= Static driver look-up tables = All ''_pars'' variables are of NC_FLOAT type. == [#albedo_pars ''albedo_pars(nalbedo_pars,y,x)''] ||='''nalbedo_pars''' =||='''Units''' =||='''Description''' =|| ||0 || 1 || Broadband albedo of surface elements (wall fraction in case of building) at (y,x). || ||1 || 1 || Only for buildings. Longwave albedo of wall fraction at (y,x). || ||2 || 1 || Only for buildings. Shortwave albedo of wall fraction at (y,x). || ||3 || 1 || Only for buildings. Longwave albedo of green fraction at (y,x). || ||4 || 1 || Only for buildings. Shortwave albedo of green fraction at (y,x). || ||5 || 1 || Only for buildings. Longwave albedo of window fraction at (y,x). || ||6 || 1 || Only for buildings. Shortwave albedo of window fraction at (y,x). || == [#building_pars ''building_pars(nbuilding_pars,y,x)''] == [#building_surface_pars ''building_pars(nbuilding_surface_pars,ns)''] == [#pavement_pars ''pavement_pars(npavement_pars,y,x)''] == [#pavement_surface_pars ''pavement_surface_pars(npavement_surface_pars,y,x)''] == [#soil_pars ''soil_pars(nsoil_pars,(zsoil,)y,x)''] ||='''nsoil_pars''' =||='''Units''' =||='''Description''' =|| ||0 || 1 || Van Genuchten parameter '''α''' || ||1 || 1 || Van Genuchten parameter '''l''' || ||2 || 1 || Van Genuchten parameter '''n''' || ||3 || m/s || Saturation hydraulic conductivity || ||4 || m³/m³ || Saturation soil moisture || ||5 || m³/m³ || Field capacity || ||6 || m³/m³ || Wilting point || ||7 || m³/m³ || Residual moisture || == [#vegetation_pars ''vegetation_pars(nvegetation_pars,y,x)''] ||='''nvegetation_pars''' =||='''Units''' =||='''Descripton''' =|| || 0|| s/m || Minimum canopy resistance || || 1|| m³/m³ || Leaf area index || || 2|| 1 || Vegetation coverage || || 3|| 1/hPa || Canopy resistance coefficient || || 4|| m || Roughness length for momentum || || 5|| m || Roughness length for heat || || 6|| W/m²/K || Skin lacer heat conductivity (stable conditions) || || 7|| W/m²/K || Skin layer heat conductivity (unstable conditions) || || 8|| 1 || Fraction of incoming shortwave radiation transmitted directly to the soil (not implemented yet) || || 9|| J/m²/K || Heat capacity of the surface || || 10|| 1 || ''[../#albedo_type albedo_type]'' || || 11|| 1 || Surface emissivity || == [#water_pars ''water_pars(nwater_pars,y,x)''] ||='''nwater_pars''' =||='''Units''' =||='''Description''' =|| ||0 || K || Water temperature || ||1 || m || Roughness length for momentum || ||2 || m || Roughness length for heat || ||3 || W/m²/K || Heat conductivity between skin layer and water (stable conditions) || ||4 || W/m²/K || Heat conductivity between skin layer and water (unstable conditions) || ||5 || 1 || ''[../#albedo_type albedo_type]'' || ||6 || 1 || Surface emissivity ||