= Indoor model parameters = [[TracNav(doc/app/partoc|nocollapse)]] ==== [#steering Steering] ==== ==== [#string2 String2] ==== ==== [#string3 String3] ==== Since r31xx an indoor climate and energy demand model (abbreviation?) is available in PALM. The indoor climate and energy demand model based on the DIN EN ISO 13790 with simplfified hour-based procedure. This model is a equivalent circuit diagram of a three-point RC-model (5R1C). This module differ between indoor-air temperature an average temperature of indoor surfaces which make it possible to determine thermal comfort. \\\\ NAMELIST group name: [=#impar '''indoor_parameters''']\\ ---- \\\\ [=#steering '''Steering:]\\ ||='''Parameter Name''' =||='''[[../fortrantypes|FORTRAN]]\\[[../fortrantypes|Type]]''' =||='''Default\\Value''' =||='''Explanation''' =|| |---------------- {{{#!td style="vertical-align:top; width: 150px" [=#building_type '''building_type'''] }}} {{{#!td style="vertical-align:top; width: 50px" I }}} {{{#!td style="vertical-align:top; width: 75px" 1 }}} {{{#!td Index of used building type in building database.\\\\ The building database contain all necessary parameters for the calculation of the indoor climate model. }}} |---------------- {{{#!td style="vertical-align:top; width: 150px" [=#dt_indoor '''dt_indoor'''] }}} {{{#!td style="vertical-align:top; width: 50px" R }}} {{{#!td style="vertical-align:top; width: 75px" 3600.0 }}} {{{#!td Time interval for the call of the indoor model.\\\\ Here, a detailed description follows. }}} |---------------- {{{#!td style="vertical-align:top; width: 150px" [=#initial_indoor_temperature '''initial_indoor_temperature'''] }}} {{{#!td style="vertical-align:top; width: 50px" R }}} {{{#!td style="vertical-align:top; width: 75px" 293.15 }}} {{{#!td Initial indoor temperatures. }}} |----------------