1 || || 72|| J/m²/K || Heat capacity of first floor window layer 2 || || 73|| J/m²/K || Heat capacity of first floor window layer 3 || || 74|| W/m/K || Thermal conductivity of first floor window layers 1 || || 75|| W/m/K || Thermal conductivity of first floor window layer 2 || || 76|| W/m/K || Thermal conductivity of first floor window layer 3 || || 77|| 1 || Albedo of first floor window || || 78|| 1 || Albedo of first floor green surface || || 79|| m || depth of standard floor window layer 1 || || 80|| m || depth of standard floor window layer 2 || || 81|| m || depth of standard floor window layer 3 || || 82|| m || depth of standard floor window layer 4 || || 83|| J/m²/K || Heat capacity of standard floor wall layers 1 || || 84|| J/m²/K || Heat capacity of standard floor wall layer 2 || || 85|| J/m²/K || Heat capacity of standard floor wall layer 3 || || 86|| W/m/K || Thermal conductivity of standard floor wall layers 1 || || 87|| W/m/K || Thermal conductivity of standard floor wall layer 2 || || 88|| W/m/K || Thermal conductivity of standard floor wall layer 3 || || 89|| 1 || Wall fraction of roof || || 90|| m || depth of roof layer 1 || || 91|| m || depth of roof layer 2 || || 92|| m || depth of roof layer 3 || || 93|| m || depth of roof layer 4 || || 94|| J/m²/K || Heat capacity of roof layers 1 || || 95|| J/m²/K || Heat capacity of roof layer 2 || || 96|| J/m²/K || Heat capacity of roof layer 3 || || 97|| W/m/K || Thermal conductivity of roof layers 1 || || 98|| W/m/K || Thermal conductivity of roof layer 2 || || 99|| W/m/K || Thermal conductivity of roof layer 3 || || 100|| 1 || Emissivity of roof || || 101|| 1 || Albedo of roof || || 102|| 1 || Window fraction of roof || || 103|| m || depth of roof window layer 1 || || 104|| m || depth of roof window layer 2 || || 105|| m || depth of roof window layer 3 || || 106|| m || depth of roof window layer 4 || || 107|| J/m²/K || Heat capacity of window layers 1 || || 108|| J/m²/K || Heat capacity of window layer 2 || || 109|| J/m²/K || Heat capacity of window layer 3 || || 110|| W/m/K || Thermal conductivity of window layers 1 || || 111|| W/m/K || Thermal conductivity of window layer 2 || || 112|| W/m/K || Thermal conductivity of window layer 3 || || 113|| 1 || Emissivity of roof window || || 114|| 1 || Transmissivity of roof window || || 115|| 1 || Albedo of roof window || || 116|| 1 || Emissivity of roof green surface || || 117|| 1 || Albedo of roof green surface || || 118|| 1 || Type of green roof (=2 extensive, =1 intensive)) || || 119|| 1 || Shading factor || || 120|| 1 || Window g-value || || 121|| W/m²/K || Window u-value || || 122|| 1/h || Basic air flow without occupancy of room || || 123|| 1/h || Additional air flow during occupancy of room || || 124|| 1 || Heat recovery efficiency || || 125|| 1 || Factor for mass specific active surface || || 126|| J/m²/K || Factor for inner heat storage of building zone || || 127|| 1 || Ratio of internal surface to floor area || || 128|| W || Maximum heating capacity || || 129|| W || Maximum cooling capacity || || 130|| W/m² || Additional internal heat gains during occupancy of room || || 131|| W/m² || Basic internal heat gains without occupancy of room || || 132|| m || Storey height || || 133*|| m || Ceiling construction height || || 134|| 1 || Technology heating factor for anthropogenic heat losses || || 135|| 1 || Technology cooling factor for anthropogenic heat losses || || 136|| J/m²/K || Heat capacity of wall layer 4 above the ground floor level || || 137|| W/m/K || Thermal conductivity of wall layer 4 above the ground floor level || || 138|| J/m²/K || Heat capacity of wall layer 4 at the ground floor level || || 139|| W/m/K || Thermal conductivity of wall layer 4 at the ground floor level || || 140*|| J/m²/K || Heat capacity of wall layer 4 at ground plate || || 141*|| W/m/K || Thermal conductivity of wall layer 4 at ground plate || || 142|| J/m²/K || Heat capacity of window layer 4 at the ground floor level || || 143|| W/m/K || Thermal conductivity of window layer 4 at the ground floor level || || 144|| J/m²/K || Heat capacity of window layer 4 above the ground floor level || || 145|| W/m/K || Thermal