source: palm/trunk/SOURCE/run_control.f90

Last change on this file was 4828, checked in by Giersch, 3 years ago

Copyright updated to year 2021, interface pmc_sort removed to accelarate the nesting code

  • Property svn:keywords set to Id
File size: 6.6 KB
Line 
1!> @file run_control.f90
2!--------------------------------------------------------------------------------------------------!
3! This file is part of the PALM model system.
4!
5! PALM is free software: you can redistribute it and/or modify it under the terms of the GNU General
6! Public License as published by the Free Software Foundation, either version 3 of the License, or
7! (at your option) any later version.
8!
9! PALM is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the
10! implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General
11! Public License for more details.
12!
13! You should have received a copy of the GNU General Public License along with PALM. If not, see
14! <http://www.gnu.org/licenses/>.
15!
16! Copyright 1997-2021 Leibniz Universitaet Hannover
17!--------------------------------------------------------------------------------------------------!
18!
19!
20! Current revisions:
21! -----------------
22!
23!
24! Former revisions:
25! -----------------
26! $Id: run_control.f90 4828 2021-01-05 11:21:41Z banzhafs $
27! File re-formatted to follow the PALM coding standard
28!
29!
30! 4360 2020-01-07 11:25:50Z suehring
31! Corrected "Former revisions" section
32!
33! 3655 2019-01-07 16:51:22Z knoop
34! Corrected "Former revisions" section
35!
36! Revision 1.1  1997/08/11 06:25:38  raasch
37! Initial revision
38!
39!
40! Description:
41! ------------
42!> Computation and output of run-control quantities
43!--------------------------------------------------------------------------------------------------!
44 SUBROUTINE run_control
45
46
47    USE cpulog,                                                                                    &
48        ONLY:  cpu_log,                                                                            &
49               log_point
50
51    USE control_parameters,                                                                        &
52        ONLY:  advected_distance_x,                                                                &
53               advected_distance_y,                                                                &
54               current_timestep_number,                                                            &
55               disturbance_created,                                                                &
56               dt_3d,                                                                              &
57               mgcycles,                                                                           &
58               run_control_header,                                                                 &
59               runnr,                                                                              &
60               simulated_time,                                                                     &
61               simulated_time_chr,                                                                 &
62               timestep_reason
63
64    USE indices,                                                                                   &
65        ONLY:  nzb
66
67    USE kinds
68
69    USE pegrid
70
71    USE statistics,                                                                                &
72        ONLY:  flow_statistics_called,                                                             &
73               hom,                                                                                &
74               pr_palm,                                                                            &
75               u_max,                                                                              &
76               u_max_ijk,                                                                          &
77               v_max,                                                                              &
78               v_max_ijk,                                                                          &
79               w_max,                                                                              &
80               w_max_ijk
81
82    IMPLICIT NONE
83
84    CHARACTER (LEN=1) ::  disturb_chr  !<
85
86!
87!-- If required, do statistics
88    IF ( .NOT. flow_statistics_called )  CALL flow_statistics
89
90!
91!-- Flow_statistics has its own cpu-time measurement
92    CALL cpu_log( log_point(11), 'run_control', 'start' )
93
94!
95!-- Output
96    IF ( myid == 0 )  THEN
97
98!
99!--    Check, whether file unit is already open (may have been opened in header before)
100       CALL check_open( 15 )
101
102!
103!--    If required, write header
104       IF ( .NOT. run_control_header )  THEN
105          WRITE ( 15, 100 )
106          run_control_header = .TRUE.
107       ENDIF
108
109!
110!--    If required, set disturbance flag
111       IF ( disturbance_created )  THEN
112          disturb_chr = 'D'
113       ELSE
114          disturb_chr = ' '
115       ENDIF
116       WRITE ( 15, 101 )  runnr, current_timestep_number, simulated_time_chr,                      &
117                          INT( ( simulated_time-INT( simulated_time ) ) * 100),                    &
118                          dt_3d, timestep_reason, u_max, disturb_chr, v_max, disturb_chr, w_max,   &
119                          hom(nzb,1,pr_palm,0), hom(nzb+8,1,pr_palm,0), hom(nzb+3,1,pr_palm,0),    &
120                          hom(nzb+6,1,pr_palm,0), hom(nzb+4,1,pr_palm,0), hom(nzb+5,1,pr_palm,0),  &
121                          hom(nzb+9,1,pr_palm,0), hom(nzb+10,1,pr_palm,0), u_max_ijk(1:3),         &
122                          v_max_ijk(1:3), w_max_ijk(1:3), advected_distance_x/1000.0_wp,           &
123                          advected_distance_y/1000.0_wp, mgcycles
124!
125!--    Write buffer contents to disc immediately
126       FLUSH( 15 )
127
128    ENDIF
129!
130!-- If required, reset disturbance flag. This has to be done outside the above
131!-- IF-loop, because the flag would otherwise only be reset on PE0
132    IF ( disturbance_created )  disturbance_created = .FALSE.
133
134    CALL cpu_log( log_point(11), 'run_control', 'stop' )
135
136!
137!-- Formats
138100 FORMAT (///'Run-control output:'/ &
139              &'------------------'// &
140          &'RUN  ITER. HH:MM:SS.SS    DT(E)     UMAX     VMAX     WMAX     U', &
141          &'*    W*      THETA*     Z_I     ENERG.   DISTENERG    DIVOLD    ', &
142          &' DIVNEW     UMAX(KJI)    VMAX(KJI)    WMAX(KJI)   ADVECX   ADVEC', &
143          &'Y   MGCYC'/                                                        &
144          &'----------------------------------------------------------------', &
145          &'----------------------------------------------------------------', &
146          &'----------------------------------------------------------------', &
147          &'---------')
148101 FORMAT (I3,1X,I6,1X,A8,'.',I2.2,1X,F8.4,A1,1X,F8.4,A1,F8.4,A1,F8.4,1X, F6.3,1X,F5.2,           &
149            2X,E10.3,2X,F6.0,1X,4(E10.3,1X),3(3(I4),1X),F8.3,1X,F8.3,5X,I3)
150
151 END SUBROUTINE run_control
Note: See TracBrowser for help on using the repository browser.