Ignore:
Timestamp:
Jun 18, 2019 10:32:41 AM (2 years ago)
Author:
suehring
Message:

diagnostic output: Modularize diagnostic output, rename subroutines; formatting adjustments; allocate arrays only when required; add output of uu, vv, ww to enable variance calculation via temporal EC method; radiation: bugfix in masked data output; flow_statistics: Correct conversion to kinematic vertical scalar fluxes in case of pw-scheme and statistic regions

File:
1 edited

Legend:

Unmodified
Added
Removed
  • palm/trunk/SOURCE/palm.f90

    r4017 r4039  
    2525! -----------------
    2626! $Id$
     27! Rename subroutines in module for diagnostic quantities
     28!
     29! 4017 2019-06-06 12:16:46Z schwenkel
    2730! new module for calculation and output of diagnostic quantities added
    2831!
     
    305308
    306309    USE diagnostic_output_quantities_mod,                                      &
    307         ONLY:  diagnostic_output_quantities_calculate
     310        ONLY:  doq_calculate
    308311
    309312    USE indices,                                                               &
     
    559562!-- If required, output of initial arrays
    560563    IF ( do2d_at_begin )  THEN
    561        CALL diagnostic_output_quantities_calculate    !TODO, will be called twice
     564       CALL doq_calculate    !TODO, will be called twice
    562565
    563566       CALL data_output_2d( 'xy', 0 )
     
    567570
    568571    IF ( do3d_at_begin )  THEN
    569        CALL diagnostic_output_quantities_calculate    !TODO, will be called twice
     572       CALL doq_calculate    !TODO, will be called twice
    570573
    571574       CALL data_output_3d( 0 )
Note: See TracChangeset for help on using the changeset viewer.