conductivity of window layer 4 above the ground floor level || || 146|| J/m²/K || Heat capacity of wall layer 4 at roof || || 147|| W/m/K || Thermal conductivity of wall layer 4 at roof || || 148|| J/m²/K || Heat capacity of window layer 4 at roof || || 149|| W/m/K || Thermal conductivity of window layer 4 at roof || (*) are not processed by PALM at the moment. == [#building_surface_pars ''building_surface_pars(nbuilding_surface_pars,ns)''] ||='''nbuilding_surface_pars''' =||='''Units''' =||='''Description''' =|| || 0|| 1 || Wall fraction || || 1|| 1 || Window fraction || || 2|| 1 || Green fraction on wall || || 3|| 1 || Green fraction on roof || || 4|| m²/m² || Leaf area index of green fraction || || 5|| J/m²/K || Heat capacity of wall layer 1 || || 6|| J/m²/K || Heat capacity of wall layer 2 || || 7|| J/m²/K || Heat capacity of wall layer 3 || || 8|| W/m/K || Thermal conductivity of wall layer 1 || || 9|| W/m/K || Thermal conductivity of wall layer 2 || || 10|| W/m/K || Thermal conductivity of wall layer 3 || || 11|| K || Indoor target summer temperature || || 12|| K || Indoor target winter temperature || || 13|| 1 || Emissivity of wall fraction || || 14|| 1 || Emissivity of green fraction || || 15|| 1 || Emissivity of window fraction || || 16|| 1 || Transmissivity of window fraction || || 17|| m || Roughness length for momentum || || 18|| m || Roughness length for heat || || 19|| 1 || Broadband albedo of wall fraction || || 20|| 1 || Longwave albedo of wall fraction || || 21|| 1 || Shortwave albedo of wall fraction || || 22|| 1 || Broadband albedo of window fraction || || 23|| 1 || Longwave albedo of window fraction || || 24|| 1 || Shortwave albedo of window fraction || || 25|| 1 || Broadband albedo of green fraction || || 26|| 1 || Longwave albedo of green fraction || || 27|| 1 || Shorwave albedo of green fraction || == [#pavement_pars ''pavement_pars(npavement_pars,y,x)''] ||='''npavement_pars''' =||='''Units''' =||='''Description''' =|| || 0|| m || Roughness length for momentum || || 1|| m || Roughness length for heat || || 2|| 1 || ''[../#albedo_type albedo_type]'' || || 3|| 1 || Surface emissivity || == [#pavement_subsurface_pars ''pavement_subsurface_pars(npavement_subsurface_pars,zsoil,y,x)''] ||='''npavement_subsurface_pars''' =||='''Units''' =||='''Description''' =|| || 0|| W/m/K || Thermal conductivity of the respective soil layer || || 1|| J/m³/K || Volumetric heat capacity of the respective soil layer || == [#soil_pars ''soil_pars(nsoil_pars,(zsoil,)y,x)''] ||='''nsoil_pars''' =||='''Units''' =||='''Description''' =|| || 0|| 1 || Van Genuchten parameter '''α''' || || 1|| 1 || Van Genuchten parameter '''l''' || || 2|| 1 || Van Genuchten parameter '''n''' || || 3|| m/s || Saturation hydraulic conductivity || || 4|| m³/m³ || Saturation soil moisture || || 5|| m³/m³ || Field capacity || || 6|| m³/m³ || Wilting point || || 7|| m³/m³ || Residual moisture || == [#vegetation_pars ''vegetation_pars(nvegetation_pars,y,x)''] ||='''nvegetation_pars''' =||='''Units''' =||='''Descripton''' =|| || 0|| s/m || Minimum canopy resistance || || 1|| m²/m² || Leaf area index || || 2|| 1 || Vegetation coverage || || 3|| 1/hPa || Canopy resistance coefficient || || 4|| m || Roughness length for momentum || || 5|| m || Roughness length for heat || || 6|| W/m²/K || Skin lacer heat conductivity (stable conditions) || || 7|| W/m²/K || Skin layer heat conductivity (unstable conditions) || || 8|| 1 || Fraction of incoming shortwave radiation transmitted directly to the soil (not implemented yet) || || 9|| J/m²/K || Heat capacity of the surface || || 10|| 1 || ''[../#albedo_type albedo_type]'' || || 11|| 1 || Surface emissivity || == [#water_pars ''water_pars(nwater_pars,y,x)''] ||='''nwater_pars''' =||='''Units''' =||='''Description''' =|| || 0|| K || Water temperature || || 1|| m || Roughness length for momentum || || 2|| m || Roughness length for heat || || 3|| W/m²/K || Heat conductivity between skin layer and water (stable conditions) || || 4|| W/m²/K || Heat conductivity between skin layer and water (unstable conditions) || || 5|| 1 || ''[../#albedo_type albedo_type]'' || || 6|| 1 || Surface emissivity ||